EEWORLDEEWORLDEEWORLD

Part Number

Search

2200AAH6004B3EB

Description
Strain Guage Sensor, Absolute, 0Psi Min, 6000Psi Max, 0.15%, 100mV, Cylindrical
CategoryThe sensor    Sensor/transducer   
File Size507KB,4 Pages
ManufacturerGems Sensors & Controls
Download Datasheet Parametric View All

2200AAH6004B3EB Overview

Strain Guage Sensor, Absolute, 0Psi Min, 6000Psi Max, 0.15%, 100mV, Cylindrical

2200AAH6004B3EB Parametric

Parameter NameAttribute value
Is it Rohs certified?incompatible
Reach Compliance Codeunknow
Maximum accuracy(%)0.15%
shellSTAINLESS STEEL
Maximum operating temperature125 °C
Minimum operating temperature-40 °C
Output range100mV
Output typeANALOG VOLTAGE
Package Shape/FormCYLINDRICAL
port type7/16 MALE
Maximum pressure range6000 Psi
Minimum pressure range
Pressure sensing modeABSOLUTE
Sensor/Transducer TypePRESSURE SENSOR,STRAIN GUAGE
Maximum supply voltage15 V
Minimum supply voltage10 V
Termination typeDIN 9.4MM W/O MATE
Base Number Matches1
Please tell me about the electromagnetic field formula
I would like to ask what is the difference between 1 and 2 in the following formula, and how the three terms on the right side of the formula are derived? I don’t understand, so please explain it to m...
深圳小花 MCU
What instruments and equipment do I need to buy to apply wireless sensors?
My laboratory is a general department in the field of national defense. In the past, it rarely involved electronics. In order to expand the application direction, I am preparing to invest in some comm...
joshua Embedded System
The high-definition craze has set off. Only by getting rid of misunderstandings can the value of high-definition be realized
At present, the high-definition craze has been set off, and video surveillance has begun to take full high-definition as a new goal. People have always been pursuing clear images, so the current high-...
xyh_521 Industrial Control Electronics
GPS solution with integrated multimedia functions
[b]Overview of Satellite Positioning[/b] The basic principle of global satellite navigation is: satellites transmit navigation messages, which include ranging precision factor, Kepler parameters, orbi...
jek9528 Industrial Control Electronics
What does this error mean when compiling a Protel schematic?
What does this error mean when compiling a Protel schematic?...
576483498 PCB Design
The value read by IIC from eeprom is different from the value written into it, and the value read from eeprom does not change when the written value is changed.
As the title says. /*************************************************************************** IIC bus reads 8-bit data return value: the read 8-bit data**********************************************...
墨染卿卿 Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2148  2742  2185  338  1033  44  56  7  21  28 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号