EEWORLDEEWORLDEEWORLD

Part Number

Search

KB15SKW01-05-A

Description
0.4VA maximum 28V AC/DC maximum (Applicable Range 0.1mA ~ 0.1A 20mV ~ 28V)
File Size447KB,13 Pages
ManufacturerNKK
Websitehttps://www.nkkswitches.com.cn
Download Datasheet View All

KB15SKW01-05-A Overview

0.4VA maximum 28V AC/DC maximum (Applicable Range 0.1mA ~ 0.1A 20mV ~ 28V)

Series KB
Toggles
Miniature Pushbuttons
General
Specifications
Electrical Capacity (Resistive Load)
Power Level (silver):
Logic Level (gold):
1A @ 125/250V AC or 1A @ 30V DC
0.4VA maximum @ 28V AC/DC maximum (Applicable Range 0.1mA ~ 0.1A @ 20mV ~ 28V)
Note: Find additional explanation of operating range in Supplement section.
Pushbuttons
Rockers
Other Ratings
Programmable
Illuminated PB
D
Contact Resistance:
Insulation Resistance:
Dielectric Strength:
Mechanical Life:
Electrical Life:
Nominal Operating Force:
Contact Timing:
Travel:
Keylocks
50 milliohms maximum
1,000 megohms minimum @ 500V DC
For Silver: 1,000V AC minimum between contacts for 1 minute minimum &
1,500V AC minimum between contacts & case for 1 minute minimum;
For Gold: 750V AC minimum between contacts for 1 minute minimum &
1,500V AC minimum between contacts & case for 1 minute minimum
100,000 operations minimum
50,000 operations minimum for silver; 100,000 operations minimum for gold
Single pole 0.98 ~ 2.45N for maintained & 0.98 ~ 1.96N for momentary;
Double pole 1.47 ~ 3.43N for maintained & 1.47 ~ 2.94N for momentary
Nonshorting (break-before-make)
Pretravel .087” (2.2mm); Overtravel .031” (0.8mm); Total Travel .118” (3.0mm)
Materials & Finishes
Slides
Housing:
Movable Contactor:
Stationary Contacts:
Housing Base:
Terminal Base:
Common Terminals:
End Terminals:
Lamp Terminals:
Polyamide (UL94V-0)
Silver for power circuit; copper with gold plating for logic level circuit
Silver for power circuit; copper with gold plating for logic level circuit
Polyamide (UL94V-0)
Polyester
Phosphor bronze with silver flash plating for power circuit;
Phosphor bronze with gold flash plating for logic level circuit
Brass with silver flash plating for power circuit;
Brass with gold flash plating for logic level circuit
Phosphor bronze with nickel flash plating
Tactiles
Rotaries
Environmental Data
Operating Temperature Range:
Humidity:
Vibration:
Shock:
–25°C through +50°C (–13°F through +122°F) for Illuminated
–25°C through +70°C (–13°F through +158°F) for Nonilluminated
90 ~ 95% humidity for 96 hours @ 40°C (104°F)
10 ~ 55Hz with peak-to-peak amplitude of 1.5mm traversing the frequency range & returning
in 1 minute; 3 right angled directions for 2 hours
50G (490m/s
2
) acceleration (tested in 6 right angled directions, with 3 shocks in each direction)
Touch
Tilt
Installation
Indicators
Mounting Torque:
Cap Installation Force:
Soldering Time & Temperature:
0.78Nm (6.9 lb
in) maximum
4.51N (1.0 lbf) maximum downward force on cap
Manual Soldering: See Profile A in Supplement section.
Standards & Certifications
Accessories
Flammability Standards:
UL:
Supplement
CSA:
UL94V-0 housing & housing base
File No. E44145
Single & double pole models recognized at 1A @ 125/250V AC, 1A @ 30V DC, & 0.4VA @ 28V DC.
Add “/U” to end of part number to order UL mark on switch.
Add “/CUL” to end of part number to order cULus mark on switch.
File No. 023535_0_000
Single & double pole models recognized at 1A @ 125/250V AC, 1A @ 30V DC, & 0.4VA @ 28V DC.
Add “/C” to end of part number to order CSA mark on switch.
www.nkk.com
D22
Can the external interrupt program of mini2440 be experimented directly in RAM?
I want to verify the external interrupt triggered by a button in a bare metal program. Can I directly DOWN it in RAM to see the effect?...
ounie Embedded System
About WINCE network issues
Simply put, the NK.NB0 I compiled cannot obtain a normal address from the router. The addresses I finally get are all private addresses such as 169.254.*.*. If you set a static IP, you cannot ping it....
heyuqi Embedded System
Have you ever received such a blessing text message?
[table][tr][td]It is said that this is the most popular blessing message for the Year of the Tiger. I wonder if it is popular with you? 1 A new year, a new beginning. New hope, new vitality. New oppor...
lixiaohai8211 Talking
Ask: Application of writing macro instructions
SYS(WRITE _WORDS,90) For example, if you want to write the data of @100 into %mw200 of PLC , what should the data of @90 to @96 be? I understand that @90=0; @91=200; @92=?; @93=?; @94=?; @95=100; @96=...
eeleader Industrial Control Electronics
What is the difference between LM4F232 and TM4C123?
What is the difference between LM4F232 and TM4C123? I have an official LM4F232 board. I want to use it to run the TM4C123 TI-RTOS example. Is it possible?...
gongjian32 Microcontroller MCU
PXA310's SPI controlled MCP2515 cannot read?
The SPI of PXA310 is used to control MCP2515, and the transmission is normal. After writing the command word to 2515, the chip status register is read. The MISO pin signal is normal when observed by o...
huangruihua Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2534  428  2602  2476  524  52  9  53  50  11 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号