EEWORLDEEWORLDEEWORLD

Part Number

Search

LCS051T07SB22DW

Description
SNAP ACTING/LIMIT SWITCH, SPST, MOMENTARY, 5.8mm, PANEL MOUNT, ROHS COMPLIANT
CategoryMechanical and electronic products    switch   
File Size229KB,4 Pages
ManufacturerC&K
Environmental Compliance  
Download Datasheet Parametric View All

LCS051T07SB22DW Overview

SNAP ACTING/LIMIT SWITCH, SPST, MOMENTARY, 5.8mm, PANEL MOUNT, ROHS COMPLIANT

LCS051T07SB22DW Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerC&K
package instructionROHS COMPLIANT
Reach Compliance Codecompliant
ECCN codeEAR99
Actuator stroke5.8 mm
Actuator typeSHORT LEVER
body width6.4 mm
body height9.8 mm
Body length or diameter19.8 mm
Contact (AC) maximum rated R load6A@250VAC
Maximum contact current (AC)6 A
Maximum contact voltage (AC)250 V
Electrical life10000 Cycle(s)
Manufacturer's serial numberLCS
Installation featuresPANEL MOUNT
Maximum operating force1.47 N
Maximum operating temperature125 °C
Minimum operating temperature-40 °C
Maximum pre-travel4.8 mm
sealIP67
surface mountNO
Switch actionMOMENTARY
switch functionSPST
Switch typeSNAP ACTING/LIMIT SWITCH
Termination typeSOLDER
LCS Series
Subminiature Sealed Snap-acting Switches
Features/Benefits
Compact design
Long life and high electrical capacity
Quick connect, solder terminals,
PC terminals, wire leads
Wide variety of actuator styles
RoHS compatible, RoHS compliant
IP67
Specifications
CONTACT RATING: 6 AMP, 125/250 V AC
and
5 AMP, 125/250 V AC
0.1 AMP, 125/250 V AC
ELECTRICAL LIFE: 10,000 cycles
INSULATION RESISTANCE: 100 M ohm min.
DIELECTRIC STRENGTH: 1,000 VAC
OPERATING TEMPERATURE: –40ºC to +125ºC without wire
–40ºC to +85ºC with wires
OPERATING FORCE: (see ACTUATOR’S option sections).
MOUNTING: 2-56 screws, torque 2.3 in/lbs max.
NOTE:
Specifications and materials listed above are for switches with standard options.
For information on specific and custom switches, consult Customer Service center.
14
Typical Applications
Motorized equipment
Sump pump
Thermostatic controls
Computers
Air conditioners
14
Models Available
Materials
SWITCH HOUSING: Thermoplastic polyester or high temperature
thermoplastic (PTS) (UL 94V-0).
ACTUATOR BUTTON: Thermoplastic polyester.
SPRING: Copper alloy.
PIVOT: Copper alloy.
MOVABLE CONTACTS: Silver nickel
STATIONARY CONTACTS: Silver nickel on copper alloy.
TERMINALS: Copper alloy.
ACTUATOR LEVEL: Stainless steel.
J
Snap-acting
Build-A-Switch
To order, simply select desired option from each category and place in the appropriate box. Available options are shown and
described on pages J-27 thru J-29. For additional options not shown in catalog, consult Customer Service Center.
L
Series
LCS
Contact Rating
05
5 AMP, 125/250 V AC
6 AMP, 125/250 V AC
01
0.1 AMP, 125/250 V AC
C
S
14
Operating Force
1
150 grams
2
203 grams
Actuator
P00
Pin plunger
T00
0.45 mm short lever
T05
5.05 mm short lever
T07
7.05 mm short lever
T13
13.15 mm lever
T19
20.95 mm lever
T28
28.35 mm lever
T43
43.55 mm lever
S26
6.25 mm simulated lever
A05
4.85 mm lever roller
Circuitry
C
SPDT
W
SPST N.C.
Y
SPST N.O.
Wire Type AWG
20
20 AWG
22
22 AWG
24
24 AWG
26
26 AWG
28
28 AWG
30
30 AWG
Wire UL #
(when required)
A
UL1007
B
UL1015
C
UL1430
D
UL1061
E
UL1330
Terminations
S
Solder
Q
0.110 Quick Connect
P
PC Thru Hole
W
Wire leads potted
Z
Wire leads non-potted
Wire Side (when required)
A
Wire out the bottom
B
Wire out the right side
C
Wire out the left side
D
None
Dimensions are shown: mm
Specifications and dimensions subject to change
J–26
www.ck-components.com
Transparent drawing PNG picture file under Windows CE
I have a PNG image file myfile.png that needs to be displayed on a window. Under Windows XP, there is the CImage class that can handle PNG images, and the CDC TransparentBlt function that handles tran...
shunv424 Embedded System
Switch to LCD display
[Repost] Principle of Liquid Crystal Display Classification of Liquid Crystal Display According to different control methods, liquid crystal displays can be divided into two types: passive matrix LCD ...
天使疯子 Embedded System
When etherOutput is called intensively to send Ethernet frames, an ERROR is returned saying "out of mbufs". How can I solve this problem?
When etherOutput is called intensively to send Ethernet frames, an ERROR is returned saying "out of mbufs". How can I solve this problem?...
6666666 Embedded System
Looking for telephone line transmission protocol or dedicated telephone line signal processing chip
I have to build a fixed-line call firewall (to identify incoming call numbers and block harassing calls) for my internship. I have two ideas: 1. Use a dedicated call signal processing chip; 2. Use a s...
jeery1008 Embedded System
Basic knowledge of Keil C51 development system (1)
Basic knowledge of Keil C51 development system 1. Section 1 System Overview Keil C51 is a 51 series compatible microcontroller C language software development system produced by Keil Software, USA . C...
rain 51mcu
Error: i2cwrite error:1460 Please give me some advice
12c init iic irq mapping :[irq:27->sysIRQ:21]. OEMIoControl:Unspported Code 0x10100b4-device 0x0101 func 52 OEMIoControl:Unspported Code 0x10100b4-device 0x0101 func 62 CamCLOCKOn=1 syncist:IO_Abandon...
chenjc110 Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2456  2882  325  2502  1605  50  59  7  51  33 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号