Space saving with scoop proof connector for harsh and EMI applications.
A compact solution
Diameter up to 45% smaller than D38999 size 9.
Integrated backshell: up to 50% shorter.
A high density solution
With #26 contacts (according 39029).
6 layouts (size 3, 5 and 7 with #22 & #26).
Excellent features
Designed for D38999 requirements.
IP67 sealing when mated.
Ballseal (EMI).
RoHS and Cadmium free
Available in zinc nickel (RoHS) plating, as well
as nickel and olive drab cadmium.
Not QPL listed.
8BA Series
|
Break Away
Description
• A compact solution
- The smallest connector available on the
market (shell size 3)
- Break away: quick disconnect
- Integrated backshell:
. Easy to wire and handle
. Compatible with heat shrink boot and
braid retention band
. Compliant with overmolding
• A versatile solution
- 3 shells sizes: 3, 5, 7
- Plug; In line and jam nut receptacle
- Crimp & PC tails contacts (on request)
- Removable contacts #22D & #26
- 6 keyings
• Harsh environment-resistant solution
- Scoop Proof (when sockets mounted into
receptacle only)
- Cavity to cavity sealed with interfacial seal
and grommet
- Fluid resistant
Technical features
Mechanical
• Shell:
Aluminum alloy
• Shell plating:
Aluminum:
. Zinc nickel (RoHS)
. Nickel (RoHS)
. Olive drab cadmium
• Insulator:
Thermoplastic
• Contact body:
Copper alloy
• Contacts plating:
Gold over nickel plated
• Shell endurance:
Aluminum:
500 mating/unmating cycles
• Vibration:
30 grms ambiant, 2 axes during 8 hours
• Shock:
300g, 3 ms
Electrical
• Wire size
Layouts
03-05; 05-06;
07-09
03-35; 05-35;
07-35
Wire (AWG)
24-30
22-28
Environmental
• Temperature range:
-55°C to +175°C
• Water immersion:
IP 67 on mated connector
1 meter for 30 min minimum
> IP68 with appropriate cable termination
• Salt spray:
Zinc nickel: 500 hours
Nickel: 48 hours
Olive drab cadmium: 500 hours
• Test voltage (at sea level):
Size 22D: 1000 Vrms
Size 26: 400 Vrms
• Contact resistance:
Size 22D: <14.6 mΩ
• Contact rating:
Size 22D: 5A
Size 26: <16 mΩ
Resistance to fluids
• According to MIL-DTL-38999 standard
Gasoline: JP5 (OTAN F44)
Mineral hydraulic fluid: MIL-H-5606
(OTAN H515)
Synthetic hydraulic fluid: Skydrol 500 B4
• Compatible with de-icing fluids containing
potassium acetate
Size 26: 3A
• Contact retention:
Size 22D: 45N Size 26: 30N
• Shell to shell continuity (typical value)
Shell
size
3
5
7
Aluminum
version
10 mΩ
• EMI:
Aluminum: -70dB @ 1GHz
2
8BA Series
|
Break Away
Shell types
Plug
For other configuration or PC tail version, please consult us.
In line receptacle
Jam nut receptacle
Contact layouts
03
05
35
05
06
35
07
09
35
Size 3: Marking on shell.
Rear view of receptacle for male and
female insulator.
Opposite marking between plug and
receptacle.
Sizes 5 and 7: Marking on insulator.
Rear view of male insulator for plug
and receptacle.
Opposite marking between male and
female insulator.
5#26
3#22D
6#26
3#22D
9#26
5#22D
Ordering information
Basic Series
Shell type:
1:
In line receptacle
6:
Plug
7:
Jam nut receptacle
Shell size: 03, 05, 07
Plating :
Z:
Black zinc nickel
F:
Nickel
W:
Olive drab cadmium
Contact layouts:
See above
Contact type:
P:
Pin
S:
Socket (Scoop proof only when socket contacts mounted in Type 1 & Type 7)
Orientation: N, A, B, C, D, E
(see page 5)
8BA
1
03
W
05
P
N
3
8BA Series
|
Break Away
Dimensions
Plug - Shell type 6
B
B
Shell
size
D
A
A
D
3
5
C
Shell size 3 & 5
Shell size 7
C
7
A
10.3
12.2
14.3
B Max
18.4
19.4
24
C Max ØD Max
6.1
6.1
6.1
7.3
8.9
10
In line receptacle - Shell type 1
B
Shell size
3
A
D
5
7
C
A
11
12.8
14.3
B Max
17.7
19.1
24
C Max ØD Max
6.1
6.1
6.1
7.3
9
10
Jam nut receptacle - Shell type 7
B
D
B
D
G
A
A
F
F
H
E
C
Thread
Panel
thickness
Thread
E
C
Panel
thickness
Shell size 3
Shell size
3
5
7
Thread
7/16’’28 UNEF 2A
1/2’’28 UNEF 2A
9/16’’24 UNEF 2A
A Max
10.55
12.2
13.6
Shell size 5 & 7
B Max
17.7
22.5
24
C Max
3.2
3.2
3.2
D
1.75
±0.3
1.75
±0.3
1.75
±0.3
E Max ØF Max ØG Max
6.1
6.1
6.1
7.3
8.9
10
17.5
19.5
21
ØH
Panel cut out
J
11.3
±0.1
10.6
±0.05
12.8
±0.1
12.3
±0.05
14.5
±0.1
13.8
±0.05
Note: All dimensions are in millimeters (mm)
J
4
8BA Series
|
Break Away
Orientations
Shell size 3
Master Key
Shell sizes 5 & 7
Master Key
X°
Y°
Shell
size
3
5&7
Angles
X°
Y°
Z°
N
153
145
75
A
51
130
120
B
102
110
120
C
204
155
115
D
255
90
115
E
306
90
180
Z°
Viewed from front face of plug
Connector weights
Aluminum version -
in gram ±10 %
Shell size
& layout
3-05
5-06
7-09
Plug
Without contacts
1.7
2.6
4.3
With crimp contacts
1.8
2.8
4.7
In line receptacle
Without contacts
1.3
2.9
4.7
With crimp contacts
1.4
3.1
5.1
For further information contact us at
contactmilaero@souriau.com
or visit our web site
www.souriau.com
5
All information in this document presents only general particulars and shall not form part of any contract. All rights reserved to SOURIAU for changes without prior notification or public announcement. Any duplication is prohibited, unless approved in writing.
Now I use 24C02 as a power-off protection chip, and need to write data into 24C02 when the power is off. But now there is a problem, I don't know if it is written incorrectly or read incorrectly, the ...
I want to make a DVB-T player and use TCPMP to modify it, but TCPMP has too much content and I don't know where to start. So I want to buy a way to play real-time data with TCPMP. Or the DVB-T player ...
I bought a circuit board with only one micro power connector. I want to use a battery (3.6V) for power supply. I can add a set of pin headers, and then connect the positive and negative poles of the b...
第一窗体
using System;
using System.Collections.Generic;
using System.ComponentModel;
using System.Data;
using System.Drawing;
using System.Text;
using System.Windows.Forms;namespace wince5
{public partia...
The key is to get the window handle of today's plug-in, right? Today's plug-in DLL is automatically loaded by mobile5.0, but in the DLL, the registration of the window class and the creation of the wi...
PV DC fuses are safety devices used to protect PV panels, inverters, and DC loads. To ensure their safety and reliability, they must be UL248 certified.
Before applying for UL248 certifi...[Details]
With the booming electronics industry, vision systems have become a leader in the electronics automation sector. However, the delicate nature of electronic products often affects product yields due...[Details]
A vacuum eutectic furnace is a critical piece of equipment used in the manufacturing and processing of various materials, particularly in the fields of microelectronics and nanotechnology. One of t...[Details]
Electric vehicles are currently gaining momentum, but this is just a facade. Fuel-powered vehicles remain unchallenged. While electric vehicles boast unique advantages in environmental emissions an...[Details]
On August 24th, media outlets reported, citing sources, that NavInfo, a listed company on the A-share market, is nearing completion in its acquisition of the intelligent driving c...[Details]
To understand why car engines need gearboxes, we must first understand the characteristics of different types of engines. An engine refers to a machine that can convert a form of energy into kineti...[Details]
Is pure electric vehicles a false proposition for long-distance driving? At least from my personal perspective, based on current technological and infrastructure standards, I believe so. Below, I'l...[Details]
Topics: Bring Your Own Device (BYOD) trends; the impact of using employees' own mobile devices to control access to work facilities and equipment on information security; and ways to securely imple...[Details]
Limited vocabulary recognition
According to the number of characters, words or short sentences in the vocabulary, it can be roughly divided into: less than 100 is small vocabulary; 100-1000 is...[Details]
Introduction to the principles of speech recognition technology
Automatic speech recognition (ASR) technology aims to enable computers to understand human speech and extract the textual inform...[Details]
Zos Automotive Research Institute released the "2025
Smart Cockpit
Tier 1 Research Report (Domestic Edition)."
This report analyzes the operating conditions of more than a dozen ...[Details]
With the rapid advancement of automation technology, collaboration between robots is no longer just science fiction. Imagine dozens of machines moving goods in a warehouse without interfering with ...[Details]
On August 18th, Galaxis, a specialist in integrated intelligent intralogistics robotics, officially unveiled its next-generation, ultra-narrow aisle forklift mobile robot, the "VFR Ultra-Narrow Ser...[Details]
According to foreign media reports, Nissan Motor has recently reached a cooperation with US battery technology company LiCAP Technologies to jointly promote the research and development of next-gen...[Details]
Permanent magnets are essential components in a wide range of household and industrial devices. They are particularly crucial in the renewable energy sector, including electric vehicle motors. Curr...[Details]