AF117A-06-74

Description
Variable Attenuator, 0MHz Min, 16000MHz Max, 0.5dB Insertion Loss-Max
CategoryWireless rf/communication    Radio frequency and microwave   
File Size236KB,3 Pages
ManufacturerCobham Semiconductor Solutions
Download Datasheet Parametric View All

AF117A-06-74 Overview

Variable Attenuator, 0MHz Min, 16000MHz Max, 0.5dB Insertion Loss-Max

AF117A-06-74 Parametric

Parameter NameAttribute value
Is it Rohs certified?incompatible
MakerCobham Semiconductor Solutions
Reach Compliance Codeunknown
Other featuresTNC-F; N-M, HIGH RELIABILITY, I/P POWER-MAX(PEAK)=200W
Nominal attenuation6 dB
Characteristic impedance50 Ω
structureCOAXIAL
Maximum input power (CW)33.01 dBm
Maximum insertion loss0.5 dB
Maximum operating frequency16000 MHz
Minimum operating frequency
Maximum operating temperature54 °C
Minimum operating temperature
RF/Microwave Device TypesVARIABLE ATTENUATOR
Maximum voltage standing wave ratio1.7
Model 115A thru 119A
Manual Step Attenuators
Choice of Type N, TNC, SMA Connector
dc to 18.0 GHz
2 Watt
Specifications
NOMINAL IMPEDANCE:
50
FREQUENCY RANGE (add Model No. Prefix to
Designate Range):
All Models:
dc to 4.0 GHz (AC)
dc to 18.0 GHz (AF)*
*dc to 16.0 GHz for TNC connector
STANDARD INCREMENTAL ATTENUATION RANGE:
Model 115A:
0 to 9 dB in 1 dB steps
Model 116A:
0 to 60 dB in 10 dB steps
Model 117A:
0 to 69 dB in 1 dB steps
Model 118A:
0 to 90 dB in 10 dB steps
Model 119A:
0 to 99 dB in 1 dB steps
MAXIMUM SWR (Models 117A & 119A):
Frequency
Range (GHz)
dc - 4
dc - 18
SMA, N
1.35
1.70
TNC
1.35
1.70
Features
o
Safety Mechanical Stop
- A mechanical stop between
maximum and 0 attenuation positions on all models
prevents damage to the mechanical drive as well as
preventing large power changes that could cause dam-
age to sensitive equipment.
o
Choice of Attenuation Ranges
- Five standard atten-
uation ranges are available: 0-9 dB, 0-69 dB, and 0-99
dB in 1 dB steps, and 0-60 dB and 0-90 dB in 10 dB
steps.
o
Broadband
- All models are available in a choice of 3
frequency ranges: dc-4, dc-12.4, and dc-18 GHz (dc-16
for units with TNC connector).
o
Right-Angle Drive
- The center conductor of the con-
nector is perpendicular to the control shaft, offering
greater flexibility of applications: panel mounting or
bench setup. All models are bidirectional.
o
Custom Configurations Available Upon Request.
o
Low Deviation from Nominal Value
- These Mini Step
Attenuators have flat frequency response over speci-
fied bands and excellent attenuation accuracy.
Deviation from nominal value is low at all settings.
o
Excellent Repeatability and Long Life Switch
-
Repeatability is better than 0.05 dB to 18.0 GHz for
over 1,000,000 switchings of the drum.
MAXIMUM SWR (Models 115A, 116A, & 118A):
Frequency
Range (GHz)
dc - 4
dc - 18
SMA, N
1.25
1.60
TNC
1.30
1.60
Description
The Weinschel Corporation Models 115A through 119A are
a series of broadband, step attenuators in a right-angle
drive configuration, where the center conductor of the con-
nector is perpendicular to the control shaft. They feature
excellent performance characteristics suitable for use in
high reliability 50 ohm systems and applications requiring
extra-small components for the precision control of power in
discrete steps. They can be used either as input or output
attenuators in signal sources, receivers, field strength
meters, spectrum analyzers, etc.
POWER RATING:
2 watts
average
to 25°C ambient
temperature, derated linearly to 1 watt @ 54°C. 200 watts
peak
(5
µsec
pulse width; 0.5% duty cycle)
POWER COEFFICIENT:
< 0.005/dB/dB/watt
TEMPERATURE COEFFICIENT:
< 0.0004/dB/dB/°C
TEMPERATURE RANGE:
Operating:
0°C to +54°C
Nonoperating: -54°C to +54°C
INCREMENTAL PHASE SHIFT:
~0.5° per dB x f(GHz)
REPEATABILITY:
Better than 0.05 dB across frequency
band for switch life.
SWITCH LIFE:
Over 1,000,000 steps
INDEXING:
36°
5305 Spectrum Drive, Frederick, MD 21703-7362 TEL: 301-846-9222, 800-638-2048
web: www.weinschel.com email: sales@weinschel.com
Fax: 301-846-9116
4/30/02
119
Taxi Fare Meter Based on CPLD/FPGA
Abstract: This paper introduces the composition and working principle of the taxi meter system, and briefly describes the design concept and implementation process of the digital system using a single...
songbo FPGA/CPLD
Electrical control problems
1. Use a self-resetting normally open button; 2. You can use any number of relays (ordinary relays). Requirements: Control a light bulb. Press the button once, the light turns on; press it again, the ...
huchuan987 MCU
Why are the components on the Siemens PS307 power supply so difficult to remove?
I would like to ask why the plug-in components on the Siemens PS307 power supply circuit board are so difficult to remove. I used a constant temperature soldering iron to remove them for a long time, ...
sunboy25 Power technology
Pingtou Ge RVB2601 Review: Introduction to OLED and LVGL Transplantation
1. Introduction to OLED: Our screen uses a resolution of 128*64 , and the driver IC should be SSD1306 , which just supports 129*64 , but it is a monochrome screen and uses the spi interface.首先初始化io口:c...
xiyue521 Domestic Chip Exchange
Looking for the simplest player source code developed using DirectShow
I'm begging for a source code of a video player made with DirectShow on WinCE. As long as it can play, with images and sounds, it's fine. It can be made with EVC or Visual 2005, etc. I hope someone wh...
孤帆 Embedded System
Is there a big difference between uc/osii and uc/osiii?
Dear experts, is there a big difference between uc/osii and uc/osiii?...
1021352522 Real-time operating system RTOS

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 196  541  1718  372  256  4  11  35  8  6 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号