EEWORLDEEWORLDEEWORLD

Part Number

Search

800-011-07MT10-200AY

Description
Circular Connector, 13 Contact(s), Aluminum Alloy, Male, Crimp Terminal, Receptacle, ROHS COMPLIANT
CategoryThe connector    The connector   
File Size238KB,4 Pages
ManufacturerGlenair
Websitehttp://www.glenair.com/
Environmental Compliance
Download Datasheet Parametric View All

800-011-07MT10-200AY Overview

Circular Connector, 13 Contact(s), Aluminum Alloy, Male, Crimp Terminal, Receptacle, ROHS COMPLIANT

800-011-07MT10-200AY Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
MakerGlenair
package instructionROHS COMPLIANT
Reach Compliance Codecompliant
Other featuresPOLARIZED
Back shell typeSOLID
Body/casing typeRECEPTACLE
Connector typeCIRCULAR CONNECTOR
Contact to complete cooperationGOLD (50) OVER NICKEL (50)
Contact completed and terminatedGold (Au) - with Nickel (Ni) barrier
Contact point genderMALE
Contact materialCOPPER ALLOY
Coupling typeTHREADED
DIN complianceNO
empty shellYES
Filter functionNO
IEC complianceNO
JESD-609 codee4
MIL complianceNO
Mixed contactsYES
Installation typeCABLE AND PANEL
OptionsGENERAL PURPOSE
Shell surfaceNICKEL PLATED
Shell materialALUMINUM ALLOY
Housing size10
Termination typeCRIMP
Total number of contacts13
A
B
C
D
E
F
In-Line
G
H
J
K
L
M
© 2009 Glenair, Inc.
Series 800
Series 800 “Mighty Mouse” with UN Mating Thread
Crimp Receptacle Ordering Information
800-010 and 800-011
In-Line
Rear Panel Jam Nut Mount
Square Flange Mount
Integral Band Platform
for direct attachment of a cable
Three Shell Options:
Jam nut with o-ring for rear panel
shield using a
BAND-IT®
strap. Install a boot, or overmold
mounting, square
ange or in-line receptacle for free-hanging
onto the band platform. An accessory thread is available
cables.
for attaching strain reliefs and backshells.
HOW TO ORDER
Sample Part Number
80 0- 0 11
Series
-0 1
Shell Style
M
Shell Material / Finish
C
6-4
Shell Size- Insert
Arrangement
No. of Contacts
Arr.
P
Contact Type
Connector supplied
with contacts
Pin
Socket
Connector supplied
without contacts
Pin
Socket Connector
Connectors with contacts
are supplied with signal
and/or power crimp
contacts. These contacts
are not installed.
Coaxial contacts and non-
standard signal contacts
are ordered separately.
N
Shell Key
Position
N
Normal
-01
Aluminum / Black Anodize
(Non-Conductive)
RoHS Compliant
Aluminum / Electroless
Nickel
RoHS Compliant
Receptacle with
Banding Platform
800-010
M
-02
Receptacle with
Accessory Thread
800-011
Square Flange
for Front or Rear
ZN
Mounting
Aluminum / Zinc-Nickel with
Olive Drab Chromate
Aluminum / Zinc-Cobalt with
Black Chromate
RoHS Compliant
Aluminum / Cadmium with
Olive Drab Chromate
NF
UCR
-07
Jam Nut for Rear
ZNU
Panel Mounting Aluminum / Zinc-Nickel with
Black Chromate
Aluminum / Nickel-PTFE
RoHS Compliant
Stainless Steel / Passivated
RoHS Compliant
MT
Z1
5-3
6-1
6-4
6-7
7-1
7-10
8-2
8-13
8-200
9-4
9-19
9-200
9-201
10-5
10-26
10-200
10-201
10-202
12-2
12-3
12-7
12-37
12-200
12-201
#23 #20 #16 #12
3
1
4
7
1
10
2
13
4
19
4
8
26
12
4
8
1
2
2
2
3
7
37
6
10
2
2
2
5
2
4
2
P
S
X
Pos. X
Y
Pos. Y
A
B
Z
Pos. Z
Dimensions in inches (millimeters) and are subject to change without notice.
CAGE Code 06324
Printed in U.S.A.
GLENAIR, INC. • 1211 AIR WAY • GLENDALE, CA 91201-2497 • 818-247-6000 • FAX 818-500-9912
www.glenair.com
C-6
Rev. 01-FEB-2009
E-Mail: sales@glenair.com
The rewards of life are far away at the end of the journey [Transfer]
How did people discover the transparency and purity of wine from the whiteness of rice, the redness of sorghum, and the purpleness of grapes?   The legend goes that two people had an encounter with a ...
huixun001 Talking
【Signal Processing】FPGA Software Radio Related Articles
Previous post: https://bbs.eeworld.com.cn/thread-312807-1-2.html[[i] This post was last edited by ssawee on 2011-12-19 22:47 [/i]]...
ssawee FPGA/CPLD
What do you think about the application of IT in robots?
How can IT be used in the robotics industry, especially in deep learning?...
szsanhang TI Technology Forum
Wireless data acquisition, environmental monitoring, gas monitoring, remote temperature and humidity monitoring, chemical environmental monitoring solutions
Environmental monitoring, gas monitoring, temperature and humidity monitoring, chemical environmental monitoring solutionsProject BackgroundWhile the economy is developing rapidly, it has also caused ...
zongkezhikong Energy Infrastructure?
LM3S8962 cannot be recognized when debugging with external J-LINK
I applied for TI's LM3S8962 development kit, but there is only a large board, no small board. I want to use an external J-LINK to debug the LM3S8962 development board, but under the RVMDK settings, th...
jeremy414560967 Microcontroller MCU
I would like to ask you for an assembly statement, thank you! Waiting online
[i=s] This post was last edited by dontium on 2015-1-23 13:38 [/i] I use 2812 and have been writing programs in C language. Recently, I need to make a digital filtering program, so I need to write it ...
christina.feng Analogue and Mixed Signal

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 95  1698  1351  2509  2831  2  35  28  51  57 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号