EEWORLDEEWORLDEEWORLD

Part Number

Search

804-002-06M6-7GC

Description
Circular Connector, 7 Contact(s), Aluminum Alloy, Male, Plug,
CategoryThe connector    The connector   
File Size120KB,2 Pages
ManufacturerGlenair
Websitehttp://www.glenair.com/
Environmental Compliance  
Download Datasheet Parametric View All

804-002-06M6-7GC Overview

Circular Connector, 7 Contact(s), Aluminum Alloy, Male, Plug,

804-002-06M6-7GC Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerGlenair
Reach Compliance Codecompliant
ECCN codeEAR99
Other featuresPOLARIZED
Back shell typeSOLID
Body/casing typePLUG
Connector typeCIRCULAR CONNECTOR
Contact to complete cooperationNOT SPECIFIED
Contact point genderMALE
Contact materialNOT SPECIFIED
Coupling typeSNAP
DIN complianceNO
empty shellNO
Filter functionNO
IEC complianceNO
MIL complianceNO
Plug informationMULTIPLE MATING PARTS AVAILABLE
Mixed contactsNO
Installation typeCABLE
OptionsGENERAL PURPOSE
Shell surfaceNICKEL
Shell materialALUMINUM ALLOY
Housing size6
Total number of contacts7
A
B
C
Series 804 Plug Connector
Quick Disconnect
These plugs snap
securely into receptacle housings
and release with a simple pull.
Two Keying Styles:
A single master
key provides fast mating in low-light
situations, or specify three keys for
more polarizing options.
Two Shell Styles:
Integral platform
for direct shield attachment using
the
BAND-IT
®
termination system, or
an accessory thread for attaching a
strain relief.
D
E
F
G
H
804-002
804-001
Plug with Banding
Platform
J
K
L
M
© 2007 Glenair, Inc.
CAGE Code 06324
Printed in U.S.A.
Series 804
Series 804 “Mighty Mouse”
Push-Pull Quick-Disconnect
Series 804 Plug Connectors
HOW TO ORDER
Sample Part Number
804-001
Series
-06
Shell Style
-06
Plug
M
Shell Material /
Finish
C
Aluminum / Black
Anodize
9-19
Shell Size- Insert
Arrangement
5-3
6-1
6-4
6-7
7-1
7-10
8-13
9-4
9-19
10-26
12-2
12-37
14-55
15-85
3 #23 Contacts
1 #16 Contact
4 #23 Contacts
7 #23 Contacts
1 #12 Contact
10 #23 Contacts
13 #23 Contacts
4 #16 Contacts
19 #23 Contacts
26 #23 Contacts
2 #12 Contacts
37 #23 Contacts
55 #23 Contacts
85 #23 Contacts
S
Contact Type
Standard #23 contacts accept
#22 through #28 AWG wire. Use
the following contact codes to
specify these contacts:
Shell Key
Position
Omit
for Single
Master Key
M
Aluminum /
Electroless Nickel
P
Pin
NF
Aluminum / Cadmium
with Olive Drab
Chromate
S
Socket
Special contacts for #26 to #30
AWG are also available. Use
the following contact codes to
specify these contacts:
Pos. A
(Normal)
A
ZN
Plug with
Accessory
Thread
Aluminum / Zinc-
Nickel with Olive Drab
Chromate
Pos. B
B
C
D
Pos. C
G
Pin
ZNU
Aluminum / Zinc-
Nickel with Black
Chromate
#23 contacts are packaged
with connectors. #16 and #12
contacts must be ordered
separately.
Pos. D
H
Socket
Z1
Stainless Steel /
Passivated
GLENAIR, INC. • 1211 AIR WAY • GLENDALE, CA 91201-2497 • 818-247-6000 • FAX 818-500-9912
www.glenair.com
G-4
Rev. 05-APR-2007
E-Mail: sales@glenair.com
LCD screen white screen
I recently adjusted the LCD display, but I still don't know much about it. Does anyone know the reasons for a white screen? I know there may be many. Can you tell me what are the common ones? Also, wh...
chen_jia_ Embedded System
I'm a newbie posting, please don't criticize me, seniors.
I'm a newbie posting, please don't criticize me, seniors! I'm new to MSP430....
经世致用 Microcontroller MCU
Is there anyone who still uses 2D laser engraving machines? Full range of functions, both software and hardware (Part 2) Upgrading from a musket to a cannon
[size=14px]The plotter converted from the optical drive is too small, so I dismantled my scanner-printer at home and converted it into a large plotter. (Of course the printer is broken)[/size] [img=31...
zhengjingwen DIY/Open Source Hardware
How to implement without PLC
First, the conveyor belt rotates, and then stops when it touches the proximity switch. At this time, the solenoid valve opens, and moves downward after opening. It does not stop after touching the low...
121hhhhhh Industrial Control Electronics
VC2005 is an upgraded version of VC6.0. I wonder if it can also be considered an upgraded version of EVC4.0?
1.VC2005 is an upgraded version of VC6.0. I wonder if it is also an upgraded version of EVC4.0? 2.Can the project using EVC be moved to VC2005? 3.In addition, why does it prompt "automation server can...
davidzjq Embedded System
【LaunchPad】Development board introduction
Introduction to LaunchPad Development Board Preface Everyone has received a super cheap LaunchPad development board. Some friends use it for learning, while others just buy one because it is cheap. No...
wstt Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 704  813  1217  2920  1300  15  17  25  59  27 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号