EEWORLDEEWORLDEEWORLD

Part Number

Search

BK8/AGC-5-B-R

Description
Electric Fuse, Fast Blow, 5A, 200A (IR),
CategoryCircuit protection    Circuit protection   
File Size159KB,2 Pages
ManufacturerEaton
Download Datasheet Parametric View All

BK8/AGC-5-B-R Overview

Electric Fuse, Fast Blow, 5A, 200A (IR),

BK8/AGC-5-B-R Parametric

Parameter NameAttribute value
MakerEaton
Reach Compliance Codecompliant
Fusing characteristicsFAST
body height31.75 mm
Body length or diameter6.35 mm
Circuit protection typeElectric Fuse
physical size6.35mm x 31.75mm
Pre-discharge rating0.04 A2/s
Rated breaking capacity200 A
Rated current5 A
Rated voltage250 V
GuidelineCSA, UL
Terminal shapeEND CAP
1/4" x 1-1/4" Fuses
AGC Series, Fast Acting, Glass Tube
Description
• Fast-acting, glass tube
• Optional axial leads available
• 1/4 x 1-1/4 (6.3mm x 32mm) physical size
• Glass tube, nickel-plated brass endcap construction
• UL Listed product meets standard 248-14
ELECTRICAL CHARACTERISTICS
% of Amp Rating
Opening Time
100%
None
135%
60 Minutes Maximum
200%
120 Seconds Maximum
RoHS
2002/95/EC
Dimensions
(
mm
in
)
Drawing Not to Scale
Agency Information
• UL Listed Card: AGC 1/500-10
• UL Recognition Card: AGC 11-45
• CSA Component Acceptance Card (Class No. 1422 30)
• CSA Certification Card (Class No. 1422 01)
Environmental Data
• Shock: 1/100A thru 3/4A – MIL-STD-202,
Method 213, Test Condition I; 1A thru 30A –
MIL-STD-202, Method 207, (HI Shock)
• Vibration: 1/100A thru 30A – MIL-STD-202,
Method 204, Test Condition A (Except 5g, 500HZ)
Ordering
• Specify packaging, product, and option code
Product Code
AGC-1/20
AGC-1/16
AGC-1/10
AGC-1/8
AGC-3/16
AGC-2/10
AGC-1/4
AGC-3/10
AGC-3/8
AGC-1/2
AGC-3/4
AGC-1
AGC-1-1/4
AGC-1-1/2
AGC-2
AGC-2-1/4
AGC-2-1/2
AGC-3
AGC-4
AGC-5
AGC-6
AGC-7
AGC-7-1/2
AGC-8
AGC-9
AGC-10
AGC-12
AGC-14
AGC-15
AGC-20
AGC-25
AGC-30
AGC-35
AGC-40
Voltage
Rating
AC
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
32V
32V
32V
32V
32V
32V
32V
32V
250V
35A
35A
35A
35A
35A
35A
35A
35A
35A
35A
35A
35A
100A
100A
100A
100A
100A
100A
200A
200A
200A
200A
200A
200A
200A
200A
-
-
-
-
-
-
-
-
AC Interrupting
Rating
125V
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
-
-
-
-
-
-
-
-
SPECIFICATIONS
32V
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
1000A
1000A
1000A
1000A
1000A
1000A
70A
80A
Typical DC Cold
Resistance**
(ohms)
4.500
29.000
12.565
6.800
4.900
3.360
2.300
1.670
1.203
0.615
0.312
0.190
0.145
0.115
0.078
0.067
0.057
0.045
0.030
0.024
0.020
0.017
0.0146
0.014
0.012
0.008
0.0070
0.0062
0.006
0.004
0.003
0.002
0.0014
0.0019
Typical
Melting I
2
t†
AC
0.00773
0.000181
0.000787
0.00131
0.00637
0.00435
0.0148
0.0208
0.0321
0.269
0.815
1.615
0.018
0.0149
0.00509
0.00588
0.00879
0.0167
0.0305
0.045
0.071
0.105
-
0.152
0.21
0.492
-
-
0.566
1.438
2.109
3.807
-
-
Typical
Voltage
Drop‡
0.67
10.41
6.00
4.67
4.12
4.51
0.89
2.88
4.59
0.59
0.37
0.31
0.35
0.27
0.28
0.26
0.31
0.25
0.22
0.23
0.23
0.23
-
0.19
0.18
0.20
-
-
0.14
0.12
0.11
0.12
-
-
** DC Cold Resistance (Measured at
≤10%
of rated current)
† Typical Melting I
2
t (A
2
Sec) (I
2
t was measured at listed interrupting rating and rated voltage.)
‡ Typical Voltage Drop (Voltage drop was measured at 25°C ambient temperature at rated current)
Tangled
These two seminars were actually held on the same day by the same company, so if you register for two seminars, you will be found out. Basically, you can run two seminars because the distance between ...
naga568 Talking
LLAKG: Arduino automatic watering system (Episode 2: C language program and function implementation)
[i=s]This post was last edited by treesbook on 2020-2-8 18:39[/i]This is the second episode. I introduced C language programming and implemented a basic automatic watering function. During the debuggi...
treesbook MCU
STM32 timer compare match problem
RCC->APB1ENR |= RCC_APB1ENR_TIM2EN; TIM2->ARR = 1200; TIM2->CCR1 = 6000; TIM2->CCR2 = 6000; TIM2->CCR3 = 6000; TIM2->CCR4 = 6000; TIM2->DIER = TIM_DIER_CC1IE; TIM2->SR = 0x0000; TIM2->CR1 = TIM_CR1_UD...
enthier stm32/stm8
Gaofen Help! After the system is started, the ResidentFlash folder cannot be seen
I use Wince4.2. After the system is up, I cannot see ResidentFlash. I can see the capacity of the flash in the storage manager, and the unallocated capacity is 0. In the partition information, there i...
wmj0402 Embedded System
What RF signal tests require an oscilloscope?
Why should oscilloscopes be used for RF signal testing? The intuitiveness of time domain measurement A big reason for time domain measurement of RF signals is its intuitiveness. For example, in the ex...
凡实测控 Test/Measurement
Why can't CC2650 play happily?
[i=s]This post was last edited by littleshrimp on 2016-12-22 13:42[/i] Previously I only had CC2650STK (SensorTag). I bought a LAUNCHXL2-RM46 and used the XDS110 on the LAUNCHXL2-RM46 to emulate the C...
littleshrimp TI Technology Forum

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1376  436  707  2123  2262  28  9  15  43  46 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号