Description
Thermal Magnetic Circuit Breaker, 3 Pole(s), 13A, 480VAC, 96VDC, Din Rail, ROHS COMPLIANT
CategoryCircuit protection    Circuit protection   
File Size507KB,6 Pages
ManufacturerEaton
Environmental Compliance
Download Datasheet Parametric View All

FAZ-B13/3 Overview

Thermal Magnetic Circuit Breaker, 3 Pole(s), 13A, 480VAC, 96VDC, Din Rail, ROHS COMPLIANT

FAZ-B13/3 Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
MakerEaton
package instructionROHS COMPLIANT
Reach Compliance Codecompliant
Actuator typeTOGGLE
Fusing characteristicsSHORT
circuit functionMANUAL ON/OFF
Circuit protection typeTHERMAL MAGNETIC
Environmental characteristicsIP20
Installation featuresDIN RAIL
Number of poles3
Maximum operating temperature75 °C
Minimum operating temperature-40 °C
Rated breaking capacity15000 A
Rated current13 A
Rated voltage (AC)480 V
Rated voltage (DC)96 V
GuidelineCCC; CE; CSA; IEC; UL; VDE
surface mountNO
Terminal shapeSCREW
UL 489 DIN rail branch circuit breakers
FAZ-NA circuit breakers
ACCESSORY TECHNICAL DATA
Shunt trip release FAZ-XAA-NA
Busbar block UL 489 (pin)
Remote release for subsequent mounting onto FAZ-NA/RT
Additional installation of standard auxiliary switch is possible
Position indicator red–green
Tested according to UL 489
Do not cut
Extension terminal 35 mm
2
Z-EK/35/UL for
copper conductors
Incoming terminal 50 mm
2
Z-EB/50/UL
For covering of not used pins, use busbar tag
shrouds ZV-BS-UL
Connection Diagram
Connection Diagram
Three-Pole Busbar
Two-Pole Busbar
Single-Pole Busbar
Shunt Trip Release FAZ-XAA-NA
Description
FaZ-Xaa-na12-110Vac
FaZ-Xaa-na110-415Vac
Busbar Block UL 489 (Pin)
Description
UL 489
iec/en 60947-2
Electrical
Can be
mounted onto
Operational
voltage range
Frequency
Mechanical
Frame size
Device height
Device width
Mounting
Degree of protection,
built-in
Terminal protection
Terminals
Terminal capacity
One and two wires
FAZ-NA / FAZ-NA-DC /
FAZ-RT
12–110 Vac
12–60 Vdc
50/60 Hz
FAZ-NA / FAZ-NA-DC /
FAZ-RT
110–415 Vac
110–230 Vdc
50/60 Hz
Electrical
Rated operational voltage
Rated frequency
Rated voltage
Overvoltage category
Rated impulse
withstand voltage U
imp
Rated current
Rated conditional short-
circuit current AC with
350A gG
Short-circuit current
Mechanical
Busbar cross section
Flame class according to
UL 94
Pollution degree
Comparative tracking index
Minimum clearance
(internal/external)
Minimum creepage
distance (internal/external)
Resistance to climatic
conditions
45 mm
45 mm
105 mm
105 mm
17.5 mm
17.5 mm
Quick fastening with two lock-in positions on EN 50022
IP40
IP40
Finger and hand touch safe according to BGV A3, ÖVE-EN 6
Open mouthed/lift
Open mouthed/lift
18–10 AWG
18–10 AWG
480/277 Vac
96 Vdc
50/60 Hz
480 Vac
80A at 40°C
10 kA
V0
690 Vac
III
9.5 kV
80A at 30°C
15 kA
16 mm
2
Cu
2
CTI 600
> 9.5/25.4 mm
> 12.7/50.8 mm
According to
DIN/EN 60068
16
eaton corporation
UL 489 and UL 1077 DIN Rail Miniature Circuit Breakers
Timing Analysis of TB5128FTG’s Decay Action
1. Chip featuresl Constant current drive controlled by PWM.l Low on-resistance (high side + low side = 0.25Ω (typ.))l Full step, half step, quarter step, 1/8 step, 1/16 step, 1/32 step, 1/64 step, 1/1...
zhijie123 Motor Drive Control(Motor Control)
Questions about switching power supply selection
There is a load with a rated working current of 300mA. The instantaneous current at startup can reach 1.3A. Is it okay to choose a switching power supply with a rated output of 1A?...
ILove羊羊 Power technology
How to convert 5V to 6V? Can someone give me a circuit diagram for reference?
How to convert 5v to 6v, please give me a circuit diagram for reference. How to convert 5v to 6v, please give me a circuit diagram for reference. How to convert 5v to 6v, please give me a circuit diag...
PCB学徒 Analogue and Mixed Signal
When loading the program, the following prompt pops up
CLA_0: Trouble Setting Breakpoint with the Action "Finish Auto Run" at 0x8591: (Error -2126 @ 0x8591) Device does not support software breakpoints. If available, use a hardware breakpoint. (Release 5....
l0700830216 Microcontroller MCU
The ten-year entrepreneurial journey of the “Major President”——Huaqing Yuanjian’s growth journey
[align=left][b]I. Preface[/b][/align] My experience 10 years ago is still envied by others: I entered the military research institute after graduating from the military academy, and was selected to wo...
bjfarsighttop Talking
There will be a meeting for teacher Li Longwen in Shenzhen on June 8th. Is anyone willing to go?
Friends in Shenzhen are in luck! The "Seventh Green Power and Power Management Technology Seminar" will be held at the Shenzhen Shengtingyuan Hotel on June 8, 2010. If you are engaged in green power o...
ledfish Power technology

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1854  2236  1788  1088  1101  38  46  36  22  23 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号