EEWORLDEEWORLDEEWORLD

Part Number

Search

804-004-02Z18-7PB

Description
Circular Connector, 7 Contact(s), Stainless Steel, Male, Crimp Terminal, Receptacle,
CategoryThe connector    The connector   
File Size380KB,4 Pages
ManufacturerGlenair
Websitehttp://www.glenair.com/
Download Datasheet Parametric View All

804-004-02Z18-7PB Overview

Circular Connector, 7 Contact(s), Stainless Steel, Male, Crimp Terminal, Receptacle,

804-004-02Z18-7PB Parametric

Parameter NameAttribute value
MakerGlenair
Reach Compliance Codecompliant
Back shell typeSOLID
Body/casing typeRECEPTACLE
Connector typeCIRCULAR CONNECTOR
Contact to complete cooperationNOT SPECIFIED
Contact point genderMALE
Coupling typeTHREADED
DIN complianceNO
empty shellNO
Filter functionNO
IEC complianceNO
MIL complianceNO
Plug informationMULTIPLE MATING PARTS AVAILABLE
Mixed contactsNO
Installation typeCABLE AND PANEL
OptionsGENERAL PURPOSE
Shell materialSTAINLESS STEEL
Housing size8
Termination typeCRIMP
Total number of contacts7
A
B
C
D
E
F
G
H
J
K
L
M
© 2007 Glenair, Inc.
Series 805
Series 805 “Mighty Mouse”
Triple-Start
Series 805 Receptacles
Three Shell Mounting Options:
Jam nut with o-ring for rear panel
mounting, square flange for front
or rear panel mounting, or in-line
receptacles for free-hanging cables.
Two Shell Styles:
Choose
integral
band platform
for direct attachment
of a cable shield. Install a boot,
or overmold a boot over the band
platform.
Gold-Plated Crimp Contacts
are held in place with beryllium
copper retention clips. Contacts are
removable.
Series 805 Triple-Start
Jam Nut Connector
An
accessory thread
is available
for attaching strain reliefs and
backshells.
HOW TO ORDER
Sample Part Number
80 5- 0 0 4
Series
-02
Shell Style
NF
Shell Material /
Finish
C
Aluminum / Black
Anodize
9-10
Shell Size- Insert
Arrangement
1 #16 Contact
4 #23 Contacts
7 #23 Contacts
1 #12 Contact
10 #23 Contacts
13 #23 Contacts
4 #16 Contacts
19 #23 Contacts
26 #23 Contacts
2 #12 Contacts
15-37
37 #23 Contacts
18-55
55 #23 Contacts
19-85
85 #23 Contacts
Size #23 contacts are
supplied with connectors.
Other contact sizes are
ordered separately.
P
Contact Type
Standard #23 contacts
accept #22 through
#28 AWG wire. Use the
following contact codes
to specify these contacts:
A
Shell Key
Position
A
Position A
(Normal)
M
-01
805-003
Receptacle with
Banding Platform
In-Line
Aluminum / Electroless
Nickel
NF
Aluminum / Cadmium
with Olive Drab
Chromate
8-1
8-4
8-7
9-1
9-10
10-13
11-4
11-19
12-26
15-2
B
Position B
P
Pin
C
Position C
S
Socket
Special contacts for
#26 to #30 AWG are
also available. Use the
following contact codes
to specify these contacts:
D
Position D
ZN
-02
Square Flange
Aluminum / Zinc-
Nickel with Olive Drab
Chromate
805-004
Receptacle with
Accessory Thread
-07
Jam Nut for Rear
Panel Mounting
ZNU
Aluminum / Zinc-Nickel
with Black Chromate
G
Pin
Z1
Stainless Steel /
Passivated
H
Socket
CAGE Code 06324
Printed in U.S.A.
GLENAIR, INC. • 1211 AIR WAY • GLENDALE, CA 91201-2497 • 818-247-6000 • FAX 818-500-9912
www.glenair.com
H-6
Rev. 05-APR-2007
E-Mail: sales@glenair.com
Power supply noise interference processing
一般而言,电源杂讯干扰的传播途径可分为下列二大类:??一、普通模式(Normal Mode):简称通模,指的就是二组输入电源线之间的杂讯。这些杂讯大多是由开关动作或者是静态功率转换器等干扰所造成,当这些干扰与正常讯号重叠在一起时,器材元件是无法分辨的,因为正常讯号也是以通模的状态存在。 ??二、共通模式(Common Mode):简称共模,指的是电源与接地之间的杂讯。这部分杂讯的起因多数是因为接地...
songbo Industrial Control Electronics
Principle of LED brightness control by microcontroller MCU
Microcontrollers MCU are usually considered digital devices. By default, their output voltage level is either high or low, not a neutral value. To achieve the requirement of LED brightness control, th...
火辣西米秀 Microcontroller MCU
Can the register secondary latch be latched correctly?
always@(posedge clk or negedge rst_n) begin ......... areg1<=a; areg2<=areg1; .... end assign a=~areg1& areg2;//High level is valid always@(posedge clk or negedge rst_n) begin ........... if(a) .........
1559638992 FPGA/CPLD
TI's BQ2057 charging current is only 200mA. Please give me some advice based on the picture above!
Using a 5V2A adapter, a lithium battery is fully charged to 4.1V, but the charging current is less than 200mA, the charging speed is too slow. See the picture, please improve...
ZHANGXU716 Analogue and Mixed Signal
[Transfer] Common questions in op amp learning
[i=s] This post was last edited by dontium on 2015-1-23 11:31 [/i] [b]1. What is the function of adding a small resistor to the output of the op amp? [/b] Answer: The protection method for short-circu...
模拟IC Analogue and Mixed Signal
A Deeper Study of "Ground" in Circuits
[i=s]This post was last edited by ohahaha on 2015-12-4 14:21[/i] [color=rgb(62,62,62)][align=left][Repost] If someone asks "Is there a universal grounding method that can be used as a reference?" I wi...
ohahaha Energy Infrastructure?

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1087  212  349  2274  1368  22  5  8  46  28 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号