EEWORLDEEWORLDEEWORLD

Part Number

Search

VE-M42-EW

Description
DC-DC Regulated Power Supply Module, 1 Output, 100W, Hybrid,
CategoryPower/power management    The power supply circuit   
File Size78KB,4 Pages
ManufacturerVICOR
Websitehttp://www.vicorpower.com/
Environmental Compliance  
Download Datasheet Parametric View All

VE-M42-EW Overview

DC-DC Regulated Power Supply Module, 1 Output, 100W, Hybrid,

VE-M42-EW Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerVICOR
package instruction,
Reach Compliance Codecompliant
ECCN codeEAR99
Analog Integrated Circuits - Other TypesDC-DC REGULATED POWER SUPPLY MODULE
Maximum input voltage100 V
Minimum input voltage55 V
Nominal input voltage72 V
JESD-30 codeR-XDFM-P9
Maximum load regulation0.5%
Number of functions1
Output times1
Number of terminals9
Maximum operating temperature85 °C
Minimum operating temperature-10 °C
Maximum output voltage16.5 V
Minimum output voltage13.5 V
Nominal output voltage15 V
Package body materialUNSPECIFIED
Package shapeRECTANGULAR
Package formFLANGE MOUNT
Peak Reflow Temperature (Celsius)NOT SPECIFIED
Certification statusNot Qualified
surface mountNO
technologyHYBRID
Temperature levelOTHER
Terminal formPIN/PEG
Terminal locationDUAL
Maximum time at peak reflow temperatureNOT SPECIFIED
Maximum total power output100 W
Fine-tuning/adjustable outputYES
12
1-800-735-6200
Mega Module &
Mega Module Jr.
Family
25 to 600 Watts
DC-DC Converters
Single, Dual,
Triple Output
Chassis Mount
Features
s
s
s
s
s
s
Inputs: 10 to 400Vdc
Any Output, 1 to 95Vdc
UL, CSA, TÜV, VDE, BABT
80-90% Efficiency (Typical)
Up to 27W/Cubic Inch
1 Up
2.58" x 2.5" x 0.62" (Junior)
4.9" x 2.5" x 0.62" (Full Size)
2 Up
2.58" x 4.9" x 0.62" (Junior)
4.9" x 4.9" x 0.62" (Full Size)
3 Up
2.58" x 7.3" x 0.62" (Junior)
4.9" x 7.3" x 0.62" (Full Size)
ZCS Power Architecture
Low Noise FM Control
Booster Versions Available for
Expanded Output Power
CE Marked
Sept. 99 1 of 4
Configuration Chart
Full-Size Modules
Mega Modules:
Single Output
VI-L
VI-M
VI-N
Dual Output
VI-P
VI-Q
Triple Output
VI-R
Junior-Size Modules
Mega Module Juniors:
Single Output
VI-LJ
Dual Output
VI-PJ
Triple Output
VI-RJ
-
-
-
-
-
-
50-200W
100-400W
300-600W
100-400W
150-600W
150-600W
4.9"
4.9"
4.9"
4.9"
4.9"
4.9"
#
of Modules
x 2.5" x 0.62"
1
x 4.9" x 0.62"
2
x 7.3" x 0.62"
3
x 4.9" x 0.62"
2
x 7.3" x 0.62"
3
x 7.3" x 0.62"
3
-
-
-
25-100W
50-200W
75-300W
2.58" x 2.5" x 0.62"
2.58" x 4.9" x 0.62"
2.58" x 7.3" x 0.62"
1
2
3
Input Voltage
Nominal
0 = 12V
1 = 24V
W= 24V
2 = 36V
3 = 48V
N = 48V
4 = 72V
T = 110V
5 = 150V
6 = 300V
7 = 150/300V
Range
Brownout Transient
10 - 20V
n/a
22
21 - 32V
18
36
18 - 36V
n/a
n/a
21 - 56V
18
60
42 - 60V
36
72
36 - 76V
n/a
n/a
55 - 100V
45
110
66 - 160V
n/a
n/a
100 - 200V
85
215
200 - 400V
170
425
100 - 375V
90
n/a
*
**
Output Voltage
Mega
Mega
Module Module Jr.
(4)
(1)
(8)
(5)
(8)
(5)
(6)
(1)
(10)
(5)
(10)
(5)
(9)
(4)
(8)
(5)
(9)
(5)
(10)
(6)
(5)
(1)
Z
Y
0
M
1
2
3
L
4
=
=
=
=
=
=
=
=
=
2V
3.3V
5V
10V
12V
15V
24V
28V
48V
s
s
(1 to 95V, consult factory)
s
s
s
s
Product Grade
E
C
I
M
=
=
=
=
Mega Module
-10°C to +85°C
-25°C to +85°C
-40°C to +85°C
-55°C to +85°C
Mega Module Jr.
-10°C to +100°C
-25°C to +100°C
-40°C to +100°C
-55°C to +100°C
Output Power/Current
Mega Module
V
OUT
5V V
OUT
< 5V
Y = 50W Y = 10A
X = 75W X = 15A
W = 100W W = 20A
V = 150W V = 30A
U = 200W U = 40A
Mega Module Jr.
V
OUT
5V V
OUT
< 5V
Z = 25W Z = 5A
Y = 50W Y = 10A
X = 75W X = 15A
W = 100W W = 20A
Product Highlights
Vicor’s Mega Module and Mega
Module Jr. Families of single, dual and
triple output DC-DC converters provide
power system designers with cost
effective, high performance, off-the-shelf
solutions to applications that might
otherwise require a custom supply.
Incorporating standard VI-200 or
VI-J00 Family converters in rugged,
chassis mount packages, Mega Module
and Mega Module Jr.’s can be ordered
with single, dual or triple outputs,
having a combined output power of up
to 600W. Totally isolated outputs
eliminate efficiency penalties and
output interaction problems.
Output Power/Current
V
OUT
5V
W = 100W
V = 150W
U = 200W
S = 300W
Q = 400W
V
OUT
< 5V
W =
20A
V =
30A
U =
40A
S =
60A
Q =
80A
Output Power/Current
V
OUT
5V
S = 300W
P = 450W
M = 600W
V
OUT
< 5V
S
= 60A
P
= 90A
M = 120A
Max. Output Per Module 5V Outputs >5V Outputs <5V Outputs
(1)
50W
50W
10A
(4)
75W
75W
15A
(5)
75W
100W
20A
(6)
100W
100W
20A
*Brownout 75% of rated load.
**Transient voltage for 1 second.
***Consult factory for availability of “T” input Mega Module Jrs.
Max. Output Per Module
(7)
(8)
(9)
(10)
5V Outputs >5V Outputs <5V Outputs
100W
150W
30A
150W
150W
30A
150W
200W
40A
200W
200W
40A
For the latest Vicor Product Information: www.vicr.com
How to use Webbrowser control in WINCE? Or can it realize the function of browsing web pages?
As the title says, I developed it in VS2005. After I pulled in the webbrowser control, the compilation was fine, but it crashed on the wince simulator. I have searched a lot of information but couldn'...
zxqwork Embedded System
How to Integrate Position Encoder Master Protocol into Sitara Processor Applications
[align=left][color=#000]In this blog post, I want to help integrate the digital position encoder master interface of your choice into a Sitara processor. [/color][/align][align=left][color=#000] First...
maylove DSP and ARM Processors
About the problem of WinCE.NET4.2 Arabic display from right to left?
1 At present, due to the addition of the corresponding codepage, the program can display Arabic correctly. 2 However, Arabic, Persian, Hebrew (and others) require the ability to display their text fro...
a3526212 Embedded System
How to Choose the Best Flash Memory for Automotive Applications
Over the past few years, the demand for NOR flash memory in automotive applications has continued to increase. NOR flash memory was initially used in areas such as infotainment and engine control. How...
qwqwqw2088 Analogue and Mixed Signal
I have a problem with the photoelectric sensor reading function of the water meter. Anyone with experience please help me!
The water meter has 4 gears (thousands, hundreds, tens, and four digits). A photoelectric tube is used to sense paper tape to realize the automatic meter reading function, replacing the previous pulse...
fefwfWF Embedded System
Please help me transplant goahead based on s3c2440
Anyone who has done goahead porting please give me some guidance. I found some information online, all of which were ported to vxworks (I followed the vxworks method to port, but it doesn't support cg...
海乐 Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1663  814  678  2647  1085  34  17  14  54  22 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号