EEWORLDEEWORLDEEWORLD

Part Number

Search

56.32.9.012.2030

Description
Electromechanical Relay, DPDT, 13.2VDC (Coil), 1000mW (Coil), Random, AC/DC Output
CategoryMechanical and electronic products    relay   
File Size2MB,10 Pages
ManufacturerFINDER
Download Datasheet Parametric View All

56.32.9.012.2030 Overview

Electromechanical Relay, DPDT, 13.2VDC (Coil), 1000mW (Coil), Random, AC/DC Output

56.32.9.012.2030 Parametric

Parameter NameAttribute value
MakerFINDER
Reach Compliance Codecompliant
body width20.7 mm
body height37.2 mm
Body length or diameter27.7 mm
Coil operating voltage (DC)9.6 V
Coil power1000 mW
Coil resistance140 Ω
Maximum coil voltage (DC)13.2 V
Nominal coil voltage12 V
Coil/Input Power TypeDC
Contact (AC) maximum rated R load20A@400VAC
Maximum contact current (AC)20 A
Maximum contact voltage (AC)400 V
Contact/Output Power TypeAC/DC
Dielectric strength between coil and contacts4000 Vrms
Dielectric strength between breaking contacts1000 Vrms
Electrical life100000 Cycle(s)
End contact materialSilver Cadmium Oxide
Input switching control typeRandom
Number of terminals8
operating hours8 ms
physical size27.7mm x 20.7mm x 37.2mm
GuidelineCSA; IMQ; PCT; UL; VDE
Relay functionDPDT
release time3 ms
Terminal length0.007 inch
Termination typeQUICK CONNECT
56
56 Series - Miniature power relays 12 A
Features
Plug-in - 12 A Power relay, 2 & 4 pole
Flange mount option -
(Faston 187, 4.8x0.5 mm termination)
AC coils & DC coils
Lockable test button and mechanical flag indicator
Cadmium Free contacts (standard version)
Contact material options
96 series sockets
Coil EMC suppression
Accessories
European Patent
SERIES
56.32/56.34
56.32-0300
Plug-in / PCB Relays
1
2 or 4 pole changeover contact
Plug-in/Faston 187
2 pole normally open contact
(≥1.5 mm gap)
Plug-in/Faston 187
56.32
56.32-0300
56.34
* For 4 CO (4PDT) only.
F
OR
UL
RATINGS SEE
:
“General technical information” page
V
Contact specification
Contact configuration
Rated current/Maximum peak current
Rated load AC1
Rated load AC15 (230 V AC)
Single phase motor rating (230 V AC)
Breaking capacity DC1: 30/110/220 V
Minimum switching load
Standard contact material
Coil specification
Nominal voltage (U
N
)
Rated power AC/DC
Operating range
Holding voltage
Must drop-out voltage
Technical data
Mechanical life AC/DC
Electrical life at rated load AC1
Operate/release time
XI-2013, www.findernet.com
56.32
56.34
56.32-0300
2 CO (DPDT)
A
VA
VA
kW
A
12/20
250/400
3,000
700
0.55
4 CO (4PDT)
2NO (DPST-NO) -
≥1.5mm
gap
12/20
250/400
3,000
700
0.55
12/1/0.5
500 (10/5)
AgNi
Rated voltage/Maximum switching voltage V AC
12/0.5/0.25
500 (10/5)
AgNi
mW (V/mA)
V AC (50/60 Hz)
V DC
VA (50 Hz)/W
AC
DC
AC/DC
AC/DC
cycles
cycles
ms
V AC
°C
8/3
4
1.5/1
6 - 12 - 24 - 48 - 60 - 110 - 120 - 230 - 240 - 400*
6 - 12 - 24 - 48 - 60 - 110 - 125 - 220
2/1.3
(0.8…1.1)U
N
(0.8…1.1)U
N
(0.85…1.1)U
N
0.8 U
N
/0.6 U
N
0.2 U
N
/0.1 U
N
20 · 10
6
/50 · 10
6
100 · 10
3
10/4
5
1,000
–40…+70
RT I
1.5/—
(0.85…1.1)U
N
0.85 U
N
/—
0.2 U
N
/—
20 · 10
6
/—
100 · 10
3
8/4
4
2,000
–40…+70
RT I
Insulation between coil and contacts (1.2/50 µs) kV
Dielectric strength between open contacts
Ambient temperature range
Environmental protection
Approvals
(according to type)
A small bug in mpy on ESP32/ESP8266
I found a small bug on ESP32/ESP8266. If you import a library, and then type __class__. after the library name in the repl and press the tab key (autocomplete function), it will cause the system to re...
dcexpert MicroPython Open Source section
Complete C language program examples
This is a classic 220 C language example. I wonder if there is one here in the forum...
yubinwu Download Centre
How to make your resume a top-notch one? Avoid these 10 common mistakes:
How to make your resume a first-rate one? Avoid these 10 common mistakes: 1. Focusing too much on job responsibilities The most common mistake in resumes is to turn them into a boring list of responsi...
songbo Talking
【XMC4800 Relax EtherCAT Kit Review】+ Getting Started with DAVE, PWM Module Application
[align=left][color=rgb(0, 0, 0)][font=Calibri, sans-serif][size=10.5pt]Today I will continue to share how to use the PWM module. Today I will use the PWM module to make a breathing light application a...
flyword Industrial Control Electronics
A short message program for microbit written by a 13-year-old kid from abroad
[i=s]This post was last edited by dcexpert on 2017-6-16 11:06[/i] [size=14px]This is a program written by William, a 13-year-old kid from abroad, which can send short messages between micro:bits wirel...
dcexpert MicroPython Open Source section
Switching Power Supply Design Detailed Explanation
Switching Power Supply Design Detailed ExplanationDetailed explanation of switching power supply design, from formulas to practical applications, with attached design drawings, absolutely good informa...
Fireflye Analogue and Mixed Signal

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1530  844  1334  1179  1542  31  17  27  24  32 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号