450W/650W/1000W Modular Power
Features :
MP
Various output configuration is selectable
Built in active PFC, PF>0.95
Universal AC input/ full range
Remote Control on every individual output module
series
ZVT technology to reduce power dissipation and improve efficiency
Remote Sense on every individual output module(MS-75,150,300)
Built in parallel function(MS-300)
Protections: Short circuit / Overload / Over voltage for all output modules
Additional 12V/0.1A auxiliary output for remote control
Cooling by built-in DC fan with fan alarm function
3 years warranty
Output Configuration Guide
MP
-
SLOT1 SLOT2 SLOT3 SLOT4 SLOT5 SLOT6 SLOT7
450/650/1K0(450W/650W/1000W)
Modular Power with PFC
450W/650W(5SLOT)
Parallel or option code
(See Table 1.)
1000W(7SLOT)
-
Single output(MS-150)
1 SLOT (150W max.)
Voltage code
A
B
C
D
E
F
G
H
I
J
K
Voltage
2V
3.3V
5V
7.5V
12V
15V
18V
24V
27V
33V
48V
Single output(MS-300)
2 SLOT (300W max.)
Voltage code
2A
2B
2C
2D
2E
2F
2G
2H
2I
2J
2K
Voltage
2V
3.3V
5V
7.5V
12V
15V
18V
24V
27V
33V
48V
Single output(MS-75)
1 SLOT (75W max.)
Voltage code
L
M
N
O
P
Q
Voltage
3.3V
5V
12V
15V
24V
48V
Dual output(MD-100)
1 SLOT (100W max.)
Voltage code
R
S
T
U
V
W
X
Voltage
5V
5V
5V
12V
5V
15V
24V
5V
24V
12V
12V
12V
15V
15V
Example: MP1K0- A
SLOT1
O/P:2V@25A
2
E
#
S
2
K
SLOT2,3
O/P:12V@25A
SLOT4
Blank Slot
SLOT5
O/P:5V@10A
12V@4.2A
SLOT6,7
O/P:48V@6.3A
SPECIFICATION
MODEL
VOLTAGE RANGE
FREQUENCY RANGE
POWER FACTOR
INPUT
EFFICIENCY
AC CURRENT
INRUSH CURRENT
LEAKAGE CURRENT
OUTPUT
PROTECTION
TOTAL OUTPUT POWER
OVER TEMPERATURE
FAN ALARM
FUNCTION
REMOTE CONTROL
AUXILIARY POWER(AUX)
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
SAFETY &
EMC
(Note 5)
PFC-450
85 ~ 264VAC
47 ~ 63Hz
PF>0.95/230VAC
Note.1
83% typ.
PFC-650
120 ~370VDC
PF>0.98/115VAC at full load
84% typ.
3.2A/230VAC
9A/115VAC
30A/115VAC
4.5A/230VAC
50A/230VAC
PFC-1000
84% typ.
13.5A/115VAC
20A/115VAC
1000W max.
6.7A/230VAC
40A/230VAC
6.3A/115VAC
25A/115VAC
40A/230VAC
<1.5mA/240VAC
650W max.
450W max.
Thermal switch detect on the heatsink of power MOSFET
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
Output shutdown when FAN is malfunction
RC+/RC-: 0 ~ 0.8V or Short, Power ON
RC+/RC-: 4 ~ 12V or Open, Power OFF
12V@0.1A(only for Remote ON/OFF Control)
-20 ~ +70 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
-40 ~ +85
, 10 ~ 95% RH
0.03%/ (0 ~ 50
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 approved
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
/ 70% RH
ISOLATION RESISTANCE
HARMONIC CURRENT
EMS IMMUNITY
DIMENSION
PACKING
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25
EMI CONDUCTION & RADIATION
Compliance to EN55022 (CISPR22) Class B
Compliance to EN61000-3-2,-3
OTHERS
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, EN61000-6-1, EN61204-3, light industry level, criteria A
254*127*63.5mm (L*W*H)
278*127*63.5mm (L*W*H)
278*177.8*63.5mm (L*W*H)
1.8Kg(typ.); 6pcs / 11.8Kg / 1.25CUFT
2.16Kg(typ.); 6pcs / 14Kg / 1.34CUFT
3Kg(typ.); 6pcs /19Kg / 1.74CUFT
File Name:MP-450,650,1K0-SPEC 2008-08-05
450W/650W/1000W Modular Power
SPECIFICATION
1 SLOT Single output (150W) MS-150
OUTPUT VOLTAGE CODE
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
PEAK LOAD
OUTPUT
(MS-150)
RATED POWER
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE
Note.3
LINE REGULATION
LOAD REGULATION
MS-150A
2V
25A
0 ~ 25A
Note.4
30A
MP
MS-150F
15V
10A
0 ~ 10A
11.5A
150W
MS-150G MS-150H MS-150I
18V
8.5A
0 ~ 8.5A
9.8A
153W
24V
6.5A
0 ~ 6.5A
7.5A
156W
27V
5.8A
0 ~ 5.8A
6.7A
156.6W
12V
13A
0 ~ 13A
15A
156W
33V
4.7A
series
MS-150B
3.3V
25A
0 ~ 25A
30A
82.5W
80mVp-p
2.0%
0.5%
1.0%
MS-150C MS-150D MS-150E
5V
25A
0 ~ 25A
30A
125W
80mVp-p
4 ~ 6V
2.0%
0.5%
1.0%
7.5V
18A
0 ~ 18A
20.7A
135W
6 ~ 9V
2.0%
0.5%
1.0%
MS-150J
MS-150K
48V
3.2A
0 ~ 3.2A
3.68A
153.6W
40 ~ 53V
1.0%
0.2%
0.5%
0 ~ 4.7A
5.4A
155.1W
30 ~ 40V
1.0%
0.2%
0.5%
50W
RIPPLE & NOISE (max.)
Note.2
50mVp-p
3.0%
0.5%
2.0%
100mVp-p 150mVp-p 150mVp-p 150mVp-p 150mVp-p 150mVp-p 250mVp-p 250mVp-p
9 ~ 13.2V 13.2 ~ 16.8V 16.8 ~ 20V 20 ~ 26.4V 25 ~ 31V
1.0%
0.3%
0.5%
1.0%
0.3%
0.5%
1.0%
0.3%
0.5%
1.0%
0.2%
0.5%
1.0%
0.2%
0.5%
1.6 ~ 2.6V 2.6 ~ 4V
SETUP, RISE, HOLD UP TIME
1500ms, 50ms, 20ms at full load
OVERLOAD
PROTECTION
OVER VOLTAGE
FUNCTION
REMOTE INHIBIT CONTROL
OUTPUT VOLTAGE CODE
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
PEAK LOAD
OUTPUT
(MS-300)
RATED POWER
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE
Note.3
LINE REGULATION
LOAD REGULATION
121 ~ 150% rated output power
116 ~ 150% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
2.7 ~ 4V
4.1 ~ 5V
6.1 ~ 7.5V 9.1 ~ 11.2V 13.3 ~ 18V 16.9 ~ 22V 20.1 ~ 26V 26.5 ~ 35V 31.1 ~ 39V 40.1 ~ 48V 53.1 ~ 60V
Protection type : Shut down o/p voltage, re-power on to recover
RC+/RC-: 0 ~ 0.8V or OPEN, POWER ON
RC+/RC-: 4 ~ 12V POWER OFF
MS-300-2A MS-300-2B MS-300-2C MS-300-2D MS-300-2E MS-300-2F MS-300-2G MS-300-2H MS-300-2I
2V
50A
0 ~ 50A
Note.4
57.5A
2 SLOT Single output (300W) MS-300
MS-300-2J MS-300-2K
33V
9.1A
0 ~ 9.1A
10.5A
300.3W
30 ~ 40V
1.0%
0.2%
1.0%
48V
6.3A
0 ~ 6.3A
7.2A
302.4W
40 ~ 53V
1.0%
0.2%
1.0%
3.3V
50A
0 ~ 50A
57.5A
165W
80mVp-p
2.0%
0.5%
1.0%
5V
50A
0 ~ 50A
57.5A
250W
80mVp-p
4 ~ 6V
2.0%
0.5%
1.0%
7.5V
40A
0 ~ 40A
46A
300W
6 ~ 9V
2.0%
0.5%
1.0%
12V
25A
0 ~ 25A
29A
300W
15V
20A
0 ~ 20A
23A
300W
18V
16.7A
19.2A
300.6W
24V
12.5A
14.4A
300W
27V
11.2A
12.9A
302.4W
0 ~ 16.7A 0 ~ 12.5A 0 ~ 11.2A
100W
RIPPLE & NOISE (max.)
Note.2
80mVp-p
3.0%
0.5%
2.0%
100mVp-p 150mVp-p 150mVp-p 150mVp-p 150mVp-p 200mVp-p 250mVp-p 300mVp-p
9 ~ 13.2V 13.2 ~ 16.8V 16.8 ~ 20V 20 ~ 26.4V 25 ~ 31V
1.0%
0.3%
0.5%
1.0%
0.3%
0.5%
1.0%
0.3%
0.5%
1.0%
0.2%
1.0%
1.0%
0.2%
1.0%
1.6 ~ 2.6V 2.6 ~ 4V
PROTECTION
SETUP, RISE, HOLD UP TIME
1500ms, 50ms, 20ms at full load
116 ~ 150% rated output power
OVERLOAD
Protection type : Constant current limiting, recovers automatically after fault condition is removed
OVER VOLTAGE
3 ~ 4V
4.1 ~ 5V
6.1 ~ 7.5V 9.1 ~ 11.2V 13.3 ~ 18V 16.9 ~ 22V 20.1 ~ 26V 26.5 ~ 35V 31.1 ~ 39V 40.1 ~ 48V 53.1 ~ 60V
RC+/RC-: 4 ~ 12V POWER OFF
MS-75N
12V
6.3A
0 ~ 6.3A
7.3A
75.6W
150mVp-p
9 ~ 13.2V
1.0%
0.3%
0.5%
MS-75O
15V
5A
0 ~ 5A
5.8A
75W
150mVp-p
13.2 ~ 16.8V
1.0%
0.3%
0.5%
MS-75P
24V
3.2A
0 ~ 3.2A
3.7A
76.8W
150mVp-p
20 ~ 26.4V
1.0%
0.2%
0.5%
MS-75Q
48V
1.6A
0 ~ 1.6A
1.8A
76.8W
250mVp-p
40 ~ 53V
1.0%
0.2%
0.5%
Protection type : Shut down o/p voltage, re-power on to recover
RC+/RC-: 0 ~ 0.8V or OPEN, POWER ON
MS-75L
3.3V
15A
0 ~ 15A
Note.4
17.3A
FUNCTION
REMOTE INHIBIT CONTROL
OUTPUT VOLTAGE CODE
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
PEAK LOAD
1 SLOT Single output (75W) MS-75
MS-75M
5V
15A
0 ~ 15A
17.3A
75W
80mVp-p
4 ~ 6V
2.0%
0.5%
1.0%
OUTPUT
(MS-75)
RATED POWER
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE
Note.3
LINE REGULATION
LOAD REGULATION
49.5W
2.6 ~ 4V
2.0%
0.5%
1.0%
RIPPLE & NOISE (max.)
Note.2
80mVp-p
SETUP, RISE, HOLD UP TIME
1500ms, 50ms, 20ms at full load
OVERLOAD
PROTECTION
OVER VOLTAGE
FUNCTION
REMOTE INHIBIT CONTROL
116 ~ 150% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
4.1 ~ 5V
6.1 ~ 7.5V
13.3 ~ 18V
16.9 ~ 22V
26.5 ~ 35V
53.1 ~ 60V
Protection type : Shut down o/p voltage, re-power on to recover
RC+/RC-: 0 ~ 0.8V or OPEN, POWER ON
RC+/RC-: 4 ~ 12V POWER OFF
File Name:MP-450,650,1K0-SPEC 2008-08-05
450W/650W/1000W Modular Power
SPECIFICATION
1 SLOT Isolated Dual output (100W) MD-100
OUTPUT VOLTAGE CODE
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
OUTPUT
(MD-100)
RATED POWER
MD-100R
5V
10A
Note.6
90W
MP
MD-100U
15V
3.4A
24V
2.5A
100W
5V
8A
MD-100V
24V
2.5A
100.8W
12V
3.4A
MD-100W
12V
5A
100.8W
12V
3.4A
4A
series
MD-100S
5V
10A
100.4W
12V
4.2A
MD-100T
5V
10A
101W
MD-100X
15V
15V
2.7A
0 ~ 4.7A
5V
8A
2 ~ 10A 0 ~ 8A
2 ~ 10A 0 ~ 5.8A 2 ~ 10A 0 ~ 4.7A 0.5 ~ 3A 0 ~ 10A 0.6 ~ 3A 0 ~ 4.7A 1 ~ 5A 0 ~ 5.8A 1 ~ 4.7A
100.5W
RIPPLE & NOISE (max.)
Note.2
100mVp-p 100mVp-p 100mVp-p 150mVp-p 100mVp-p 150mVp-p 200mVp-p 100mVp-p 240mVp-p 120mVp-p 120mVp-p 120mVp-p 150mVp-p 150mVp-p
VOLTAGE ADJ. RANGE
4.75 ~ 5.5V 4.75 ~ 5.5V 4.75 ~ 5.5V 11.4 ~ 13.2V 4.75 ~ 5.5V 14.2 ~ 16.5V 22.8 ~ 26.4V 4.75 ~ 5.5V 22.8 ~ 26.4V 11.4 ~ 13.2V 11.4~ 13.2V 11.4~ 13.2V 14.2 ~ 16.5V 14.2 ~ 16.5V
VOLTAGE TOLERANCE
Note.3
3.0%
3.0%
3.0%
3.0%
3.0%
3.0%
3.0%
3.0%
3.0%
2.0%
3.0%
2.0%
3.0%
2.0%
LINE REGULATION
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
0.5%
1.0%
0.5%
1.0%
0.5%
LOAD REGULATION
2.0%
2.0%
2.0%
2.0%
2.0%
2.0%
2.0%
2.0%
2.0%
1.0%
2.0%
1.0%
2.0%
1.0%
SETUP, RISE, HOLD UP TIME
1500ms, 50ms, 20ms at full load
OVERLOAD
105 ~ 150% rated output power
Protection type : Shut down o/p voltage, re-power on to recover
5.6 ~ 7.2V 5.6 ~ 7.2V 5.6 ~ 7.2V 13.3 ~ 17V 5.6 ~ 7.2V 16.6 ~ 22V 26.5 ~ 34V 5.6 ~ 7.2V 26.5 ~ 34V 13.3 ~ 17V 13.3 ~ 17V 13.3 ~ 17V 16.6 ~ 22V
Protection type : Shut down o/p voltage, re-power on to recover
RC+/RC-: 0 ~ 0.8V or OPEN, POWER ON
RC+/RC-: 4 ~ 12V POWER OFF
16.6 ~ 22V
PROTECTION
OVER VOLTAGE
FUNCTION
NOTE
REMOTE INHIBIT CONTROL
1. MP450:The value changed by installing different output modules. The efficiency in specification means output modules are composed by following modules.
5V(Voltage code C)*1, 12V(Voltage code E)*1, 24V(Voltage code H)*1, 5V(Voltage code M)*1.
MP650:The value changed by installing different output modules. The efficiency in specification means output modules are composed by following modules.
5V(Voltage code C)*2, 12V(Voltage code E)*1, 24V(Voltage code H)*2.
MP1K0:The value changed by installing different output modules. The efficiency in specification means output modules are composed by following modules.
5V(Voltage code C)*2, 12V(Voltage code E)*2, 24V(Voltage code H)*3.
The hold-up time of above combination is 20ms(typ.)
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. 35% Duty cycle maximum within every 10 seconds. Average output power should not exceed the rated power.
5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
6. If the output voltage adjust to higher level, the rated current should be derated to meet the total rated power for both outputs(For MD-100 only).
Table 1. Parellel code(For MS-300 only)
Code
X
1
2
3
4
5
6
SLOT1
SLOT2
SLOT3
SLOT4
SLOT5
SLOT6
SLOT7
-----
-----
-----
-----
-----
-----
Code X,1,2 for MP450,MP650
Code X,1,2,3,4,5,6 for MP1K0
File Name:MP-450,650,1K0-SPEC 2008-08-05
450W/650W/1000W Modular Power
Mechanical Specification
MP
series
Unit:mm
MP450
12 max.
254
147.5
19
16 max.
12.5
8-M4(Both Sides)
147.5
19
12.25
1
2
3
CN4
4-M4
3
TB1
10
2
1
8.2
MP650
12 max.
278
171.5
19 16 max.
8-M4(Both Sides)
171.5
19
12.25
CN4
1
2
3
4-M4
Air flow
direction
3
TB1
10
2
1
8.2
File Name:MP-450,650,1K0-SPEC 2008-08-05
101.5
127
38
63.5
12.5
101.5
127
Air flow
direction
63.5
38
450W/650W/1000W Modular Power
Mechanical Specification
MP1K0
12 max.
278
171.5
MP
series
19
16 max.
12.5
8-M4(Both Sides)
171.5
CN4
1
2
3
19
15.65
4-M4
3
2
1
TB1
10
8.2
TB1(PFC-450/650/1K0)
Pin No.
1
2
3
Assignment
AC/L
AC/N
FG
CN4(PFC-450/650/1K0) : JST B3B-XH or equivalent
Assignment
Pin No.
1
+RC: +Remote ON/OFF
2
-RC: -Remote ON/OFF
3
VCC: 12V/0.1A auxiliary output
Mating Housing
JST XHP
or equivalent
Terminal
JST SXH-001T-P0.6
or equivalent
Mechanism of Output Modules
MS-75
138
16 max.
CN51
4
1
21 max.
152.4
3 max.
Air flow
direction
177.8
38
63.5
Unit:mm
Output Connector( CN51) : JST B4B-XH or equivalent
Pin No.
1
2
3
4
Assignment
+S: +Remote sensing
-S: -Remote sensing
+RC: +Remote ON/OFF
-RC: -Remote ON/OFF
Mating Housing
JST XHP
or equivalent
Terminal
JST SXH-001T-P0.6
or equivalent
60
-V
+V
SVR1
MS-150
138
16 max.
21 max.
3 max.
CN20
4
1
Output Connector( CN20) : JST B4B-XH or equivalent
Pin No.
1
2
3
4
Assignment
+S: +Remote sensing
-S: -Remote sensing
+RC: +Remote ON/OFF
-RC: -Remote ON/OFF
Mating Housing
JST XHP
or equivalent
Terminal
JST SXH-001T-P0.6
or equivalent
60
-V
+V
SVR2