5145.ABDBF200C0.231

Description
Mains Power Connector, 2A, 125/250VAC, Male, ROHS COMPLIANT
CategoryThe connector    The connector   
File Size543KB,5 Pages
ManufacturerSCHURTER
Websitehttp://www.schurterinc.com/
Environmental Compliance  
Download Datasheet Parametric View All

5145.ABDBF200C0.231 Overview

Mains Power Connector, 2A, 125/250VAC, Male, ROHS COMPLIANT

5145.ABDBF200C0.231 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerSCHURTER
package instructionROHS COMPLIANT
Reach Compliance Codecompliant
Other featuresSTANDARDS: IEC/EN 60320-1/C14; UL 94V-0; CSA; VDE, QUICK CONNECT
Connector typeMAINS POWER CONNECTOR
Contact to complete cooperationTIN/TIN COPPER
Contact completed and terminatedTIN/TIN COPPER
Contact point genderMALE
Contact materialNOT SPECIFIED
Coupling typeSNAP
DIN complianceNO
IEC complianceYES
JESD-609 codee3/e2
MIL complianceNO
Power Connector Ratings2A, 125/250VAC
Installation typePANEL
OptionsGENERAL PURPOSE
Shell materialPOLYETHYLENE
Total number of contacts3
5145
POWER ENTRY MODULES WITH LINE FILTER
Standard- or Medical-Filter
Inlet filter, front side mounting, circuit breaker TA45 2-pole
C14
70° C
Description
- Panel Mount:
Screw-on from front side
- 3 Functions:
Inlet Protection class I, circuit breaker type TA45 2-pole, Line filter in
standard and medical version
- Quick connect terminals 6.3 x 0.8 mm
- Alternative: version without line filter
6145
- We recommend for new applications type
DF12
Characteristics
- All single elements are already wired
Unwired versions available on request
- Line switch non-illuminated or illuminated
Thermal overload protection
Optional with undervoltage release or remote trip release
- Qualified for use in equipment according IEC/EN 60950
Weblinks
Approvals:
http://www.schurter.com/approvals
RoHS:
http://www.schurter.com/rohs
Approvals
- VDE License Number: 117118
- UL License Number: E72928
Technical Data
Ratings IEC
Ratings UL/CSA
Leakage Current
Dielectric Strength
1 - 10 A @ Ta 40 °C / 250 VAC; 50 Hz
1 - 15 A @ Ta 40 °C / 125 VAC; 60 Hz
standard < 0.5 mA (250 V / 60 Hz)
medical < 5 µA (250 V / 60 Hz)
> 1.7 kVDC between L-N
> 2.7 kVDC between L/N-PE
Test voltage (2 sec)
-10 °C to 55 °C
10/055/21acc. to, IEC 60068-1
from front side IP 40 acc. to IEC 60529
Suitable for appliances with protection
class I acc. to IEC 61140
Quick connect terminals 6.3 x 0.8 mm
Screw-on: max 8 mm
Mounting screw torque max 0.5 Nm
Thermoplastic, black, UL 94V-0
Appliance-Inlet /-Outlet
C14 acc. to IEC/EN 60320-1,
UL 498, CSA C22.2 no. 42 (for cold con-
dition) pin-temperature 70 °C, 10 A, Pro-
tection class I
Acc. IEC/EN 60934, UL 1077, CSA 22.2
no. 235
2-pole rocker switch, illuminated or non-il-
luminated. Optional with undervoltage- or
remote trip release
Short circuit capacity Icn:
at In < 3A/240VAC : 10 x In
at In
3A/240VAC : 300A
acc. to IEC 61058-1
Technical details
Standard and Medical Version, IEC
60939, IEC 60601-1, UL 1283, UL 544,
EN 133 200, CSA C22.2 no. 8
Technical details
> 100'000 h acc. to MIL-HB-217 F
Circuit breaker
Allowable Operation Temp.
Climatic Category
Degree of Protection
Protection Class
Terminal
Panel Thickness s
Material: Housing
Line Switch
Line Filter
MTBF
1
www.schurter.com
I will briefly talk about the data flow style of Verilog language style, please don't criticize me
I'm new here, so my writing is not good. I hope you guys won't criticize me! There are 4 description styles in Verilog (I'll talk about the first one today): (1) Data flow style; (2) Behavioral style;...
Crazy_HUA FPGA/CPLD
How is the current carrying capacity of a wire measured? !
I have been thinking about a question: How is the current carrying capacity of a wire measured? The resistance of wires of the same thickness is the same at any voltage; if the current carrying capaci...
eeleader Industrial Control Electronics
I have a question. I have experience in C++ and assembly development on Windows, but I have no foundation in electronics. Where should I start if I want to learn microcontrollers?
I'm here to ask you all for help. I've had experience with C++ and assembly language development on Windows before, but I studied computer science instead of electronics in college, so I don't have an...
davidli88 Embedded System
About the communication procedure between 430F149 and SP12
Dear teachers and seniors, my graduation project involves the connection between these two modules. SP12 is a temperature and pressure sensor. My job is to process the data collected by SP12 through 4...
windows_01 Embedded System
Ask for the program to measure AC voltage using ADC12 inside msp430
I want a program to measure AC voltage using ADC12 inside msp430. Does anyone know how to calculate AC voltage by integration? Please help! :Cry:...
xujuncheng Microcontroller MCU
About 求余%, 乘* 除/ 电影 电影
test_freq[31:0]; base_cnt_reg[31:0]; test_cnt_reg[31:0]; test_freq = 50000000 * test_cnt_reg / base_cnt_reg; test_freq = 50000000 / base_cnt_reg * test_cnt_reg ; What's the difference? These two sente...
wall_e FPGA/CPLD

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2260  1640  2423  159  1752  46  34  49  4  36 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号