EEWORLDEEWORLDEEWORLD

Part Number

Search

F.BQ.MA.3100.ZA.120

Description
Mains Power Connector, 1A, 250V, Male, Solder Terminal, Plug
CategoryThe connector    The connector   
File Size116KB,2 Pages
ManufacturerNissei Electric Co.,Ltd.
Download Datasheet Parametric View All

F.BQ.MA.3100.ZA.120 Overview

Mains Power Connector, 1A, 250V, Male, Solder Terminal, Plug

F.BQ.MA.3100.ZA.120 Parametric

Parameter NameAttribute value
MakerNissei Electric Co.,Ltd.
Reach Compliance Codeunknown
Other featuresSTANDARDS: IEC/EN 60320; VDE; UL, FASTON
Body/casing typePLUG
Connector typeMAINS POWER CONNECTOR
Contact point genderMALE
Coupling typeSCREW
DIN complianceNO
IEC complianceYES
MIL complianceNO
Power Connector Ratings1A, 250V
Manufacturer's serial numberF.BQ
Installation typePANEL
OptionsGENERAL PURPOSE
Termination typeSOLDER
Total number of contacts3
IEC Inlet Filters
With fuse holders
A range of chassis mount IEC 60320 inlet power entry modules which
combine single or twin fuse holders and a high level of suppression,
within a compact and lightweight enclosure.
Cost effective solution for business, consumer, medical
equipment, VDUs, computers, vending machines and many other
general purpose applications.
F.BP-F.BQ-F.CP-F.CQ
series
Snap-in or screw fit
Current ratings from 1A to 10A
Integral single or twin fuse holder
Compact, lightweight design
Medical versions available
Mechanical Specifications
Manufacture:
metal case with built-in power line connector
according to IEC 60320 & EN 60320 and fuse
holder for 1 (F.-P) or 2 (F.-Q) fuses 5 x 20mm (IEC).
Connections:
IEC 60320 - Standard plug (INPUT);
faston 2x2.8 x 0.5mm or 6.3 x 0.8mm (OUTPUT);
ground terminal connected to case.
Mounting:
F.B- screw mounting, F.C- Snap-in mounting.
Climatic category:
Electrical Specifications
Rated voltage (V
R
):
max 250V, 50/60Hz
Rated current (I
R
):
Voltage test (2
S
.):
referred to room temperature = 40°C
line to ground 3000Vdc or 1800Vac
line to line 1700Vdc
HPF (25/085/21):
Temperature range: -25°C to +85°C
Leakage current (I
L
):
at 220V, 50Hz, max value
Filter Range
Code
F.--.AB.2680.ZA.100
F.--.AB.2680.ZB.100
F.--.AB.2680.ZC.100
F.--.AB.2680.ZF.100
F.--.AB.2680.ZG.100
I
R
(A)
1
2
4
6
10
L
(mH)
2x10
2x4
2x1.5
2x0.8
2x0.13
Cx
1
(µF)
0.068
0.068
0.068
0.068
0.068
Cy
(pF)
2x2200
2x2200
2x2200
2x2200
2x2200
I
L
(mA)
2x0.2
2x0.2
2x0.2
2x0.2
2x0.2
Circuit diagram
Only for F.BQ and F.CQ
Available Variants
B = Screw mounting
C = Snap-in mounting
A = Standard Version
M = Medical Version
I
R
, L & CCT.
CCT A VALUES
ZA
1A, 10mH,
ZB
2A, 4mH,
ZC
4A, 1.5mH
ZF
6A, 0.8mH
ZG
10A, 0.13mH
P = Single Fuse
Q = Double Fuse
X Capacitance
2100 = 0.010uF
2470 = 0.047uF
2680 = 0.068uF
3100 = 0.1uF
F. --.-- - - - -. - -. - - 0
A = 2x2.8mm x 0.8 faston
B = 6.3mm x 0.8 faston
Y Capacitance
0 = 2500pF
1 = 2200pF
2 = RESERVED
3 = RESERVED
4 = 150pF
Current Leakage
2x0.23 mA
2x0.20 mA
2x0.014 mA
Resistor
0 = no resistor
1 = 1MΩ
2 = 2.2MΩ
Approvals
24
What to eat for breakfast?
Let me talk about myself first. My alternative is an egg pancake, a pancake, and two or three steamed buns. There is a saying that if you eat breakfast like an emperor, lunch like a commoner, and dinn...
mmmllb Talking
Fps series single chip IC charger design data
Design Example Using FSDH0165/FSDH565 Charger...
lorant Analog electronics
msp430f149 ultrasonic code
I just saw that I won a prize today. I would like to share the ultrasonic code I found today. It is absolutely usable. Welcome to discuss. Many of them are not usable on the Internet. There are three ...
zwhlxl Microcontroller MCU
Regarding the problem of permanently saving registry data! ! Urgent! ! ! !
Hello everyone, I have a question for you: I want to save the registry data permanently: I found an article on the Internet (many articles are about this) 1. Add "Hive-based Registry" in PB. If it is ...
moffice Embedded System
Ask a question, thanks
We have a batch of data received by the sensor and put in a dual-port RAM. How can we mount this dual-port RAM on the external system bus of arm9? Thank you...
wjwbin Embedded System
Ask for help
[i=s] This post was last edited by paulhyde on 2014-9-15 03:21[/i] Help msp430g2553 communicate with TCA6416 using IIC but the interrupt can only be entered once. What is the reason? #include "msp430g...
yishuihan Electronics Design Contest

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 497  1449  191  662  2757  11  30  4  14  56 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号