EEWORLDEEWORLDEEWORLD

Part Number

Search

SR46S00010029

Description
Rocker Switch, DPDT, Latched, 0.02A, 20VDC, Solder Terminal, Paddle Type Actuator, Panel Mount
CategoryMechanical and electronic products    switch   
File Size289KB,10 Pages
ManufacturerAPEM
Environmental Compliance  
Download Datasheet Parametric View All

SR46S00010029 Overview

Rocker Switch, DPDT, Latched, 0.02A, 20VDC, Solder Terminal, Paddle Type Actuator, Panel Mount

SR46S00010029 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerAPEM
Reach Compliance Codecompliant
ECCN codeEAR99
Actuator typePADDLE TYPE
body width11.35 mm
body height10.8 mm
Body length or diameter12.7 mm
Contact (AC) maximum rated R load.02A@20VAC
Maximum contact current (AC)0.02 A
Maximum contact current (DC)0.02 A
Contact (DC) maximum rated R load.02A@20VDC
Maximum contact voltage (AC)20 V
Maximum contact voltage (DC)20 V
Electrical life100000 Cycle(s)
Manufacturer's serial numberSR
Installation featuresPANEL MOUNT
Maximum operating temperature85 °C
Minimum operating temperature-20 °C
method of packingBULK
sealEPOXY TERMINAL SEALED
surface mountNO
Switch actionLATCHED
switch functionDPDT
Switch typeROCKER SWITCH
Termination typeSOLDER
S and SR series
Washable rocker and paddle switches
Distinctive features and specifications
Sealed
• Secure assembly of the two case parts
• Internally sealed bushing
• Epoxy sealed terminals
Process compatible (S series)
• Wave solderable
• Washable
Optional ESD protection
ELECTRICAL SPECIFICATIONS
MATERIALS
D
• Max. current/voltage rating with resistive load :
- silver contacts (A or 1) : 2A 250VAC - 5A 125VAC - 4A 30VDC
- brass, gold plated contacts (CD or 0) : 0,4VA 20VAC or DC
- silver, gold plated contacts (AD or 2) : 2A 250VAC - 5A 125VAC - 4A 30VDC
(300mA 30VDC for gold plating)
• Initial contact resistance : 10 mΩ max.
• Insulation resistance : 1.000 MΩ min.
• Dielectric strength : 1.000 Vrms 50 Hz min.
• Electrical life with nominal load :
Contacts
A or 1
CD or 0
AD or 2
Number of cycles
2 positions
40.000
100.000
40.000
3 positions
40.000
50.000
40.000
• Case and cover : UL94-V0,
polyamide, glass filled or PES
• Actuator : polyamide
• Contacts
CD
or
0
: brass, gold plated
A
or
1
: silver
AD
or
2
: silver, gold plated
• Terminal seal : epoxy
GENERAL SPECIFICATIONS
AGENCY APPROVALS
• Mechanical strength :
Terminals are strengthened by a bracket or a ground plate ensuring the
rigidity of the switch on the board. Actuator strength is 10N max.
• Operating temperature : -20°C to +85°C
• Storage temperature : -40°C to +85°C
• Moisture :
The insulating materials employed and the complete seal permit the switches
to withstand a 56 days moisture test (IEC 68-2-3).
• Soldering - thermal shock (S series only) :
The switches are especially designed for flow soldering at 260°C during
5 seconds owing to high temperature polymer parts.
• Iron soldering (SR series) : 300°C 5 sec. max.
• Solderability : The switches are tested at 235°C according to IEC 68-2-20
after accelerated aging.
Availability
: consult factory for
details of approved models.
Marking
: to order switches
marked UL, complete appropriate
box of ordering format.
D-10
www.apem.com
APEM
Electronic Design Competition Analog Electronics - Analog Integrated Circuit Design
You can take a look at this old but still very valuable reference:)...
brian-law Electronics Design Contest
Motor Synchronous Control System and Communication Based on DSP and CAN
[size=4]The traditional multi-motor control system is suitable for occasions with low requirements, relatively simple, and relatively concentrated motor distribution. However, for occasions with high ...
fish001 DSP and ARM Processors
[I "painted" the periphery of the C2000 LaunchPad] -----Electronic Load_Summary
I have actually started working on this electronic load a long time ago. However, I have been doing it here and there without taking it seriously. Even now, I have not finished it completely. I plan t...
dontium Microcontroller MCU
Design of three-phase UPS for power system
In the power system, in order to ensure that important equipment with high power supply reliability requirements can work normally, power plants and substations should be installed with UPS. With the ...
zbz0529 Power technology
BT8896A Specification (Zhongke Bluexun)
Keep sharing, and like it if you like it!...
Fred_1977 Download Centre
What is the amplification factor of this op amp?
I calculated 1.5, I don't know if it is correct, please help me...
shijizai Analog electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 291  676  2319  1614  1423  6  14  47  33  29 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号