EEWORLDEEWORLDEEWORLD

Part Number

Search

802-011-02Z17-10PA

Description
Circular Connector, 10 Contact(s), Stainless Steel, Male, Crimp Terminal, Receptacle,
CategoryThe connector    The connector   
File Size231KB,4 Pages
ManufacturerGlenair
Websitehttp://www.glenair.com/
Download Datasheet Parametric View All

802-011-02Z17-10PA Online Shopping

Suppliers Part Number Price MOQ In stock  
802-011-02Z17-10PA - - View Buy Now

802-011-02Z17-10PA Overview

Circular Connector, 10 Contact(s), Stainless Steel, Male, Crimp Terminal, Receptacle,

802-011-02Z17-10PA Parametric

Parameter NameAttribute value
MakerGlenair
Reach Compliance Codecompliant
Other featuresPOLARIZED
Back shell typeSOLID
Body/casing typeRECEPTACLE
Connector typeCIRCULAR CONNECTOR
Contact to complete cooperationNOT SPECIFIED
Contact point genderMALE
Coupling typeTHREADED
DIN complianceNO
empty shellNO
Environmental characteristicsENVIRONMENT RESISTANT
Filter functionNO
IEC complianceNO
MIL complianceNO
Plug informationMULTIPLE MATING PARTS AVAILABLE
Mixed contactsNO
Installation typeCABLE AND PANEL
OptionsGENERAL PURPOSE
Shell materialSTAINLESS STEEL
Housing size7
Termination typeCRIMP
Total number of contacts10
Series 802 “Aqua Mouse”
3500 PSI Rated
Series 802 Receptacles
A
Immersion Rated
to 3500 PSI. A
piston o-ring provides sealing to the
mating plug.
panel mounting, or in-line receptacles
for free-hanging cables.
Two Shell Styles:
Choose the
integral band platform for direct
attachment of a cable shield. Install
a boot, or overmold a boot over the
band platform. An accessory thread
is available for attaching strain reliefs
and backshells.
Jam Nut, Rear Mount
Nut
Moun
316 Series
Stainless Steel
shells
offer maximum resistance to
mechanical and environmental abuse.
Three Shell Mounting Options:
Jam nut with o-ring for rear panel
mounting, square flange for front
Square Flange
HOW TO ORDER SERIES 802 CRIMP RECEPTACLES
Sample Part Number
8 0 2- 0 11
Series
-02
Shell Style
ZM
Shell Material /
Finish
Z1
Stainless Steel /
Passivated
10 -26
Shell Size- Insert
Arrangement
5-3
6-1
6-4
6-7
7-1
7-10
8-13
9-4
9-19
10-26
12-2
12-37
14-55
15-85
3 #23 Contacts
1 #16 Contact
4 #23 Contacts
7 #23 Contacts
1 #12 Contact
10 #23 Contacts
13 #23 Contacts
4 #16 Contacts
19 #23 Contacts
26 #23 Contacts
2 #12 Contacts
37 #23 Contacts
55 #23 Contacts
85 #23 Contacts
P
Contact Type
B
Shell Key
Position
A
802-010
Receptacle with
Banding Platform
-01
In-Line
ZM
Stainless Steel /
Electroless Nickel
Plated
Standard #23 contacts
accept #22 through
#28 AWG wire. Use the
following contact codes
to specify these contacts:
Normal
B
Pos. B
P
Pin
C
Pos. C
S
Socket
Special contacts for
#26 to #30 AWG are
also available. Use the
following contact codes
to specify these contacts:
D
Pos. D
802-011
Receptacle with
Accessory Thread
-02
Square Flange
#23 contacts are packaged
with connectors. #16 and #12
contacts must be ordered
separately.
G
Pin
-07
Jam Nut for Rear
Panel Mounting
H
Socket
© 2007 Glenair, Inc.
CAGE Code 06324
Printed in U.S.A.
GLENAIR, INC. • 1211 AIR WAY • GLENDALE, CA 91201-2497 • 818-247-6000 • FAX 818-500-9912
www.glenair.com
E-5
Rev. 05-APR-2007
E-Mail: sales@glenair.com
Series 800
B
C
D
E
F
G
H
J
K
L
M
What impact can iDCS-Control technology have on industrial systems?
Designers of industrial systems often design one or two standardized devices to give their products specific functionality. For example, they might use one or two power integrated circuits (ICs) to op...
maylove Analogue and Mixed Signal
Detailed explanation of 50 classic circuit examples
Welcome to join 148124126, information will be updated at irregular intervals every day!...
不来客焖 PCB Design
Why do I feel that there is a problem with the SPI program in the msp430g2553 example? Please give me some advice
I am a beginner in SPI. I called the SPI program in the example and found that the value of UCA0RXBUF in the interrupt is always 0xff. The light only turns on when SLV_Data is also equal to 0xff. Why?...
dreamchaser09 Microcontroller MCU
Summary of Digital-Analog Circuits
Author: JimXiao9 Submitted: 2006-3-14 20:42:00Analog section   1. AC circuit with non-single parameter (5 points, one multiple-choice question and one long question)   Through the above two figures, I...
fighting Analog electronics
Let's talk about the analysis of inductor current
[size=5] The design of an inductor in a switching power supply presents many challenges to the engineer. The engineer must not only select the inductor value, but also consider the current that the in...
fish001 Analogue and Mixed Signal
Loopback test of cs8900a
I wonder if you guys have done a loopback test on cs8900a. My loopback hardware connection is: keep other lines unchanged, pull /test low, and connect txd+ to rxd+, txd- to rxd-. I wonder if there is ...
anliday Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1491  87  2405  1797  1530  31  2  49  37  50 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号