EEWORLDEEWORLDEEWORLD

Part Number

Search

5962R1320801VXC

Description
ADC, Proprietary Method,
CategoryAnalog mixed-signal IC    converter   
File Size142KB,4 Pages
ManufacturerDefense Logistics Agency
Related ProductsFound3parts with similar functions to 5962R1320801VXC
Download Datasheet Parametric View All

5962R1320801VXC Online Shopping

Suppliers Part Number Price MOQ In stock  
5962R1320801VXC - - View Buy Now

5962R1320801VXC Overview

ADC, Proprietary Method,

5962R1320801VXC Parametric

Parameter NameAttribute value
MakerDefense Logistics Agency
package instruction,
Reach Compliance Codeunknown
ECCN code3A001.A.2.C
Converter typeADC, PROPRIETARY METHOD
Output bit codeOFFSET BINARY
Peak Reflow Temperature (Celsius)NOT SPECIFIED
Certification statusQualified
Maximum time at peak reflow temperatureNOT SPECIFIED
Application Note
SLVK047 – May 2020
Single-Event Effects (SEE) Confidence Interval
Calculations
ABSTRACT
This application note describes the methodology used to calculate confidence intervals for radiation-
hardened devices that exhibit few or zero radiation-induced events.
Contents
1
2
Introduction
...................................................................................................................
1
References
...................................................................................................................
3
List of Tables
1
Experimental Example Calculation of Mean-Fluence-to-Failure (MFTF) and,
σ
Using a 95% Confidence
Interval
........................................................................................................................
2
1
Introduction
Determining the SEE cross-section of robustly radiation-hardened devices becomes more difficult since
often few, or possibly even no events are observed during an entire exposure. Determining the cross-
section using an average event rate with standard deviation is no longer a viable option, and the common
practice of assuming a single error occurred at the conclusion of a null-result can end up in a greatly
underestimated cross-section.
In cases where observed events are rare or non-existent, the use of confidence intervals and the Chi-
Squared distribution is indicated. The Chi-Squared distribution is particularly well-suited for determining a
reliability level when the events occur at a constant rate. In the case of SEE testing where the ion events
are random in time and position within the irradiation area, it is expected that the event rate is independent
of time (presuming that parametric shifts induced by the total ionizing dose do not affect the failure rate),
so the use of Chi-Squared statistical techniques is valid (since events are rare an exponential or Poisson
distribution is usually used).
In a typical SEE experiment, the device-under-test (DUT) is exposed to a known, fixed fluence (ions/cm
2
)
while the DUT is monitored for events. This is analogous to fixed-time reliability testing and, more
specifically, time-terminated testing, where the reliability test is terminated after a fixed amount of time
whether or not a failure has occurred (in the case of SEE tests, fluence is substituted for time and hence it
is a fixed fluence test) [1]. Calculating a confidence interval specifically provides a range of values which is
likely to contain the parameter of interest (the actual number of events/fluence). Confidence intervals are
constructed at a specific confidence level. For example, a 95% confidence level implies that if a given
number of units was sampled numerous times and a confidence interval was estimated for each test, the
resulting set of confidence intervals would bracket the true population parameter in about 95% of the
cases.
To estimate the cross-section from a null-result (no events observed for a given fluence) with a confidence
interval, start with the standard reliability determination of lower-bound (minimum) mean-time-to-failure for
fixed-time testing (an exponential distribution is assumed):
SLVK047 – May 2020
Submit Documentation Feedback
Single-Event Effects Confidence Interval Calculations
Copyright © 2020, Texas Instruments Incorporated
1

5962R1320801VXC Similar Products

Part Number Manufacturer Description
ADS5474MHFGV Texas Instruments(德州仪器) 14-Bit, 400-MSPS Analog-to-Digital Converter (ADC) 84-CFP -55 to 125
ADS5474HFG/EM Texas Instruments(德州仪器) Analog to Digital Converters - ADC 14 BIT 400 MSPS ANALOG-TO-DIGITAL CONVERTER 84-CFP 25 Only
5962R1320801VXC Texas Instruments(德州仪器) 14-Bit, 400-MSPS Analog-to-Digital Converter (ADC) 84-CFP -55 to 125

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2536  530  1738  266  1996  52  11  35  6  41 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号