Part Number

Search

802-008-06ZM5-3SB

Description
Circular Connector, 3 Contact(s), Stainless Steel, Female, Crimp Terminal, Plug,
CategoryThe connector    The connector   
File Size108KB,2 Pages
ManufacturerGlenair
Websitehttp://www.glenair.com/
Download Datasheet Parametric View All

802-008-06ZM5-3SB Overview

Circular Connector, 3 Contact(s), Stainless Steel, Female, Crimp Terminal, Plug,

802-008-06ZM5-3SB Parametric

Parameter NameAttribute value
MakerGlenair
Reach Compliance Codecompliant
Back shell typeSOLID
Body/casing typePLUG
Connector typeCIRCULAR CONNECTOR
Contact to complete cooperationGOLD
Contact completed and terminatedGOLD
Contact point genderFEMALE
Coupling typeTHREADED
DIN complianceNO
empty shellNO
Environmental characteristicsCORROSION RESISTANT
Filter functionNO
IEC complianceNO
JESD-609 codee4
MIL complianceNO
Plug informationMULTIPLE MATING PARTS AVAILABLE
Mixed contactsNO
Installation typeCABLE
OptionsGENERAL PURPOSE
Shell surfaceNICKEL PLATED
Shell materialSTAINLESS STEEL
Housing size5
Termination typeCRIMP
Total number of contacts3
Series 802 “Aqua Mouse”
3500 PSI Rated
Series 802 Plug Connectors
A
Stainless Steel Shell
and
Nickel-
Aluminum-Bronze Coupling Nut
withstand corrosion in the most
hostile environments. Rated for 3500
PSI when mated, these connectors
are suitable for geophysical and
underwater applications.
Gold-Plated Contacts
are supplied
loose for crimping to wire. High density
size 23 contact arrangements accept
#22 – #30 AWG wire, or choose #12
or #16 contacts for higher current.
Two Shell Styles:
Integral platform
for direct shield attachment using
BAND-IT® termination system, or
accessory thread for attaching a strain
relief.
Series 802 Plugs
HOW TO ORDER SERIES 802 PLUGS
Sample Part Number
802-009
Series
-06
Shell
Style
-06
Plug
ZM
Shell Material / Finish
Z1
9-19
Shell Size- Insert
Arrangement
S
Contact Type
A
Shell Key
Position
A
Normal
802-008
Plug with Banding
Platform
5-3
Stainless Steel / Passivated
6-1
6-4
ZM
6-7
Stainless Steel / Electroless
7-1
Nickel Plated
7-10
8-13
9-4
9-19
10-26
12-2
12-37
14-55
15-85
Standard #23 contacts
3 #23 Contacts
accept #22 through
1 #16 Contact
#28 AWG wire. Use the
4 #23 Contacts
following contact codes to
7 #23 Contacts
specify these contacts:
1 #12 Contact
P
10 #23 Contacts
Pin
13 #23 Contacts
4 #16 Contacts
S
19 #23 Contacts
Socket
26 #23 Contacts
Special contacts for
2 #12 Contacts
#26 to #30 AWG are
37 #23 Contacts
also available. Use the
55 #23 Contacts
following contact codes to
85 #23 Contacts
specify these contacts:
B
Pos. B
C
Pos. C
D
Pos. D
802-009
Plug with Accessory
Thread
#23 contacts are packaged
with connectors. #16 and #12
contacts must be ordered
separately.
G
Pin
H
Socket
© 2007 Glenair, Inc.
CAGE Code 06324
Printed in U.S.A.
GLENAIR, INC. • 1211 AIR WAY • GLENDALE, CA 91201-2497 • 818-247-6000 • FAX 818-500-9912
www.glenair.com
E-3
Rev. 05-APR-2007
E-Mail: sales@glenair.com
Series 800
B
C
D
E
F
G
H
J
K
L
M
Encoder chip HD7279A test program
[url=http://www.ele169.com/Soft/ShowSoft.asp?SoftID=91]Encoding chip HD7279A test program[/url]...
黑衣人 MCU
TI DSP TMS320C66x study notes TI official BMP reading program (I)
[p=26, null, left][color=#333333][font=Arial] I have always wanted to write down my study notes on DSP, but due to time and laziness, I have hesitated for a long time and have not been able to pick up...
Mars_WH DSP and ARM Processors
Where are variables such as CE_MODULES_PPP defined in the config.reg file?
Where are variables like CE_MODULES_PPP defined in the config.reg file? Where do I configure these variables so that they can be compiled into the kernel?...
rong81117 Embedded System
Precious home appliance anti-theft alarm
[i=s]This post was last edited by jameswangsynnex on 2015-3-3 19:56[/i]This valuable home appliance anti-theft alarm has the characteristics of small size and loud sound. It is suitable for use in hom...
探路者 Mobile and portable
How to design a triode amplifier circuit
Design Steps 1) Analyze and design requirementsThe voltage gain can be used to calculate the voltage amplification factor; the maximum output voltage can be used to set the power supply voltageThe out...
fish001 Analogue and Mixed Signal
Is it necessary to install Vs2k5 SP1 and Platform Builder Service Pack 1 when using VS2005+PB FOR CE6.0?
Is it necessary to install Vs2k5 SP1 and Platform Builder Service Pack 1 when using VS2005+PB FOR CE6.0? ? Without installing these two patches, why can't the NB.bin I generated be loaded by the simul...
yuping Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1503  876  11  1596  2421  31  18  1  33  49 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号