EEWORLDEEWORLDEEWORLD

Part Number

Search

803-016-AB2ZNU14-235NY-72

Description
Interconnection Device
CategoryThe connector    The connector   
File Size525KB,4 Pages
ManufacturerGlenair
Websitehttp://www.glenair.com/
Download Datasheet Parametric View All

803-016-AB2ZNU14-235NY-72 Overview

Interconnection Device

803-016-AB2ZNU14-235NY-72 Parametric

Parameter NameAttribute value
MakerGlenair
Reach Compliance Codecompliant
Connector typeINTERCONNECTION DEVICE
803-009
Abrasion-Resistant Polyurethane Jacket
provides cold temperature flexibility and
high strength. Low smoke/zero halogen
material meets requirements for low
toxicity.
90% Tinned Copper Braid
is terminated
directly to connector with stainless steel
BAND-IT®
strap.
Watertight Overmold
provides strain
relief and protection.
Overmolded Cordset
Series 803 Harsh Environment Shielded Cordsets
These overmolded cordsets withstand abrasion and chemical exposure. Low smoke zero halogen jacket reduces the amount of
toxic and corrosive gasses emitted during combustion. Cable construction features silver coated stranded conductors with TFE
insulation, tinned copper braid shield and extruded polyurethane jacket. Choose single-ended pigtails or double-ended "back-
to-back" versions. Braid shield is attached directly to connector with
BAND-IT®
straps. Semi-rigid polyamide overmold provides
strain relief and environmental sealing.
Series 801 cordsets are now available with size #20HD, #16 and #12 contacts. Ordering information is found on the following
pages.
F
HARSH ENVIRONMENT CORDSET SPECIFICATIONS
Cable Jacket Material
Cable Shield
Conductors
BAND-IT®
Shield Termination Band
Current Rating
Test Voltage (Dielectric Withstanding Voltage)
Insulation Resistance
Operating Temperature
Solvent Resistance, Polyamide Overmold
Shielding Effectiveness
Cable jacket Flammability and Toxicity
Thermoplastic Polyurethane, Black, Low-Smoke, Zero-Halogen
Tin-Coated Copper Braid, 90% Minimum Coverage
Silver Coated Stranded Wire, TFE Insulated, Per M22759/11
Stainless Steel
#23 5 Amps, #20HD 7.5 Amps, #16 13 Amps, #12 23 Amps
#23 500 VAC, #20HD 700 VAC, #16 and #12 1800 VAC Sea Level
200 megohms minimum
-30° C. to +105° C.
Excellent Resistance to Most Solvents, Fuels, and Oils; Poor Resistance to
Strong Acids and Bipolar Solvents (Alcohol)
50 dB minimum from 100MHz to 1000MHz.
Toxicity Index 3.9 per NES 713
Oxygen Index 28% per ASTM D-2863
Smoke Index 24 per NES 711
© 2010 Glenair, Inc.
www.glenair.com
Dimensions in inches (millimeters) and are subject to change without notice.
CAGE Code 06324
Printed in U.S.A.
E-Mail: sales@glenair.com
GLENAIR, INC. • 1211 AIR WAY • GLENDALE, CA 91201-2497 • 818-247-6000 • FAX 818-500-9912
F-15
01-JANUARY-2010
Series 803
Series 803 Mighty Mouse ¼ Turn Bayonet Coupling
Overmolded ASAP Cordset Ordering Information
Wince connection timeout does not throw an exception
When the wince program calls the web service, it will not throw an exception when the network is not connected, and it will continue to connect. It can throw an exception on the simulator. Is there an...
方案公司 Embedded System
[Help] How to assign pointer to sbit variable on P port in C51?
The following statement is defined in C51: sbit P10 = P1^0; P10 needs to be referenced in the following module. Can a pointer be defined to point to P10? If yes, how should it be defined? In addition:...
lyn689 Embedded System
Is it difficult to do embedded system? How to learn embedded ARM? Do you need to work 996?
In the past, I always heard engineers who have worked for many years and have certain industry experience, or seniors, tell us how difficult it is to learn embedded systems and how high the threshold ...
嵌入式enjoy Linux and Android
I would like to ask about the RISC pipeline
I have learned about the characteristics of RISC, but I still don't understand how the pipeline method can improve the efficiency of instruction execution? Because even though the instructions are pip...
utadahikaru Embedded System
Is the 485 isolation method shown in the figure correct?
...
飞鸿浩劫 Integrated technical exchanges
Analysis and Research on GSM Mobile Phone Radio Frequency System (VI)
GMSK signal analysisTherefore, we try to analyze by modifying the Gaussian filter and starting from B. Now many domestic mobile phones use GMSK modulation with BT=0.3, which requires adjacent channel ...
JasonYoo RF/Wirelessly

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2379  1766  2492  1397  1979  48  36  51  29  40 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号