EEWORLDEEWORLDEEWORLD

Part Number

Search

5962-9679801VCA

Description
IC DUAL COMPARATOR, 6800 uV OFFSET-MAX, CDIP14, CERAMIC, DIP-14, Comparator
CategoryAnalog mixed-signal IC    Amplifier circuit   
File Size142KB,4 Pages
ManufacturerDefense Supply Center Columbus
Download Datasheet Parametric View All

5962-9679801VCA Online Shopping

Suppliers Part Number Price MOQ In stock  
5962-9679801VCA - - View Buy Now

5962-9679801VCA Overview

IC DUAL COMPARATOR, 6800 uV OFFSET-MAX, CDIP14, CERAMIC, DIP-14, Comparator

5962-9679801VCA Parametric

Parameter NameAttribute value
MakerDefense Supply Center Columbus
Parts packaging codeDIP
package instructionDIP,
Contacts14
Reach Compliance Codeunknown
ECCN codeEAR99
Amplifier typeCOMPARATOR
Maximum average bias current (IIB)0.475 µA
Maximum input offset voltage6800 µV
JESD-30 codeR-GDIP-T14
JESD-609 codee0
Negative supply voltage upper limit-18 V
Nominal Negative Supply Voltage (Vsup)-15 V
Number of functions2
Number of terminals14
Maximum operating temperature125 °C
Minimum operating temperature-55 °C
Package body materialCERAMIC, GLASS-SEALED
encapsulated codeDIP
Package shapeRECTANGULAR
Package formIN-LINE
Certification statusQualified
Filter levelMIL-PRF-38535 Class V
Supply voltage upper limit18 V
Nominal supply voltage (Vsup)15 V
surface mountNO
technologyBIPOLAR
Temperature levelMILITARY
Terminal surfaceTIN LEAD
Terminal formTHROUGH-HOLE
Terminal locationDUAL
Application Note
SLVK047 – May 2020
Single-Event Effects (SEE) Confidence Interval
Calculations
ABSTRACT
This application note describes the methodology used to calculate confidence intervals for radiation-
hardened devices that exhibit few or zero radiation-induced events.
Contents
1
2
Introduction
...................................................................................................................
1
References
...................................................................................................................
3
List of Tables
1
Experimental Example Calculation of Mean-Fluence-to-Failure (MFTF) and,
σ
Using a 95% Confidence
Interval
........................................................................................................................
2
1
Introduction
Determining the SEE cross-section of robustly radiation-hardened devices becomes more difficult since
often few, or possibly even no events are observed during an entire exposure. Determining the cross-
section using an average event rate with standard deviation is no longer a viable option, and the common
practice of assuming a single error occurred at the conclusion of a null-result can end up in a greatly
underestimated cross-section.
In cases where observed events are rare or non-existent, the use of confidence intervals and the Chi-
Squared distribution is indicated. The Chi-Squared distribution is particularly well-suited for determining a
reliability level when the events occur at a constant rate. In the case of SEE testing where the ion events
are random in time and position within the irradiation area, it is expected that the event rate is independent
of time (presuming that parametric shifts induced by the total ionizing dose do not affect the failure rate),
so the use of Chi-Squared statistical techniques is valid (since events are rare an exponential or Poisson
distribution is usually used).
In a typical SEE experiment, the device-under-test (DUT) is exposed to a known, fixed fluence (ions/cm
2
)
while the DUT is monitored for events. This is analogous to fixed-time reliability testing and, more
specifically, time-terminated testing, where the reliability test is terminated after a fixed amount of time
whether or not a failure has occurred (in the case of SEE tests, fluence is substituted for time and hence it
is a fixed fluence test) [1]. Calculating a confidence interval specifically provides a range of values which is
likely to contain the parameter of interest (the actual number of events/fluence). Confidence intervals are
constructed at a specific confidence level. For example, a 95% confidence level implies that if a given
number of units was sampled numerous times and a confidence interval was estimated for each test, the
resulting set of confidence intervals would bracket the true population parameter in about 95% of the
cases.
To estimate the cross-section from a null-result (no events observed for a given fluence) with a confidence
interval, start with the standard reliability determination of lower-bound (minimum) mean-time-to-failure for
fixed-time testing (an exponential distribution is assumed):
SLVK047 – May 2020
Submit Documentation Feedback
Single-Event Effects Confidence Interval Calculations
Copyright © 2020, Texas Instruments Incorporated
1

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1831  617  2682  1300  1873  37  13  54  27  38 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号