IP117MAHVE
IP117MHVE
IP117MAE
IP117MEA
1.27 (0.050)
1.07 (0.040)
9.14 (0.360)
8.64 (0.340)
12 13 14 15 16
1.39 (0.055)
1.02 (0.040)
≈
2.16 (0.085)
0.5 AMP
POSITIVE ADJUSTABLE
VOLTAGE REGULATOR
IN CERAMIC SURFACE
MOUNT PACKAGE
FEATURES
• OUTPUT VOLTAGE RANGE ADJUSTABLE:
1.25 TO 40V FOR STANDARD VERSION
1.25 TO 60V FOR –HV VERSION
• 1% OUTPUT VOLTAGE TOLERANCE
(–A VERSIONS)
• 0.3% LOAD REGULATION
• 0.01% / V LINE REGULATION
• COMPLETE SERIES OF PROTECTIONS:
• CURRENT LIMITING
• THERMAL SHUTDOWN
• SOA CONTROL
11
7.62 (0.300)
7.12 (0.280)
17
18
1
2
0.76 (0.030)
0.51 (0.020)
10
9
8
7
6
5
4
3
1.65 (0.065)
1.40 (0.055)
0.33 (0.013)
Rad.
0.08 (0.003)
1.39 (0.055)
1.15 (0.045)
0.43 (0.017)
0.18 (0.007 Rad.
Pins 4,5
– Adjust
Pins 6,7,8,9,10,11,12,13 – V
IN
Pins 15,16,17,18,1,2
– V
OUT
DESCRIPTION
The IP117M Series are three terminal positive adjustable voltage regulators capable of supplying in excess of 0.5A over a
1.25V to 60V output range. These regulators are exceptionally easy to use and require only two external resistors to set the
output voltage. In addition to improved line and load regulation, a major feature of the “A” series is the initial output voltage
tolerance, which is guaranteed to be less than 1%.
Over full operating conditions, including load, line, and power dissipation, the reference voltage is guaranteed not to vary more
than 2%. These devices exhibit current limit, thermal overload protection, and improved power device safe operating area
protection, making them essentially indestructible.
ABSOLUTE MAXIMUM RATINGS
(T
case
= 25°C unless otherwise stated)
V
I–O
P
D
T
J
T
STG
Input - Output Differential Voltage
Power Dissipation
Operating Junction Temperature Range
Storage Temperature
– Standard
– HV Series
40V
60V
Internally limited
–55 to 150°C
–65 to 150°C
Semelab Plc reserves the right to change test conditions, parameter limits and package dimensions without notice. Information furnished by Semelab is believed
to be both accurate and reliable at the time of going to press. However Semelab assumes no responsibility for any errors or omissions discovered in its use.
Semelab encourages customers to verify that datasheets are current before placing orders.
Semelab plc.
Telephone +44(0)1455 556565. Fax +44(0)1455 552612.
E-mail:
sales@semelab.co.uk
Website:
http://www.semelab.co.uk
Document Number 5383
Issue 1
IP117MAHVE
IP117MHVE
IP117MAE
IP117MEA
Parameter
V
REF
Reference Voltage
Test Conditions
I
OUT
= 10mA
I
OUT
= 10mA to I
MAX
V
IN
– V
OUT
= 3V to V
MAX
P
≤
P
MAX
T
J
= –55 to +150°C
IP117MAHV
IP117MA
Min.
Typ.
Max.
1.238
1.220
1.25
1.250
0.005
0.010
5
0.1
15
0.3
0.002
C
ADJ
= 0
C
ADJ
= 10μF
65
66
80
50
0.2
100
5
V
OUT
≤
5V
V
OUT
≥
5V
V
OUT
≤
5V
V
OUT
≥
5V
1.262
1.270
0.010
0.020
15
0.3
50
1
0.020
IP117MHV , IP117M
Min.
Typ.
Max.
Units
V
1.200
1.250
0.010
0.020
5
0.1
20
0.3
0.030
65
66
80
50
0.2
100
5
1.300
0.020
0.050
15
0.3
50
1
0.070
V
ΔV
OUT
ΔV
IN
ΔV
OUT
ΔI
OUT
Line Regulation
1
V
IN
– V
OUT
= 3V to V
MAX
T
J
= –55 to +150°C
I
OUT
= 10mA to I
MAX
%/V
mV
%
mV
%
%/W
dB
dB
μA
μA
Load Regulation
1
I
OUT
= 10mA to I
MAX
T
J
= –55 to +150°C
t
p
= 20ms
V
OUT
= 10V
f = 120Hz
Thermal Regulation
Ripple Rejection
I
ADJ
ΔI
ADJ
Adjust Pin Current
Adjust Pin Current
Change
T
J
= –55 to +150°C
T
J
= –55 to +150°C
I
OUT
= 10mA to I
MAX
T
J
= –55 to +150°C
V
IN
– V
OUT
= 2.5V to V
MAX
V
IN
– V
OUT
= 40V
T
J
= –55 to +150°C
V
IN
– V
OUT
= 60V
(HV SERIES)
T
J
= –55 to +150°C
V
IN
– V
OUT
≤
15V
T
J
= –55 to +150°C
V
IN
– V
OUT
= 40V
V
IN
– V
OUT
= 60V
(HV SERIES)
0.50
0.15
I
MIN
Minimum Load
Current
3.5
3.5
0.80
0.20
0.30
1
t = 1000 Hrs
0.3
0.001
5
7
0.50
0.15
3.5
3.5
0.80
0.20
0.30
5
mA
7
A
A
%
1
%
%
13
°C/W
I
CL
Current Limit
ΔV
OUT
Temperature
ΔTEMP
Stability
ΔV
OUT
ΔTIME
e
n
R
θJC
Long Term Stability
RMS Output Noise
(% of V
OUT
)
Thermal Resistance
Junction to Case
T
J
= –55 to +150°C
T
A
= +125°C
f = 10 Hz to 10 kHz
LCC4 Package
2
1
1
0.3
0.001
13
1) Regulation is measured at constant junction temperature, using pulse testing at a low duty cycle. Changes in output voltage due to
heating effects are covered under thermal regulation specifications.
2) Test Conditions unless othewise stated:
V
IN
– V
OUT
= 5V , T
J
= 25°C , I
OUT
= 0.1A , P
MAX
= 10W , I
MAX
= 0.5A
V
MAX
= 40V for standard series , 60V for HV series.
Semelab Plc reserves the right to change test conditions, parameter limits and package dimensions without notice. Information furnished by Semelab is believed
to be both accurate and reliable at the time of going to press. However Semelab assumes no responsibility for any errors or omissions discovered in its use.
Semelab encourages customers to verify that datasheets are current before placing orders.
Semelab plc.
Telephone +44(0)1455 556565. Fax +44(0)1455 552612.
E-mail:
sales@semelab.co.uk
Website:
http://www.semelab.co.uk
Document Number 5383
Issue 1