EEWORLDEEWORLDEEWORLD

Part Number

Search

U5336-02001G-200BG

Description
Peizoresistive Sensor, 0Psi Min, 3000Psi Max, 0.1%, 0.5-4.5V, Cylindrical
CategoryThe sensor   
File Size319KB,8 Pages
ManufacturerTE Connectivity
Websitehttp://www.te.com
Environmental Compliance
Download Datasheet Parametric View All

U5336-02001G-200BG Overview

Peizoresistive Sensor, 0Psi Min, 3000Psi Max, 0.1%, 0.5-4.5V, Cylindrical

U5336-02001G-200BG Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
MakerTE Connectivity
Reach Compliance Codeunknown
Maximum accuracy(%)0.1%
Other featuresPort Height = 13.5 MM
body height58.8 mm
Body length or diameter24 mm
Maximum working current5 mA
Maximum operating temperature125 °C
Minimum operating temperature-40 °C
Output range0.5-4.5V
Output typeVOLTAGE OUTPUT
Package Shape/FormCYLINDRICAL
port typeM14X1.5MM
Maximum pressure range3000 Psi
Minimum pressure range
Pressure sensing modeGAUGE
Sensor/temperature sensor typePRESSURE SENSOR,PIEZORESISTIVE
Maximum supply voltage30 V
Minimum supply voltage5 V
U5300
Industrial Pressure Transducer
SPECIFICATIONS
Superior Accuracy and Total Error Band
Instrument Grade and Compact
Variety of Pressure Ports and Electrical Configurations
Optional Stainless Steel Snubber
CE Compliant and Weatherproof
UL Certified
Gage, Sealed, Absolute, Compound
Expedite Configurations Available (10 Days)
FEATURES
Heavy Industrial CE Approval
10 V/m EMI Protection
Reverse Polarity Protection on Input
Short Circuit Protection on Output
±0.1% Accuracy
±0.5% Total Error Band
Compact Outline
-40°C to +125°C Operating Temperature
Weatherproof
The instrument grade U5300
pressure transducers from the UltraStable line
of MEAS, with their modular design, offer maximum flexibility for different
configurations. This latest series features superior accuracy and total error
band for demanding commercial and heavy industrial applications. This
series is suitable for measurement of liquid or gas pressure, even for difficult
media such as contaminated water, steam, and mildly corrosive fluids.
The wetted material is made of 316L stainless steel and the transducer’s
durability is excellent with no O-rings or organics exposed to the pressure
media. The U5300 is weatherproof and exceeds the latest heavy industrial
CE requirements including surge protection. The circuit is protected from
reverse wiring at input and short circuit at output.
This product is geared to the OEM customer for low to mid volumes. MEAS
stands ready to provide a custom design of the U5300 where the volume and
application warrants. Additional configurations not listed are either available
or possible. Please inquire for further information.
APPLICATIONS
Military/Aerospace Test Stands
Automotive Test Stands
Calibration Equipment
High Accuracy Applications
Stationary Motor Fuel Control
High End Industrial Machinery
SENSOR SOLUTIONS
///U5300
07/2018
Page 1
I owe you all a bowl of rice noodles
When I was supposed to go to bed at this time, my boss called me and asked me to go to the Ministry of Industry and Information Technology to replace other colleagues for a day tomorrow and return to ...
chenzhufly Talking about work
Please look at the problem of this ad conversion circuit
[backcolor=rgb(239, 245, 249)]As shown in the figure, I want to collect the voltage value (0-10V) across a resistor. Now I use this module (ad7705). Its chip input is 0-2.5V. It now uses resistor volt...
冷若寒 ADI Reference Circuit
Two-switch forward converter
In the figure, D1 and D2 diodes are used for 200W power supply and above. How to choose the parameters of the diodes here?...
Brain.Zan Switching Power Supply Study Group
ADSL FAQs
Do you need to dial when using ADSL? What number should you dial?     There are two ways to access the Internet with ADSL: virtual dial-up and dedicated line access. Users who use the virtual dial-up ...
manyi RF/Wirelessly
【Repost】15 Idioms about Crowding on Public Buses
1. [b]A bad start[/b]: After moving, I took the bus to work for the first time. I squeezed for an hour but couldn't get on the bus. 2. [b]The early bird catches the worm[/b]: I got up at 4:30 the next...
lixiaohai8211 Talking
mxchip 1081 wifilink+ adds nearby wifi signal scanning
The demo of version 1.12 detects nearby WiFi signals by pressing a button. I followed its method to remove the button. 1. Define a global variable to use as a flag2. Process the flag in the callback f...
90houyidai RF/Wirelessly

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2294  1138  2248  147  2489  47  23  46  3  51 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号