EEWORLDEEWORLDEEWORLD

Part Number

Search

803-013-AN8ZNU9-4NY-72

Description
Interconnection Device
CategoryThe connector    The connector   
File Size525KB,4 Pages
ManufacturerGlenair
Websitehttp://www.glenair.com/
Download Datasheet Parametric View All

803-013-AN8ZNU9-4NY-72 Overview

Interconnection Device

803-013-AN8ZNU9-4NY-72 Parametric

Parameter NameAttribute value
MakerGlenair
Reach Compliance Codecompliant
Connector typeINTERCONNECTION DEVICE
803-009
Abrasion-Resistant Polyurethane Jacket
provides cold temperature flexibility and
high strength. Low smoke/zero halogen
material meets requirements for low
toxicity.
90% Tinned Copper Braid
is terminated
directly to connector with stainless steel
BAND-IT®
strap.
Watertight Overmold
provides strain
relief and protection.
Overmolded Cordset
Series 803 Harsh Environment Shielded Cordsets
These overmolded cordsets withstand abrasion and chemical exposure. Low smoke zero halogen jacket reduces the amount of
toxic and corrosive gasses emitted during combustion. Cable construction features silver coated stranded conductors with TFE
insulation, tinned copper braid shield and extruded polyurethane jacket. Choose single-ended pigtails or double-ended "back-
to-back" versions. Braid shield is attached directly to connector with
BAND-IT®
straps. Semi-rigid polyamide overmold provides
strain relief and environmental sealing.
Series 801 cordsets are now available with size #20HD, #16 and #12 contacts. Ordering information is found on the following
pages.
F
HARSH ENVIRONMENT CORDSET SPECIFICATIONS
Cable Jacket Material
Cable Shield
Conductors
BAND-IT®
Shield Termination Band
Current Rating
Test Voltage (Dielectric Withstanding Voltage)
Insulation Resistance
Operating Temperature
Solvent Resistance, Polyamide Overmold
Shielding Effectiveness
Cable jacket Flammability and Toxicity
Thermoplastic Polyurethane, Black, Low-Smoke, Zero-Halogen
Tin-Coated Copper Braid, 90% Minimum Coverage
Silver Coated Stranded Wire, TFE Insulated, Per M22759/11
Stainless Steel
#23 5 Amps, #20HD 7.5 Amps, #16 13 Amps, #12 23 Amps
#23 500 VAC, #20HD 700 VAC, #16 and #12 1800 VAC Sea Level
200 megohms minimum
-30° C. to +105° C.
Excellent Resistance to Most Solvents, Fuels, and Oils; Poor Resistance to
Strong Acids and Bipolar Solvents (Alcohol)
50 dB minimum from 100MHz to 1000MHz.
Toxicity Index 3.9 per NES 713
Oxygen Index 28% per ASTM D-2863
Smoke Index 24 per NES 711
© 2010 Glenair, Inc.
www.glenair.com
Dimensions in inches (millimeters) and are subject to change without notice.
CAGE Code 06324
Printed in U.S.A.
E-Mail: sales@glenair.com
GLENAIR, INC. • 1211 AIR WAY • GLENDALE, CA 91201-2497 • 818-247-6000 • FAX 818-500-9912
F-15
01-JANUARY-2010
Series 803
Series 803 Mighty Mouse ¼ Turn Bayonet Coupling
Overmolded ASAP Cordset Ordering Information
USB self-powered setup not working
I developed a device using omap, using a USB interface, setting the USB device to self-powered, and setting the maximum current to 100mA. After plugging it into a PC, it can get 300mA of current and c...
seawave2000 Embedded System
Electronic competition exchange
[i=s]This post was last edited by paulhyde on 2014-9-15 03:02[/i] Could you please send me a copy, thanks, [url=mailto:1015133791@qq.com]1015133791@qq.com[/url]...
msayhello Electronics Design Contest
[AN-757 Application Note] ADN2812 acquisition time
Introduction: When the ADN2812 uses the default working mode (i.e. locking to the input data mode), it can automatically lock to the input data mode without programming and external reference clock as...
EEWORLD社区 ADI Reference Circuit
I have to say that the old technology I have been exposed to since 2008 was still blocked at that time.
1-3. Input and output matching circuit The purpose of the matching circuit is to choose a way of acceptance. For those transistors that want to provide greater gain, the way is to accept and output it...
btty038 RF/Wirelessly
【MicroPython】Micropython PM detection
[i=s]This post was last edited by lkl0305 on 2016-6-13 14:53[/i] Today I would like to share with you a small experiment on PM2.5 detection using Micropython, using the climbing laser pm2.5 sensor pms...
lkl0305 MicroPython Open Source section
Calibration of medical devices
Calibration of medical devices 1. Thermometer calibration - use black body furnace + constant temperature water bath to calibrate two points 2. Sphygmomanometer calibration - using BP pump sphygmomano...
QWE4562009 Test/Measurement

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2173  2427  2502  754  429  44  49  51  16  9 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号