EEWORLDEEWORLDEEWORLD

Part Number

Search

5145.A146F150C0.710

Description
Mains Power Connector, 10A, 250/125VAC, Male, Solder Terminal, ROHS COMPLIANT
CategoryThe connector    The connector   
File Size1MB,6 Pages
ManufacturerSCHURTER
Websitehttp://www.schurterinc.com/
Environmental Compliance  
Download Datasheet Parametric View All

5145.A146F150C0.710 Overview

Mains Power Connector, 10A, 250/125VAC, Male, Solder Terminal, ROHS COMPLIANT

5145.A146F150C0.710 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerSCHURTER
package instructionROHS COMPLIANT
Reach Compliance Codecompliant
ECCN codeEAR99
Other featuresSTANDARDS: IEC/EN 60320-1; IEC/EN 60950; UL 94V-0; CSA; VDE; QUICK CONNECT
Connector typeMAINS POWER CONNECTOR
Contact to complete cooperationTIN/TIN COPPER
Contact completed and terminatedTIN/TIN COPPER
Contact point genderMALE
Contact materialNOT SPECIFIED
Coupling typeSNAP
DIN complianceNO
IEC complianceYES
JESD-609 codee3/e2
MIL complianceNO
Power Connector Ratings10A, 250/125VAC
Installation typePANEL
OptionsGENERAL PURPOSE
Shell materialPOLYETHYLENE
Termination typeSOLDER
Total number of contacts3
Power entry modules with line filter
www.schurter.com/pg06
Inlet filter, front side mounting, circuit breaker TA45 2-pole
545
Standard- or Medical-Filter
Screw-On Version
C14
70° C
Description
- Panel Mount:
Screw-on from front side
- 3 Functions:
Appliance Inlet Protection class I, circuit breaker type TA45 2-
pole, Line filter in standard and medical version
- Quick connect terminals 6.3 x 0.8 mm
- Alternative: version without line filter 6145
- We recommend for new applications the new type DF12
Characteristics
- All single elements are already wired
Unwired versions available on request
- Line switch non-illuminated or illuminated
Thermal overload protection
Optional with undervoltage release or remote trip release
- Qualified for use in equipment according IEC/EN 60950
Weblinks
Approvals
Approvals, RoHS, CHINA-RoHS, e-Store, SCHURTER-Stock-Check,
Distributor-Stock-Check
- VDE License Number: 117118
- UL License Number: E72928
Technical Data
Ratings IEC
Ratings UL/CSA
Leakage Current
Dielectric Strength
1 - 10 A @ Ta 40 °C / 250 VAC; 50 Hz
1 - 15 A @ Ta 40 °C / 125 VAC; 60 Hz
standard < 0.5 mA (250 V / 60 Hz)
medical < 5 µA (250 V / 60 Hz)
> 1.7 kVDC between L-N
> 2.7 kVDC between L/N-PE
Test voltage (2 sec)
-10 °C to 55 °C
10/055/21acc. to, IEC 60068-1
from front side IP 40 acc. to IEC 60529
Suitable for appliances with protection
class I acc. to IEC 61140
Quick connect terminals 6.3 x 0.8 mm
Screw-on: max 8 mm
Mounting screw torque max 0.5 Nm
Thermoplastic, black, UL 94V-0
Appliance-Inlet/-Outlet
C14 acc. to IEC/EN 60320-1,
UL 498, CSA C22.2 no. 42 (for cold
conditions) pin-temperature 70 °C, 10 A,
Protection class I
Acc. IEC/EN 60934, UL 1077, CSA
22.2 no. 235
2-pole rocker switch, illuminated or non-
illuminated. Optional with undervoltage-
or remote trip release
Short circuit capacity Icn:
at In < 3A/240VAC : 10 x In
at In ≥ 3A/240VAC : 300A
Rocker switch 2-pole non-illuminated or
illuminated acc. to IEC 61058-1
Technical details
Standard and Medical Version, IEC
60939, IEC 60601-1, UL 1283, UL 544,
EN 133 200, CSA C22.2 no. 8
Technical details
> 100'000 h acc. to MIL-HB-217 F
Circuit breaker
Allowable Operation Temp.
Climatic Category
Degree of Protection
Protection Class
Terminal
Panel Thickness s
Material: Housing
Line Switch
Line Filter
MTBF
EMC products

[Shanghai Hangxin ACM32F070 development board + touch function evaluation board]—— EXTI routine
1.3. EXTI Example The EXIT routine sets EXTI (external interrupt/event controller) and then enters STOP mode, that is, executes WFI/WFENotes:There is a System_Delay_MS(3000); in front of the APP_EXTI_...
mars4zhu Domestic Chip Exchange
[Shanghai Hangxin ACM32F070 development board + touch function evaluation board]—— UART routine
1.4. UART Example Program UART communication modes include LOOP (loop reading the UART status register, and reading and writing the data register according to the status), DMA, INT, etc. And the ABORT...
mars4zhu Domestic Chip Exchange
How to complete PCIe testing in 2 minutes? Watch the live broadcast: Tektronix's new PCIe measurement solution - TMT4
PCI Express is the most commonly used high-speed serial bus, which is widely used in data centers, artificial intelligence, storage and other fields. Traditional PCIe testing usually requires too long...
eric_wang Test/Measurement
Who has used security chips specifically in their products?
Yesterday I saw that National Technology released a new generation of IoT security chip N32S003. It seems that every time a security and encryption chip is born, there is a way to crack it, so are the...
nmg Domestic Chip Exchange
New Matter
The new Matter standard is a seal of approval that smart devices will reliably work together—taking the guesswork out of the consumer purchasing process. In this video, we share how Matter helps solve...
btty038 RF/Wirelessly
When your electronic device is out of warranty, do you repair it or throw it away?
When I was browsing the forum just now, I saw several netizens saying that their electronic devices at home have passed the warranty period. They feel that the cost of finding someone to repair them i...
okhxyyo Talking

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 404  1023  1089  2119  2735  9  21  22  43  56 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号