EEWORLDEEWORLDEEWORLD

Part Number

Search

804-002-06C15-85SA

Description
Circular Connector, 85 Contact(s), Aluminum Alloy, Female, Plug,
CategoryThe connector    The connector   
File Size120KB,2 Pages
ManufacturerGlenair
Websitehttp://www.glenair.com/
Environmental Compliance  
Download Datasheet Parametric View All

804-002-06C15-85SA Overview

Circular Connector, 85 Contact(s), Aluminum Alloy, Female, Plug,

804-002-06C15-85SA Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerGlenair
Reach Compliance Codecompliant
Other featuresPOLARIZED
Back shell typeSOLID
Body/casing typePLUG
Connector typeCIRCULAR CONNECTOR
Contact to complete cooperationNOT SPECIFIED
Contact point genderFEMALE
Contact materialNOT SPECIFIED
Coupling typeSNAP
DIN complianceNO
empty shellNO
Filter functionNO
IEC complianceNO
MIL complianceNO
Plug informationMULTIPLE MATING PARTS AVAILABLE
Mixed contactsNO
Installation typeCABLE
OptionsGENERAL PURPOSE
Shell surfaceANODIZED BLACK
Shell materialALUMINUM ALLOY
Housing size15
Total number of contacts85
A
B
C
Series 804 Plug Connector
Quick Disconnect
These plugs snap
securely into receptacle housings
and release with a simple pull.
Two Keying Styles:
A single master
key provides fast mating in low-light
situations, or specify three keys for
more polarizing options.
Two Shell Styles:
Integral platform
for direct shield attachment using
the
BAND-IT
®
termination system, or
an accessory thread for attaching a
strain relief.
D
E
F
G
H
804-002
804-001
Plug with Banding
Platform
J
K
L
M
© 2007 Glenair, Inc.
CAGE Code 06324
Printed in U.S.A.
Series 804
Series 804 “Mighty Mouse”
Push-Pull Quick-Disconnect
Series 804 Plug Connectors
HOW TO ORDER
Sample Part Number
804-001
Series
-06
Shell Style
-06
Plug
M
Shell Material /
Finish
C
Aluminum / Black
Anodize
9-19
Shell Size- Insert
Arrangement
5-3
6-1
6-4
6-7
7-1
7-10
8-13
9-4
9-19
10-26
12-2
12-37
14-55
15-85
3 #23 Contacts
1 #16 Contact
4 #23 Contacts
7 #23 Contacts
1 #12 Contact
10 #23 Contacts
13 #23 Contacts
4 #16 Contacts
19 #23 Contacts
26 #23 Contacts
2 #12 Contacts
37 #23 Contacts
55 #23 Contacts
85 #23 Contacts
S
Contact Type
Standard #23 contacts accept
#22 through #28 AWG wire. Use
the following contact codes to
specify these contacts:
Shell Key
Position
Omit
for Single
Master Key
M
Aluminum /
Electroless Nickel
P
Pin
NF
Aluminum / Cadmium
with Olive Drab
Chromate
S
Socket
Special contacts for #26 to #30
AWG are also available. Use
the following contact codes to
specify these contacts:
Pos. A
(Normal)
A
ZN
Plug with
Accessory
Thread
Aluminum / Zinc-
Nickel with Olive Drab
Chromate
Pos. B
B
C
D
Pos. C
G
Pin
ZNU
Aluminum / Zinc-
Nickel with Black
Chromate
#23 contacts are packaged
with connectors. #16 and #12
contacts must be ordered
separately.
Pos. D
H
Socket
Z1
Stainless Steel /
Passivated
GLENAIR, INC. • 1211 AIR WAY • GLENDALE, CA 91201-2497 • 818-247-6000 • FAX 818-500-9912
www.glenair.com
G-4
Rev. 05-APR-2007
E-Mail: sales@glenair.com
Realization of medical monitoring system based on infrared technology
In hospitals, monitoring systems are essential for better care of patients or for medical observation and research. Most hospitals now use television systems and low-light monitoring systems, which ha...
dtcxn Medical Electronics
MSP430 IIC communication
#includemsp430f149.h#define OP_READ 0xa1//器件地址读 #define OP_WRITE 0xa0//器件地址写 #define uchar unsigned char #define uint unsigned int #define SDA_OUT P1DIR |= BIT3 #define SDA_IN P1DIR = ~BIT3 #define SC...
火辣西米秀 Microcontroller MCU
The role of parallel resistance on the capacitor of the integration circuit
I saw in the book (The Art of Electronics) "If the residual drift of the integrator is still too large for a given application, it may be necessary to put a large resistor R2 across C to provide dc fe...
PCB板 Analog electronics
Award-winning live broadcast: ON Semiconductor's advanced packaging and driver technologies help silicon carbide energy applications in progress
Award-winning live broadcast: ON Semiconductor's advanced packaging and driver technologies help silicon carbide energy applications in progressClick here to enter the live broadcastLive broadcast tim...
EEWORLD社区 Power technology
AD conversion interruption problem of MSP430F149
During hardware simulation, after the interrupt flag ADC12IFG is set, the interrupt subroutine is entered. However, whether reading ADC12MEM or resetting by software, such as directly ADC12IFG&=0x00;,...
bbslb Microcontroller MCU
[DLP course recommendation] no zuo no die, Xiaozuo DLP
[i=s]This post was last edited by ljj3166 on 2016-8-26 15:41[/i] Personally, I feel that DLP technology is not a very new technology. It is just that it has been monopolized by some companies for so m...
ljj3166 TI Technology Forum

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 194  486  1122  2171  1432  4  10  23  44  29 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号