EEWORLDEEWORLDEEWORLD

Part Number

Search

CFE400M12-5H-N1-UML-NT

Description
300W Convection / 400W Fan Cooled Medical Power Supplies
File Size379KB,2 Pages
ManufacturerTDK Corporation
Websitehttp://www.tdk.com
Download Datasheet View All

CFE400M12-5H-N1-UML-NT Overview

300W Convection / 400W Fan Cooled Medical Power Supplies

CFE400M Series
300W Convection / 400W Fan Cooled Medical Power Supplies
Features
u
Medical & ITE Safety Certifications (BF Rated)
u
94% Efficient
u
0.5W Standby Power
u
Meets ERP/Eco-Design (2009/125/EC)
u
Meets Climate Savers Gold Level
u
450W Peak Loading (10s)
u
High Power Density (7” x 4” x 1.6”)
u
Suitable for 1U applications
u
Five Year Warranty
Key Market Segments & Applications
Specifications
Model
Input Voltage range
Input Frequency
Inrush Current
Power Factor Harmonics
Voltage Setting Accuracy
Regulation
Ripple & Noise
Efficiency (230VAC, 80% load)
Overcurrent Protection
Overvoltage Protection
Overtemperature Protection
Hold Up Time (Typ)
Leakage Current (max)
Fan Supply
Standby Voltage
Remote Sense
Signals & Features
Operating Temperature
(1)
VAC
Hz
A
-
%
%
mV
%
-
V
-
ms
mA
-
-
-
-
°C
CFE400M
85 - 264VAC
47 - 63Hz, 440Hz with reduced PFC
<20A at 25°C and 230VAC input, Cold Start
EN61000-3-2 Compliant. Class A (Class C >100W output power)
±1% at 50% Load
Line: 0.25%; Load: 1%; Thermal Coefficient: 0.02%/°C
1% peak-peak
94% typical (48V & 24V), 91% (12V), 0.5W power draw in standby mode
Automatic recovery upon overload removal
Cycle AC line to reset
Yes
15ms at full load
140mA 120VAC 60Hz, 280mA 240VAC 60hz, <300mA 240VAC 63Hz (Type Test results)
12V 0.25A (Not available if the top fan option is selected)
5V 80mA or 5V 2A (chosen at time of ordering)
None
Remote on/off - Inhibit or Enable operation (chosen at time of ordering)
Power Good - High indicates DC output & AC input is good. ORing FET - (Option)
Convection cooled: 0 to +60°C. Derate linearly to 50% load from 40°C to 60°C
Forced air cooled: 0 to +70°C. Derate linearly to 50% load from 50°C to 70°C
-40 to +70°C
5 - 95%RH
Convection, internal fan or external 1.5m/s forced air , approx. 12 CFM (see oper. temp.)
Input to Ground 1500VAC, Input to Output 4kVAC (Reinforced), Output to Ground 1500VAC
2G, 10-500Hz in all 3 planes. MIL-STD-810E, Method 514.4, Pro I, Cat 1, 9
30G per IEC68-2-27, MIL-STD-810E/F, Method 516.5, Pro I, IV, VI
IEC/UL/EN/CSA22.2 60601-1, IEC/UL/EN 61010-1, IEC/UL/EN/CSA22.2 No 60950-1, CE for LVD
EN61000-4-2, -3, -4, -5, -6, -8, -11, -12, -14
EN55011, EN55022 Class B (per CISPR.11/22), EN61000-3-3
EN55011, EN55022 Class B (per CISPR.11/22)
U Channel: 0.71kg, Top fan: 0.86kg
U channel: 7 x 3.94 x 1.6, With cover: 7 x 3.94 x 2, Top Fan: 7 x 3.94 x 2.8
Five Years
Storage Temperature
°C
Humidity (non condensing)
%RH
Cooling
-
Isolation
-
Vibration (non operating)
-
Shock
-
Safety Agency Certifications (2)
-
Immunity
-
Conducted Emissions and Flicker
-
Radiated Emissions
-
Weight (open frame)
kg
Size
in
Warranty
yrs
(1) -20°C cold start
(2) Designed to meet IEC/EN/UL/CSA 61010-1 Edition 2
1-800-526-2324 • www.us.tdk-lambda.com/lp/
19
Disclaimer: us.tdk-lambda.com/lp/legal.htm
Wince battery percentage display
I use wince4.2. After adding the battery driver, I compiled and generated the nk file for testing. I found that the battery property interface of the control panel lacks the power percentage display, ...
梦幻泡影 Embedded System
When initializing a segment, a HardFaultException occurs during INITTAB processing
HardFault occurs at startupTracing with the simulator, it occurs when the segment is initialized, probably at the INITTAB processing location.I checked the data of the INITTAB address:0d 0a 00 00 00 0...
dujin stm32/stm8
Driver development emergency
Tel: 021-63503099*807 E-mail: annie.zhou@echocc.comJob title: Snr Software Engineer –Project LeaderResponsibilities: To be part of the software team, be responsible for some of the activities below: (...
zsda2007 Embedded System
I want to make a host computer for a microcontroller, please give me some guidance.
I have almost no experience. I need to make a computer interface to receive data sent from the microcontroller to the computer through the USB interface and save it in a database. And I can control th...
挨紧 TI Technology Forum
MCS-51 Microcontroller Practical Subroutine Library (1996 Edition)
At present, several versions of subroutine libraries have been published, each with its own characteristics. In 1988, the author also compiled two subroutine libraries (fixed-point subroutine library ...
wuguo Industrial Control Electronics
mips (smp8634) configure GPIO interrupt (urgent)
1. Is it possible to configure only GPIO8, 9, 10, 11 as interrupts? 2. I use LOG2_CPU_PCI_INTC (1). Configure it as rising edge trigger gbus_writel(REG_BASE_cpu_block+CPU_edge_config_rise_set,1 Have y...
zxzj888 Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 237  2328  15  1574  612  5  47  1  32  13 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号