EEWORLDEEWORLDEEWORLD

Part Number

Search

3EDK1

Description
120 V, 50/60 HZ, SINGLE PHASE EMI FILTER
CategoryPassive components   
File Size178KB,3 Pages
ManufacturerMACOM
Websitehttp://www.macom.com
Download Datasheet Parametric View All

3EDK1 Online Shopping

Suppliers Part Number Price MOQ In stock  
3EDK1 - - View Buy Now

3EDK1 Overview

120 V, 50/60 HZ, SINGLE PHASE EMI FILTER

3EDK1 Parametric

Parameter NameAttribute value
working frequency50/60 HZ
stateACTIVE
Installation typePANEL MOUNT
DimensionsL85.1XB52.6XH29.5 (mm)/L3.35XB2.07XH1.16 (inch)
Manufacturer SeriesDK
high capacity2250 V
filter typeSINGLE PHASE EMI FILTER
Rated current6 A
Rated voltage120 V
Maximum leakage current0.2200 mA
Maximum insertion loss frequency46 dB
Minimum insertion loss frequency10 dB
Corcom Product Guide
Catalog: 1654001
Issue Date: 06.2011
Enhanced Differential Mode Performance K Series RFI Line Filters
DK Series
DK3
UL Recognized
CSA Certified
VDE Approved
DK1
DK6
DK Series
• Higher performance Line to Line attenuation than
the K Series
• E version meets the low leakage current
requirements of VDE portable equipment
and non-patient care equipment
• V version features same high performance
with more cost-effective design
Specifications
Maximum leakage current each Line to Ground:
VDK Models
EDK Models
@ 120 VAC 60 Hz:
@250 VAC 50 Hz:
Hipot rating (one minute):
Line to Ground:
Line to Line:
Rated Voltage (max):
.4 mA
.7 mA
.22 mA
.38 mA
2250 VDC
1450 VDC
250 VAC
50/60 Hz
1 to 20A
Ordering Information
10 E DK 3
Input / Output Style
1 – .250 [6.3] spade terminals
3 – Wire leads
6 – Threaded bolt
DK Series
Leakage current designation
E – Low leakage
(<0.5 mA)
V – Standard
Current Rating
1, 3, 6, 10, or 20A
Operating Frequency:
Rated Current:
Operating Ambient Temperature Range
(at rated current Ir):
-10°C to +40°C
In an ambient temperature (Ta) higher than +40°C
the maximum operating current (Io) is calculated as
follows: Io = Ir
(85-Ta)/45
Available Part Numbers
1VDK1
1VDK3
3VDK1
3VDK3
6VDK1
6VDK3
10VDK1
10VDK3
20VDK1
20VDK6
1EDK1
1EDK3
3EDK1
3EDK3
6EDK1
6EDK3
10EDK1
10EDK3
20EDK1
Electrical Schematic
LINE
LOAD
18
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
For email, phone or live chat, please go to
te.com/help
corcom.com
What is the difference between the address field and the endpoint field (ENDP) in USB?
What is the difference between the address field and the endpoint field (ENDP) in USB? The address field has 7 bits, which means it supports 127 devices, but the endpoint field has only 4 bits, which ...
debugme Embedded System
What measures should be taken to prevent inrush current behind a rectifier circuit?
As the title says, I'm looking at a power supply recently. The filter capacitor after the power rectifier bridge is 450V. After the power is turned on, the current passing through the rectifier bridge...
charlin Embedded System
Please recommend a power supply
Input: 380V AC Output: 12V DC Is there any mature module? Please recommend a 380V two-phase transformer to low voltage, and then rectify it to 12V. I don't care about this detail. It would be better i...
ywlzh Integrated technical exchanges
Talking about youth with ideals and reality
Hide your ideals first, you don't have to think about them every day. Because you can't afford a house, love is too expensive; interpersonal relationships are too difficult, and you dare not say no; t...
苏莎莎 Talking
[The boards that accompanied me through the years] One board, one story!!!
[i=s]This post was last edited by youki12345 on 2015-2-19 18:49[/i] I saw many friends in the forum showing off their own boards. They are all electronics geeks. I don’t have much, but I’ll show it of...
youki12345 Talking
Problems with controlled 24V and controlled 0V
Design a machine to control the air supply through a safety relay I would like to ask, is it better to control 24V or 0V? It seems that 0V control is rarely used in China....
eeleader-mcu Industrial Control Electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2182  1467  2156  2033  2213  44  30  41  45  56 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号