EEWORLDEEWORLDEEWORLD

Part Number

Search

86010C-E-26SE

Description
MIL Series Connector, 26 Contact(s), Metal, Female, Crimp Terminal, Receptacle
CategoryThe connector    The connector   
File Size65KB,1 Pages
ManufacturerHiRel Connectors Inc
Websitehttps://hirelco.net
Download Datasheet Parametric View All

86010C-E-26SE Overview

MIL Series Connector, 26 Contact(s), Metal, Female, Crimp Terminal, Receptacle

86010C-E-26SE Parametric

Parameter NameAttribute value
MakerHiRel Connectors Inc
Reach Compliance Codeunknown
Other featuresSTANDARD: MIL-DTL-38999
Back shell typeSOLID
Body/casing typeRECEPTACLE
Connector typeMIL SERIES CONNECTOR
Contact to complete cooperationNOT SPECIFIED
Contact point genderFEMALE
Coupling typeTHREADED
DIN complianceNO
empty shellNO
Environmental characteristicsCORROSION RESISTANT; ENVIRONMENT RESISTANT; FLUID RESISTANT
Filter functionNO
IEC complianceNO
MIL complianceYES
Manufacturer's serial number86010
Plug informationMULTIPLE MATING PARTS AVAILABLE
Mixed contactsNO
Installation typeCABLE AND PANEL
OptionsGENERAL PURPOSE
Shell materialMETAL
Housing sizeE
Termination typeCRIMP
Total number of contacts26
D38999/24
Jam Nut Mount Environment Resistant Receptacle
MIL-DTL-38999
Series III – Threaded Coupling
NOTES:
1. PANEL THICKNESS .126/.050 [3.20/1.58]
2. CONNECTOR CONTAINS REQUIRED FEATURES FOR
PROPER FIT IN A TYPE "E" PANEL
3. FOR CONNECTOR COMPONENTS AND ACCESSOROES,
SEE PAGE C-5
ØA
2 PLCS
1.279 [32.5]
MAX
.889 [22.6] MAX.
.519/.500 [13.2/12.7]
(FULLY MATED INDICATOR
BAND - RED)
S
P
SEE CONTACT
STYLE
DESIGNATOR
ON ORDERING
INFORMATION
PAGE
B Flat
BB Thd
G Thd
O-Ring
W
VV Thd
SHELL SHELL
SIZE
SIZE CODE
9
11
13
15
17
19
21
23
25
A
B
C
D
E
F
G
H
J
ØA
±.011
[±0.3]
1.189 [30.2]
1.374 [34.9]
1.500 [38.1]
B Flat BB Thd G Thd
CLASS 2A
+.004/-.006
[+0.10/-0.15] 0.1P-0.3L-TS
.651 [16.53]
.751 [19.07]
.938 [23.82]
.6250
.7500
.8750
1.0000
1.1875
1.2500
1.3750
1.5000
1.6250
M17 x 1.0
M20 x 1.0
M25 x 1.0
M28 x 1.0
*M32 x 1.0
M35 x 1.0
M38 x 1.0
M41 x 1.0
M44 x 1.0
P
S
±.016
[±0.4]
VV Thd
-6g 0.100R
M12 x 1.0
M15 x 1.0
M18 x 1.0
M22 x 1.0
M25 x 1.0
M28 x 1.0
M31 x 1.0
M34 x 1.0
M37 x 1.0
W
+.035/-.004
[+0.9/-0.1]
.087 [2.2]
.087 [2.2]
.087 [2.2]
.087 [2.2]
.087 [2.2]
.118 [3.0]
.118 [3.0]
.118 [3.0]
.118 [3.0]
-6g 0.100R +.024/-.000
[+0.6/-0.0]
.555 [14.1] 1.063 [27.0]
.555 [14.1] 1.252 [31.8]
.555 [14.1] 1.374 [34.9]
.555 [14.1] 1.500 [38.1]
.555 [14.1] 1.626 [41.3]
.555 [14.1] 1.811 [46.0]
.555 [14.1] 1.937 [49.2]
.555 [14.1] 2.063 [52.4]
.555 [14.1] 2.189 [55.6]
1.626 [41.3] 1.062 [26.97]
1.752 [44.5] 1.187 [30.15]
1.937 [49.2] 1.312 [33.32]
2.063 [52.4] 1.437 [36.50]
2.189 [55.6] 1.562 [39.67]
2.311 [58.7] 1.687 [42.85]
* = MODIFIED MAJOR DIA. 1.258/1.252 [31.95/31.80]
DIMENSIONS ARE IN INCHES [MILLIMETERS]
United States
– 760 W. Wharton Drive, Claremont CA. 91711
Ph: 909-626-1820
FAX: 909-399-0626
Web:
www.HIRELCO.com
Europe
– 5 Rue Des Longues Raies, Z.I. Des Garennes, 78440; Gargenville, France
Ph: 33(0) 1-309-38999 or U.K. 44(0)1-980-843887
FAX 33(0) 1-309-38913
Web:
www.HIRELCO.com
C-16
I want to know the displacement sensor selection (effective measurement range 512mm), it is too difficult to choose
The requirement for selecting a sensor is that the measuring range must be at least greater than 512MM, the error must be within 1mm for every 32mm movement, and the total error must be within 6mm for...
崔一 Sensor
Biosensor technology cares for "vulnerable groups" and is expected to be used for in-vehicle monitoring
Exmovere Ltd. has announced the launch of a web-based biosensor watch service that meets the medical monitoring needs of the elderly.The Exmocare watch can monitor pulse, heart rate variability and sk...
frozenviolet Automotive Electronics
EVB connects to *.cdb database?
Private Sub Command1_Click() Dim cnMobileSales As ADOCE.Connection Dim strPath As String Dim rs As ADOCE.Recordset Set cnMobileSales = CreateObject("ADOCE.Connection.3.0") Set rs = CreateObject("ADOCE...
hsd325 Embedded System
School has started~ The beasts are back in the cage~~ The sound of reading is so nice~
School has started, my little beast has gone to school~ There is a school behind my community. Today, I was so happy to hear the students reading and playing~~~Learning is really fun~~Learning makes m...
okhxyyo Talking
Comparison Unit
Can I ask which timer of the EV comparison unit can be set? In which register should I set it? I looked at an example and it seems that there is no setting option for the register involved. So what is...
bsfbaby713 Analogue and Mixed Signal
Urgent! I need to design a keyboard LED indicator based on a single-chip computer using C language! Attached is the circuit diagram! Please help!
The program for the 7*6 matrix keyboard has been compiled. Each key value is stored in an array such as key[7][6]. Now there is a 7*5 matrix keyboard LED indicator. How to make the corresponding indic...
staring321 MCU

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1849  2896  1725  228  1621  38  59  35  5  33 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号