BK/S-8002-8

Description
BARRIER STRIP TERMINAL BLOCK, 1 ROW, 1 DECK
CategoryThe connector   
File Size78KB,1 Pages
ManufacturerCooper Industries
Download Datasheet Parametric View All

BK/S-8002-8 Overview

BARRIER STRIP TERMINAL BLOCK, 1 ROW, 1 DECK

BK/S-8002-8 Parametric

Parameter NameAttribute value
MakerCooper Industries
Reach Compliance Codeunknown
ECCN codeEAR99
Other featuresTHERMOPLASTIC
Fastening methodSCREW
Manufacturer's serial number8000
Installation typeDIN RAIL
Number of layers1
Rows1
Number of channels8
Rated voltage300 V
safety certificateUL; CSA
Terminal and terminal strip typesBARRIER STRIP TERMINAL BLOCK
FUSE BLOCKS FOR MIDGET
AND ELECTRONIC FUSES
Catalog Number 3835 Series
MULTIPLE POLE FUSEBLOCKS:
3835 Series:
For 13/32" x 1-1/2" (10.3mm x 28.1mm) fuses.
Ampere Rating:
30 Amps
Voltage Rating:
250 volts
Material:
Silver-plated, beryllium copper clips.
No side barriers. Screw terminals.
Phenolic base.
Catalog Number 8000 Series
BOLT-IN AND SNAP-IN MOUNTING FUSEBLOCKS:
For 1/4" x 1-1/4" fuses.
Blocks are molded flame retarded
thermopastic. Clips are spring-bronze.
Voltage Rating:
300V
Agency Approvals:
UL Recognized under Components Program; File E14853A,
Guide IZLT2
CSA Certified Class 6225-01, File 47235
Anti-Rotation Pin:
Single-pole blocks may be ordered
without the antirotational pin simply
by adding an “X” to the number of
poles (Example: BK/S-8001-1X).
Carton Quantity:
10; shelf package: 100.
Bulk Carton:
Single-pole and 2-pole fuse blocks
— 1,000; Multiple-pole fuse blocks
— 3-8 pole: 200; 9-12 pole: 50.
When ordering bulk quantities, prefix “BK/” to catalog
number: (Example: BK/S-8001-1SNP).
Bolt-in Mounting
Series
8000
8100
Terminal
Solder
3/16" Quick
Connect
1/4" Quick
Connect
Screw
Amperes
UL 25A
CSA 21A
UL 20A
CSA 16A
UL 20A
CSA 16A
UL 30A
CSA 10A
Amperes
UL 25A
CSA 21A
UL 20A
CSA 16A
UL 20A
CSA 16A
Angle
40°
40°
40°
Side
*Basic
Cat. No.
S-8001-
S-8002-
S-8101-
S-8102-
S-8201-
S-8202-
S-8203-
S-8301-
Poles
(Suffix)
Construction:
Catalog Data
Catalog
Number
3835-1
3835-2
3835-3
3835-4
3835-5
3835-6
3835-7
3835-8
3835-9
3835-10
3835-12
No. of
Poles
1
2
3
4
5
6
7
8
9
10
12
Base Length
Inches
27/32
1-13/16
2-25/32
3-3/4
4-23/32
5-11/16
6-21/32
7-5/8
8-19/32
9-9/16
11-1/2
mm
21.4
46.0
70.6
95.2
119.9
144.5
169.0
193.7
218.8
242.9
292.1
*Base width — 2-3/4" (69.9mm)
1 - 12
2.75"
(69.9mm)
8200
8301
1.0"
(25.4mm)
Snap-in Mounting
(Poles available in single-pole only)
0.25"
(6.4mm)
Series
8000
8100
Terminal
Solder
3/16" Quick
Connect
1/4" Quick
Connect
Angle
40°
40°
Side
Cat. No.
S-8001-1-SNP
S-8002-1-SNP
S-8101-1-SNP
S-8102-1-SNP
S-8201-1-SNP
S-8203-1-SNP
NOTE:
Mounting screw hole diameter is 0.148" (3.7mm).
Countersink, 0.313" (7.9mm). Max. Mounting scrw No. 6.
8200
Catalog Code
BK/
Prefix for Bulk Packing
Series 8000 Produce Line
Type Terminal
“0”-Solder; “1”-3/16"
Quick Connect; “2”-1/4"
Quick Connect; “3”-Screw
Terminal Angle
“01”-straight (0‚); “02”-40°; “03”-side*
Number of Poles (01-12)
S-8
0
00
-00
155
[Weekly in-depth topic (testing the waters)] What is the core of digital circuits?
I applied for a moderator position and hope to bring everyone a harmonious, comfortable, useful and thought-provoking section. I don't have much experience, so I can only try. I hope everyone will sup...
风过琴弦 MCU
Help: I turned off DHCP in boot, why do I need to apply for a dynamic IP?
: I disabled the DHCP item in BOOT, but when I downloaded from the Internet, I still applied for a dynamic IP. I have already assigned a static IP, 192.168.1.222, and no other machine in the network o...
明枫 Embedded System
Aniu Ge Series Stories: Spider-Man Climbs the Tower of Babel (Smart Grid)
Brother Niu has been paying attention to the transformation of smart grids and the new round of bidding for smart meters. Smart grids are an important part of the renewable energy transmission process...
jameswangsynnex Energy Infrastructure?
Help: The input is a square wave, but the output is deformed as shown in the figure. Why?
The input is a square wave, but the output is deformed as shown in the figure. Why?...
wensir Analog electronics
I need help with 3 windows ce.net issues.
The first is that I have debugged the SDK on my own machine, and it can pass the simulation and run, but when I copy it to the ARM machine, it always prompts that the correct file path is required or ...
nanopiggy Embedded System
How to distinguish between active and passive buzzers?
[i=s]This post was last edited by fish001 on 2018-8-28 22:27[/i] [size=4] A small buzzer currently sold on the market is widely used in various electrical equipment, electronic production, and circuit...
fish001 Analogue and Mixed Signal

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2785  1888  849  1338  2802  57  39  18  27  5 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号