5226303 | P3® 625 JCASS SM MT
75 Ohm P3® Trunk and Distribution Cable, black PE jacket, flooded for
underground
Product Classification
Brand
Product Type
P3®
Coaxial hardline cable
Construction Materials
Corrosion Protection
Jacket Material
Center Conductor Material
Construction Type
Dielectric Material
Outer Conductor Material
Migraheal®
PE
Copper-clad aluminum
Swaged
Foam PE
Aluminum
Dimensions
Diameter Over Center Conductor, nominal
3.480 mm | 0.137 in
Diameter Over Dielectric, nominal
Diameter Over Inner Jacket, nominal
Diameter Over Jacket, nominal
Inner Jacket Thickness, nominal
Jacket Thickness, nominal
Outer Conductor Thickness, nominal
Cable Length
Shipping Weight
14.351 mm | 0.565 in
17.653 mm | 0.695 in
21.590 mm | 0.850 in
0.762 mm | 0.030 in
0.7620 mm | 0.0300 in
0.7620 mm | 0.0300 in
732 m | 2400 ft
187.00 lb/kft
Diameter Over Outer Conductor, nominal
15.875 mm | 0.625 in
Electrical Specifications
dc Resistance, Inner Conductor, nominal
dc Resistance, Outer Conductor, nominal
dc Resistance, Loop, nominal
dc Resistance Note
Capacitance
Capacitance Tolerance
Characteristic Impedance
Characteristic Impedance Tolerance
Jacket Spark Test Voltage
Nominal Velocity of Propagation (NVP)
0.84 ohms/kft
0.26 ohms/kft
1.10 ohms/kft
Nominal values based on a standard condition of 20 °C (68 °F)
50.2 pF/m | 15.3 pF/ft
±1.0 pF/ft
75 ohm
±2 ohm
5000 Vac
87 %
page 1 of 3
July 1, 2019
©2019 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks,
respectively, of CommScope.All specifications are subject to change without notice. See www.commscope.com for the
most current information. Revised: May 3, 2019
5226303 | P3® 625 JCASS SM MT
Operating Frequency Band
Structural Return Loss
5–3000 MHz
26 dB @ 1002–1218 MHz | 30 dB @ 5–1002 MHz
Environmental Specifications
Environmental Space
Buried
General Specifications
Cable Type
Jacket Color
Packaging Type
Warranty
625 series
Black
Reel
One year
Mechanical Specifications
Minimum Bend Radius, bonded
Pulling Tension, maximum
114.30 mm | 4.50 in
215 kg | 475 lb
Electrical Performance
Frequency
5 MHz
55 MHz
83 MHz
85 MHz
204 MHz
211 MHz
250 MHz
300 MHz
350 MHz
400 MHz
450 MHz
500 MHz
550 MHz
600 MHz
750 MHz
865 MHz
1000 MHz
1002 MHz
1218 MHz
1300 MHz
1400 MHz
1500 MHz
1600 MHz
1700 MHz
1794 MHz
1800 MHz
2000 MHz
Attenuation (dB/100 m)
0.43
1.48
1.84
1.84
2.92
3.02
3.28
3.54
3.87
4.17
4.43
4.69
4.92
5.18
5.84
6.33
6.79
6.80
7.63
7.94
8.29
8.62
8.95
9.27
9.56
9.58
10.19
Attenuation (dB/100 ft)
0.13
0.45
0.56
0.56
0.89
0.92
1.00
1.08
1.18
1.27
1.35
1.43
1.50
1.58
1.78
1.93
2.07
2.07
2.33
2.42
2.53
2.63
2.73
2.83
2.92
2.93
3.11
page 2 of 3
July 1, 2019
©2019 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks,
respectively, of CommScope.All specifications are subject to change without notice. See www.commscope.com for the
most current information. Revised: May 3, 2019
5226303 | P3® 625 JCASS SM MT
2200
2400
2600
2800
3000
MHz
MHz
MHz
MHz
MHz
10.78
11.35
11.90
12.44
12.96
3.28
3.46
3.63
3.79
3.95
* Attenuation listed represents maximum values at standard condition of 20 °C (68 °F)
Regulatory Compliance/Certifications
Agency
RoHS 2011/65/EU
ISO 9001:2015
Classification
Compliant
Designed, manufactured and/or distributed under this quality management system
page 3 of 3
July 1, 2019
©2019 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks,
respectively, of CommScope.All specifications are subject to change without notice. See www.commscope.com for the