Compliance to EN55011 (CISPR11), EN55022 (CISPR22) Class B, EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN60601-1-2, EN61000-6-2, EN61204-3, heavy industry level, EN61204-3 medical level, criteria A
521.2K hrs min. MIL-HDBK-217F (25
127*76.2*31mm (L*W*H)
0.26Kg; 63pcs/17.4Kg/1.35CUFT
)
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
5. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
6. Heat Sink HS1,HS2,HS3 can not be shorted.
File Name:RPT-75-SPEC 2012-02-20
75W Triple Output Medical Type
Features :
Universal AC input / Full range
Low leakage current<200uA
R P T- 7 5
series
Protections: Short circuit / Overload / Over voltage
Free air convection for rated power and 23.5CFM forced air
convection for peak load
ANSI/AAMI ES60601-1/IEC60601-1/EN60601-1 medical safety approved
Fixed switching frequency at 65KHz
3 years warranty
SPECIFICATION
MODEL
OUTPUT NUMBER
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
PEAK LOAD (23.5CFM)
OUTPUT
VOLTAGE ADJ. RANGE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
INPUT
EFFICIENCY(Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVERLOAD
PROTECTION
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
SAFETY & WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC
(Note 4)
EMC EMISSION
EMC IMMUNITY
MTBF
OTHERS
DIMENSION
PACKING
RPT-75D
CH1
5V
5A
0.6 ~ 7A
73W
95W
200mVp-p
8.0%
1.0%
3.0%
20ms/115VAC at full load
127 ~ 370VDC
74%
120mVp-p
8.0%
1.0%
3.0%
CH2
24V
1.5A
0.1 ~ 2A
CH3
12V
1A
0.1 ~ 1A
RPT-7503
CH1
3.3V
6A
0.7 ~ 7A
61.8W
81.1W
80mVp-p
------
4.0%
1.0%
+3,-4%
120mVp-p
6.0%
1.0%
+5,-4%
120mVp-p
+10,-6%
1.5%
6.0%
CH2
5V
6A
0 ~ 8A
CH3
12V
1A
0 ~ 1.5A
RIPPLE & NOISE (max.)
Note.2
80mVp-p
CH1:4.75 ~ 5.5V
VOLTAGE TOLERANCE
Note.3
2.0%
0.5%
1.5%
500ms, 30ms/230VAC
80ms/230VAC
90 ~ 264VAC
47 ~ 63Hz
79%
500ms, 30ms/115VAC at full load
1.5A/115VAC
1A/230VAC
COLD START 25A/115VAC
50A/230VAC
Earth leakage current <200uA / 264VAC, Patient leakage current <100uA/264VAC
140 ~ 180% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
CH1: 5.75 ~ 6.75V
CH1: 3.8 ~ 4.45V
Protection type : Shut down o/p voltage, re-power on to recover
-20 ~ +70
(Refer to "Derating Curve")
20 ~ 90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH
0.03%/ (0 ~ 45 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
Compliance to EN55011 (CISPR11), EN55022 (CISPR22) Class B, EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN60601-1-2, EN61000-6-2, EN61204-3, heavy industry level, EN61204-3 medical level, criteria A
521.2K hrs min. MIL-HDBK-217F (25
127*76.2*31mm (L*W*H)
0.26Kg; 63pcs/17.4Kg/1.35CUFT
)
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
5. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
6. Heat Sink HS1,HS2,HS3 can not be shorted.
File Name:RPT-75-SPEC 2012-02-20
75W Triple Output Medical Type
Mechanical Specification
FAN
R P T- 7 5
series
Unit:mm
23.5CFM min.
5.7
15cm
HS3
CN2
CN1
1
2
3
4
5
6
7
8
HS1
64.75
76.2
3
2
1
AC Input Connector (CN1) : JST B3P-VH or equivalent
Pin No.
1
2
3
Assignment
AC/N
No Pin
AC/L
Mating Housing
JST VHR
or equivalent
Terminal
JST SVH-21T-P1.1
or equivalent
HS2
AC FUSE
T2.5/250V
FS2 FS1
4-
5.6
115.8
127
3.8
DC Output Connector (CN2) : JST B8P-VH or equivalent