Part Number

Search

56.34.8.110.0300

Description
Electromechanical Relay, 4PDT, AC/DC Output
CategoryMechanical and electronic products    relay   
File Size2MB,10 Pages
ManufacturerFINDER
Download Datasheet Parametric View All

56.34.8.110.0300 Overview

Electromechanical Relay, 4PDT, AC/DC Output

56.34.8.110.0300 Parametric

Parameter NameAttribute value
MakerFINDER
Reach Compliance Codecompliant
body width27.7 mm
body height37.1 mm
Body length or diameter40.8 mm
Coil operating voltage (AC)88 V
Coil resistance1900 Ω
Maximum coil voltage (AC)121 V
Nominal coil voltage110 V
Coil/Input Power TypeAC
Contact (AC) maximum rated R load20A@400VAC
Maximum contact current (AC)20 A
Maximum contact voltage (AC)400 V
Contact/Output Power TypeAC/DC
Dielectric strength between coil and contacts5000 Vrms
Dielectric strength between breaking contacts2000 Vrms
Electrical life100000 Cycle(s)
End contact materialSilver Nickel
Number of terminals14
operating hours10 ms
physical size40.8mm x 27.7mm x 37.1mm
GuidelineCSA; IMQ; PCT; UL; VDE
Relay function4PDT
release time4 ms
Terminal length0.007 inch
Termination typeQUICK CONNECT
56
56 Series - Miniature power relays 12 A
Features
Plug-in - 12 A Power relay, 2 & 4 pole
Flange mount option -
(Faston 187, 4.8x0.5 mm termination)
AC coils & DC coils
Lockable test button and mechanical flag indicator
Cadmium Free contacts (standard version)
Contact material options
96 series sockets
Coil EMC suppression
Accessories
European Patent
SERIES
56.32/56.34
56.32-0300
Plug-in / PCB Relays
1
2 or 4 pole changeover contact
Plug-in/Faston 187
2 pole normally open contact
(≥1.5 mm gap)
Plug-in/Faston 187
56.32
56.32-0300
56.34
* For 4 CO (4PDT) only.
F
OR
UL
RATINGS SEE
:
“General technical information” page
V
Contact specification
Contact configuration
Rated current/Maximum peak current
Rated load AC1
Rated load AC15 (230 V AC)
Single phase motor rating (230 V AC)
Breaking capacity DC1: 30/110/220 V
Minimum switching load
Standard contact material
Coil specification
Nominal voltage (U
N
)
Rated power AC/DC
Operating range
Holding voltage
Must drop-out voltage
Technical data
Mechanical life AC/DC
Electrical life at rated load AC1
Operate/release time
XI-2013, www.findernet.com
56.32
56.34
56.32-0300
2 CO (DPDT)
A
VA
VA
kW
A
12/20
250/400
3,000
700
0.55
4 CO (4PDT)
2NO (DPST-NO) -
≥1.5mm
gap
12/20
250/400
3,000
700
0.55
12/1/0.5
500 (10/5)
AgNi
Rated voltage/Maximum switching voltage V AC
12/0.5/0.25
500 (10/5)
AgNi
mW (V/mA)
V AC (50/60 Hz)
V DC
VA (50 Hz)/W
AC
DC
AC/DC
AC/DC
cycles
cycles
ms
V AC
°C
8/3
4
1.5/1
6 - 12 - 24 - 48 - 60 - 110 - 120 - 230 - 240 - 400*
6 - 12 - 24 - 48 - 60 - 110 - 125 - 220
2/1.3
(0.8…1.1)U
N
(0.8…1.1)U
N
(0.85…1.1)U
N
0.8 U
N
/0.6 U
N
0.2 U
N
/0.1 U
N
20 · 10
6
/50 · 10
6
100 · 10
3
10/4
5
1,000
–40…+70
RT I
1.5/—
(0.85…1.1)U
N
0.85 U
N
/—
0.2 U
N
/—
20 · 10
6
/—
100 · 10
3
8/4
4
2,000
–40…+70
RT I
Insulation between coil and contacts (1.2/50 µs) kV
Dielectric strength between open contacts
Ambient temperature range
Environmental protection
Approvals
(according to type)
What is your understanding of Article 82 of the Labor Contract Law of the People’s Republic of China?
[i=s]This post was last edited by yhyworld on 2020-4-19 22:00[/i]The following figure shows Article 82 of the Labor Contract Law of the People's Republic of China.On March 25 this year, the company fo...
yhyworld Talking about work
Activity: Share your first post on EEWORLD
:) Review your first steps in EEWORLDOh my god, I actually quoted a cat. May the cat be happy....
soso Talking
Aeroflex 5800 Series Equipment Meets Evolving Automated Test Needs
If you are an engineer and are doing mixed signal testing, device programming, functional testing, in-system programming, or simple protocol communications, the 5800 Series [url=http://www.eetchina.co...
clj2004000 PCB Design
【KW41Z】Environment construction gcc+jlink
[i=s]This post was last edited by lzwml on 2017-7-1 14:38[/i] [b][color=#5E7384]This content was originally created by [size=3]lzwml[/size], a netizen on the EEWORLD forum. If you want to reprint or u...
lzwml NXP MCU
【MXCHIP Open1081】Why can't IAR download the program?
When using IA77.0 and ST-LINK to program Open1081, the program cannot be downloaded to the chip. The prompt is: Fatal error: There were warnings during download of FLASH loader, see Log Window Session...
dontium RF/Wirelessly
Today I can calm down and study LPC
Finally, the defense is over. Today, I can calm down and study LPC. Haha, the administrator even called me. I feel so sorry. I must study it carefully and at least fulfill my original promise! Haha! N...
dxhuo Talking

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 928  2583  1058  2056  2641  19  52  22  42  54 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号