EEWORLDEEWORLDEEWORLD

Part Number

Search

PASP10-70-1I

Description
Mains Power Connector, 10A, 115/250VAC, Male, Solder Terminal, Socket
CategoryThe connector    The connector   
File Size639KB,3 Pages
ManufacturerPower Dynamics, Inc.
Websitehttp://www.powerdynamics.com/
Download Datasheet Parametric View All

PASP10-70-1I Overview

Mains Power Connector, 10A, 115/250VAC, Male, Solder Terminal, Socket

PASP10-70-1I Parametric

Parameter NameAttribute value
MakerPower Dynamics, Inc.
Reach Compliance Codecompliant
Other featuresSTANDARDS: IEC 60320; VDE
Body/casing typeSOCKET
Connector typeMAINS POWER CONNECTOR
Contact point genderMALE
Coupling typeSNAP
DIN complianceNO
IEC complianceYES
MIL complianceNO
Power Connector Ratings10A, 115/250VAC
Manufacturer's serial numberPASP
Installation typeBOARD AND PANEL
OptionsGENERAL PURPOSE
Termination typeSOLDER
Total number of contacts3
POWER LINE FILTER
PASP Series
RIGHT ANGLE, PC BOARD MOUNT FILTER WITH IEC 60320
AC INLET SOCKET.
MECHANICAL DIMENSIONS
(Unit: mm)
50.1
40.0
20.5
18.6
21.3
6.5
G
22.5
28.2
24.4
20.2
2x
3.3
30.3
36.3
39.8
41.3
FEATURES
The PASP series are offered with right angle PCB mount
terminals. This filter with IEC connector provides effective
equipment protection in line-to-ground noise up to 15 Amp,
250VAC. These compactly designed filters with low leakage
current are well suited for applications that require strict
emission standards. These filters are also available for
Medical application and offer extremely low Leakage
current to comply with various industry standards.
A ground choke can be added to enhance the grounding
ability of the circuit. Bleeder resistor can also be added to
prevent excessive voltages from developing across the filter
capacitors when there is no load.
40.0
30.5
+0.2
2x
21.8
+0.2
3.5
21.3
18.6
4x
2
R5 TYP.
RECOMMEDED
PANEL CUTOUT
20.5
RECOMMEDED
PCB LAYOUT
APPLICATIONS
Computer & networking equipment, Measuring & control
equipment, Data processing equipment, laboratory instruments,
Switching power supplies, other electronic equipment.
TECHNICAL DATA
Rated Voltage: 115/250VAC
Rated Current: 1A, 2A, 3A, 6A, 10A, 15A
Power Line Frequency: 50/60Hz
Max. Leakage Current each
Line to Ground:
@ 115VAC 60Hz: 0.25mA
@ 250VAC 50Hz: 0.45mA
@ 115VAC 60Hz: 2
µ
A*
@ 250VAC 50Hz: 5
µ
A*
Hipot Rating (one minute)
Line to Ground: 2250VDC
Line to Line: 1450VDC
Temperature Range: -25C to +85C
* Medical application
Specifications subject to change without notice. Dimensions (mm). See Appendix A for
recommended power cord. See PDI full line catalog for detailed specifications on power cords.
145 Algonquin Parkway, Whippany, NJ 07981 • 973-560-0019 • FAX: 973-560-0076
e-mail: filtersales@powerdynamics.com •
www.powerdynamics.com
19

Recommended Resources

LM3S8962UART controls MODEM communication 3 UART drives MODEM function
LM3S8962UART drives MODEM bottom driver function: LM23S8962 development board and MODEM are connected through serial port, but because the development board does not provide UART to RS-232C interface ...
beyondvv Microcontroller MCU
The Japanese 110v CD player is connected to 220v. Please help me.
A friend brought a CD player to me. A roadside appliance repairman disassembled it and said it couldn't be fixed. I disassembled it and it seemed that the transformer was burned. I bought a 220v to 11...
t29125272 Power technology
Network audio and video communication based on wince (simple and easy to understand version)
[i]This article comes from [url=http://blog.csdn.net/hellogv/]http://blog.csdn.net/hellogv/[/url] [/i][u][size=3] [/size][/u][font=宋体, MS Song][size=3][/size][/font][font=宋体][size=13pt] As the end of ...
绿茶 Embedded System
About the function of stabs debugging section in skyeye program
.stab_info 0 : { *(.debug_info) } .debug_line 0 : { *(.debug_line) } .debug_pubnames 0 : { *(.debug_pubnames) } .debug_aranges 0 : { *(.debug_aranges) } can start skyeye, otherwise it will show error ...
asqw Embedded System
se8690 Technical Data
SE8690D Low Power ÷10/11 Preset Divider...
lorant Industrial Control Electronics
FPGA QQ group: 69611574 Looking forward to your joining!
FPGA QQ group: 69611574 Looking forward to your joining!...
fpga126 FPGA/CPLD

Popular Articles

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1417  2695  2557  2736  808  29  55  52  56  17 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号