EEWORLDEEWORLDEEWORLD

Part Number

Search

51725-10000807A0

Description
Board Connector, 39 Contact(s), 4 Row(s), Male, Right Angle, Solder Terminal, Locking
CategoryThe connector    The connector   
File Size230KB,3 Pages
ManufacturerAmphenol
Websitehttp://www.amphenol.com/
Download Datasheet Parametric View All

51725-10000807A0 Overview

Board Connector, 39 Contact(s), 4 Row(s), Male, Right Angle, Solder Terminal, Locking

51725-10000807A0 Parametric

Parameter NameAttribute value
Is it lead-free?Contains lead
Is it Rohs certified?incompatible
MakerAmphenol
Reach Compliance Codecompliant
Other featuresTERMINAL PITCH FOR POWER CONTACTS: 6.35 MM
body width0.574 inch
subject depth0.93 inch
Connector typeBOARD CONNECTOR
Contact arrangementS8P7
Contact to complete cooperationGOLD (30) OVER NICKEL
Contact completed and terminatedTIN LEAD (100) OVER NICKEL
Contact point genderMALE
Contact materialPOWER-COPPER ALLOY; SIGNAL-PHOSPHOR BRONZE
Contact resistance20 mΩ
Contact styleHYBRID
DIN complianceNO
Dielectric withstand voltage2500VDC V
Durability200 Cycles
Filter functionNO
IEC complianceNO
maximum insertion force.973 N
Insulation resistance10000000000 Ω
insulator materialGLASS FILLED THERMOPLASTIC
JESD-609 codee0
MIL complianceNO
Manufacturer's serial number51725
Mixed contactsYES
Installation option 1LOCKING
Installation methodRIGHT ANGLE
Installation typeBOARD
Number of connectorsONE
Number of rows loaded4
Maximum operating temperature125 °C
Minimum operating temperature-55 °C
OptionsGENERAL PURPOSE
reliabilityCOMMERCIAL
Terminal length0.135 inch
Terminal pitch2.54 mm
Termination typeSOLDER
Total number of contacts39
UL Flammability Code94V-0
Evacuation force-minimum value.17792 N
PDM: Rev:L
STATUS:
Released
Printed: Dec 20, 2010
.
Talk about the software phase-locking method of C2000's 2812
[size=4][color=#000080]1. Phase-locked loop The meaning of phase-locked loop is the automatic control of phase synchronization. The automatic control closed-loop system that can complete the phase syn...
Jacktang Microcontroller MCU
Urgent!!! Can I execute .exe files or .dll files in vxworks?
Please help me, I want to use labview to make software, download it to VxWorks operating system and execute it. I don't know if it is feasible! I have never used VxWorks, please give me some advice! !...
f4335088 Real-time operating system RTOS
Can I make a circuit that uses a keyboard to set the forward, reverse and number of revolutions of a stepper motor and use 7404 to drive it?
I want to make a mechanical device to drive a stepper motor. The picture shows 7404, but I am not familiar with this chip. I am also not sure about C1384. Can an expert tell me what the appearance of ...
ylzzly691 Embedded System
PCB wiring via problem
[backcolor=rgb(254, 245, 231)][size=12px]Hi seniors, this is my first time drawing a board, I would like to ask you about the vias. For the convenience of wiring, some device pins are grounded with vi...
lym1210 PCB Design
HTU21 Accuracy Issues
Has anyone used this temperature and humidity sensor? Recently, I found that the accuracy and consistency (the simultaneous measurement of multiple products is called consistency, right?) are problema...
lidonglei1 Sensor
Some questions about structural body segments
static loff_t test_llseek(struct file *filp,loff_t off,int whence); static struct file_operation test_fops= { owner:THIS_MODULE, llseek:test_llseek, } To be clear, loff_t is a redefined data type for ...
534117403 Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1824  1806  698  436  1077  37  15  9  22  24 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号