Space saving with scoop proof connector for harsh and EMI applications.
A compact solution
Diameter up to 45% smaller than D38999 size 9.
Integrated backshell: up to 50% shorter.
A high density solution
With #26 contacts (according 39029).
6 layouts (size 3, 5 and 7 with #22 & #26).
Excellent features
Designed for D38999 requirements.
IP67 sealing when mated.
Ballseal (EMI).
RoHS and Cadmium free
Available in zinc nickel (RoHS) plating, as well
as nickel and olive drab cadmium.
Not QPL listed.
8BA Series
|
Break Away
Description
• A compact solution
- The smallest connector available on the
market (shell size 3)
- Break away: quick disconnect
- Integrated backshell:
. Easy to wire and handle
. Compatible with heat shrink boot and
braid retention band
. Compliant with overmolding
• A versatile solution
- 3 shells sizes: 3, 5, 7
- Plug; In line and jam nut receptacle
- Crimp & PC tails contacts (on request)
- Removable contacts #22D & #26
- 6 keyings
• Harsh environment-resistant solution
- Scoop Proof (when sockets mounted into
receptacle only)
- Cavity to cavity sealed with interfacial seal
and grommet
- Fluid resistant
Technical features
Mechanical
• Shell:
Aluminum alloy
• Shell plating:
Aluminum:
. Zinc nickel (RoHS)
. Nickel (RoHS)
. Olive drab cadmium
• Insulator:
Thermoplastic
• Contact body:
Copper alloy
• Contacts plating:
Gold over nickel plated
• Shell endurance:
Aluminum:
500 mating/unmating cycles
• Vibration:
30 grms ambiant, 2 axes during 8 hours
• Shock:
300g, 3 ms
Electrical
• Wire size
Layouts
03-05; 05-06;
07-09
03-35; 05-35;
07-35
Wire (AWG)
24-30
22-28
Environmental
• Temperature range:
-55°C to +175°C
• Water immersion:
IP 67 on mated connector
1 meter for 30 min minimum
> IP68 with appropriate cable termination
• Salt spray:
Zinc nickel: 500 hours
Nickel: 48 hours
Olive drab cadmium: 500 hours
• Test voltage (at sea level):
Size 22D: 1000 Vrms
Size 26: 400 Vrms
• Contact resistance:
Size 22D: <14.6 mΩ
• Contact rating:
Size 22D: 5A
Size 26: <16 mΩ
Resistance to fluids
• According to MIL-DTL-38999 standard
Gasoline: JP5 (OTAN F44)
Mineral hydraulic fluid: MIL-H-5606
(OTAN H515)
Synthetic hydraulic fluid: Skydrol 500 B4
• Compatible with de-icing fluids containing
potassium acetate
Size 26: 3A
• Contact retention:
Size 22D: 45N Size 26: 30N
• Shell to shell continuity (typical value)
Shell
size
3
5
7
Aluminum
version
10 mΩ
• EMI:
Aluminum: -70dB @ 1GHz
2
8BA Series
|
Break Away
Shell types
Plug
For other configuration or PC tail version, please consult us.
In line receptacle
Jam nut receptacle
Contact layouts
03
05
35
05
06
35
07
09
35
Size 3: Marking on shell.
Rear view of receptacle for male and
female insulator.
Opposite marking between plug and
receptacle.
Sizes 5 and 7: Marking on insulator.
Rear view of male insulator for plug
and receptacle.
Opposite marking between male and
female insulator.
5#26
3#22D
6#26
3#22D
9#26
5#22D
Ordering information
Basic Series
Shell type:
1:
In line receptacle
6:
Plug
7:
Jam nut receptacle
Shell size: 03, 05, 07
Plating :
Z:
Black zinc nickel
F:
Nickel
W:
Olive drab cadmium
Contact layouts:
See above
Contact type:
P:
Pin
S:
Socket (Scoop proof only when socket contacts mounted in Type 1 & Type 7)
Orientation: N, A, B, C, D, E
(see page 5)
8BA
1
03
W
05
P
N
3
8BA Series
|
Break Away
Dimensions
Plug - Shell type 6
B
B
Shell
size
D
A
A
D
3
5
C
Shell size 3 & 5
Shell size 7
C
7
A
10.3
12.2
14.3
B Max
18.4
19.4
24
C Max ØD Max
6.1
6.1
6.1
7.3
8.9
10
In line receptacle - Shell type 1
B
Shell size
3
A
D
5
7
C
A
11
12.8
14.3
B Max
17.7
19.1
24
C Max ØD Max
6.1
6.1
6.1
7.3
9
10
Jam nut receptacle - Shell type 7
B
D
B
D
G
A
A
F
F
H
E
C
Thread
Panel
thickness
Thread
E
C
Panel
thickness
Shell size 3
Shell size
3
5
7
Thread
7/16’’28 UNEF 2A
1/2’’28 UNEF 2A
9/16’’24 UNEF 2A
A Max
10.55
12.2
13.6
Shell size 5 & 7
B Max
17.7
22.5
24
C Max
3.2
3.2
3.2
D
1.75
±0.3
1.75
±0.3
1.75
±0.3
E Max ØF Max ØG Max
6.1
6.1
6.1
7.3
8.9
10
17.5
19.5
21
ØH
Panel cut out
J
11.3
±0.1
10.6
±0.05
12.8
±0.1
12.3
±0.05
14.5
±0.1
13.8
±0.05
Note: All dimensions are in millimeters (mm)
J
4
8BA Series
|
Break Away
Orientations
Shell size 3
Master Key
Shell sizes 5 & 7
Master Key
X°
Y°
Shell
size
3
5&7
Angles
X°
Y°
Z°
N
153
145
75
A
51
130
120
B
102
110
120
C
204
155
115
D
255
90
115
E
306
90
180
Z°
Viewed from front face of plug
Connector weights
Aluminum version -
in gram ±10 %
Shell size
& layout
3-05
5-06
7-09
Plug
Without contacts
1.7
2.6
4.3
With crimp contacts
1.8
2.8
4.7
In line receptacle
Without contacts
1.3
2.9
4.7
With crimp contacts
1.4
3.1
5.1
For further information contact us at
contactmilaero@souriau.com
or visit our web site
www.souriau.com
5
All information in this document presents only general particulars and shall not form part of any contract. All rights reserved to SOURIAU for changes without prior notification or public announcement. Any duplication is prohibited, unless approved in writing.
Figure 1 shows the integrated operational amplifier power supply overvoltage protection circuit. When the actual power supply voltage of the operational amplifier circuit block is high, or the power s...
Through the mobile phone with Bluetooth function, the Bluetooth car system can realize many creative applications such as automatic car fault diagnosis, electronic navigation, etc. This article introd...
ADCINT1 and ADCINT2 in PIE have two locations in the PIE table, INT4.y and INT10.y. You can use INT4 or INT10, but there is a difference between the two. One has a high interrupt priority and the othe...
In recent years, with the increasing demand for manufacturing and automated production management, industrial barcode scanners have gradually become an indispensable part of the industrial manufact...[Details]
Reflow soldering, a common soldering method in modern electronics manufacturing, primarily melts solder paste and pads to form solder joints. With technological advancements, soldering equipment ha...[Details]
To understand why car engines need gearboxes, we must first understand the characteristics of different types of engines. An engine refers to a machine that can convert a form of energy into kineti...[Details]
Long ago, the lifespan of cars in my country was 15 years. Once a car reached 15 years old, it was forced to be scrapped. However, the policy was later changed. As long as the car does not exceed 6...[Details]
We are entering a new era where people are increasingly affordably equipped with more electronic gadgets. Electronics have become essential to our lives. For example, the average consumer now owns ...[Details]
Capable of providing precise and efficient thermal management for artificial intelligence computing power, intelligent sensing and autonomous driving systems
Shenzhen, ...[Details]
White light LEDs are voltage-sensitive devices. In actual operation, their upper limit is 20mA. However, the current often increases due to various reasons during use. If no protective measures are...[Details]
The Automotive Testing and Quality Assurance Expo (ATE 2025) will open on August 27th. At the expo, Rohde & Schwarz (R&S) will showcase six automotive testing solutions, themed "Intelligently Drivi...[Details]
Recently, South Korean robotics giant WIRobotics launched its first general-purpose humanoid robot, ALLEX, at the Robotics Innovation Center (RIH) at the Korea University of Science and Technology....[Details]
When discussing autonomous driving technology, there are often two extremes: on the one hand, there's the vision of "fully autonomous driving," while on the other, there's concern about potential s...[Details]
Overview
As handheld voice communication devices become more and more popular, they are increasingly used in noisy environments, such as airports, busy roads, crowded bars, etc. In such noisy ...[Details]
Intel®
Xeon®
6
-
core processors now support the new Amazon EC2 R8i and R8i-flex instances on Amazon Web Services (AWS).
These new instances offer superior performance and fast...[Details]
Preface
Low-voltage motors are widely used in nonferrous metallurgical plants. Their abnormal operation not only impacts normal production but can also threaten human life. Therefore, providin...[Details]
With the increasing popularity of automated equipment, linear modules, a common auxiliary device for automated equipment, have also seen a bright future. In particular, in recent years, many small ...[Details]
There are many motors that can use thyristor speed control, and they can be used in almost all industries. Various types of motors, such as fans, pumps, AC motors, DC motors, torque motors, single-...[Details]