FTR-K1 SERIES
POWER RELAY
1 POLE - 6A Slim Type (Medium Load Control)
FTR-LY Series
n
FEATURES
Slim 15.0mm (h) x 5.0 mm (w) x 28.0mm (l)
l
1 form C and right angle type available
2
l
Mounting space: 140mm , weight: 5.0g
l
High insulation in small package
Insulation distance (between coil and contacts): 8mm
(creepage/clearance)
Dielectric strength: 4,000 VAC
Surge strength: 6,000V
l
Plastic sealed type RTIII
l
UL, CSA, VDE, SEMKO, FIMKO, DEMKO, NEMKO
compliance
l
Socket type available
l
RoHS compliant
Please see page 7 for more information
l
n
PARTNUMBER INFORMATION
FTR-LY
(a)
A
(b)
A
(c)
[Example]
005 Y - SK
(d) (e)
(f )
(a)
(b)
Relay type
Contact configuration
FTR-LY : FTR-LY-Series
A
C
P
R
A
005
E
Y
V
Nil
SK
: 1 form A
: 1 form C
: 1 form A (right angle type)
: 1 form C (right angle type)
: Standard type (170mW)
: 5.....60 VDC
Coil rating table at page 3
: AgNi
: AgSnO
2
: AgSnO
2
+ Au (0.3µm)
: PCB mounting type
: Socket mounting type (only contact configuration A and C
(c)
(d)
(e)
Coil type
Coil rated voltage
Contact material
(f)
Special type
Actual marking does not carry the type name : "FTR" and "SK"
E.g.: Ordering code: FTR-LYAA005Y-SK Actual marking: LYAA005Y
1
FTR-K1 SERIES
FTR-LY SERIES
n
SPECIFICATION
Item
Contact Data
Configuration
Construction
Material
Resistance (initial)
Contact rating
Max. carrying current
Max. switching voltage
Max. switching power
Min. switching load *
Life
Mechanical
Electrical
Coil Data
Rated power
Operate power
Operating temperature range
Timing Data
Insulation
Operate (at nominal voltage)
Release (at nominal voltage)
Resistance (initial)
Dielectric strength
Surge strength
Clearance
Creepage
EN61810-1, VDE0435
Voltage
Pollution degree
Material group
Category
Other
Vibration resistance
Shock
Weight
Sealing
Misoperation
Endurance
Misoperation
Endurance
Open contacts
Contacts to coil
Coil to contacts
LY (C,R) A ( ) (Y,E,V)
1 form C (SPDT)
Single
Y: AgSnO
2
/ E: AgNi / V: AgSnO
2
+ Au 0.3µm
Y, E: Max. 100 mΩ at 6 VDC, 1 A
V: Max. 30 mΩ at 6 VDC, 1A
6A, 250VAC / 24VDC
6A
250VAC
1,500VA / 144W
Y, E: 100 mA 5 VDC
V: 10mA 5 VDC
Min. 10 x 10
6
operations
Min. 50 x 10
3
operations (N.O.)
Min. 30 x 10
3
operations (N.C.) at 6A, 250VAC / 30VDC
resistive
170 to 217 mW
74 to 76 mW
-40 °C to +85 °C (no frost)
Max. 8ms (no diode, without bounce)
Max. 4ms (no diode, without bounce)
Min. 1,000MΩ at 500VDC
1,000VAC (50/60Hz) 1min.,10mA detection current
4,000VAC (50/60Hz) 1min.,10mA detection current
6,000V / 1.2 x 50µs standard wave
8 mm
8 mm
250V
3
III a
C / 250V
10 to 55Hz double amplitude 1.0mm
10 to 55Hz double amplitude 1.5mm
Min. 50m/s² (11 ± 1ms)
Min. 1,000m/s² (6 ± 1ms)
Approximately 5 g
Plastic sealed RTIII
Min. 100m/s² (11 ± 1ms)
LY (A,P) A ( ) (Y,E,V)
1 form A (SPST-NO)
* Minimum switching loads mentioned above are reference values. Please perform the confirmation test with actual
load before production since reference values may vary according to switching frequencies, environmental conditions
and expected reliability levels.
2
FTR-K1 SERIES
FTR-LY SERIES
n
COIL RATING
Coil
Code
005
006
009
012
018
024
048
060
Rated Coil
Voltage
(VDC)
5
6
9
12
18
24
48
60
Coil Resistance
+/- 10% (Ohm)
147
211
476
847
1,910
3,390
10,600
20,570
Must Operate
Voltage
(VDC) *
3.3
4
5.9
7.9
11.9
15.9
31.7
39.6
Must Release-
Voltage
(VDC) *
0.25
0.3
0.45
0.6
0.9
1.2
2.4
3
Max. Coil Voltage
(VDC)
11.5
13.8
20.7
27.6
41.4
55.2
110.4
138
217
175
170
Rated Power
(mW)
Note: All values in the table are valid for 20°C and zero contact current.
* Specified operate values are valid for pulse wave voltage.
n
UL
SAFETY STANDARDS
Compliance
UL 508
E63614
Contact rating
Flammability: UL 94-V0 (plastics)
5A, 277 VAC (resistive)
5A, 30 VDC (resistive)
1/10 HP, 277VAC /125VAC
Pilot duty: D300, C300, R300, B300
250VAC; 6A / 30VDC; 6A :
- 10K ops. FTR-LY(A;P)A...(E;Y;V) -40 °C to +85 °C
- 5K ops. FTR-LY(C;R)A...(E;Y;V) -40 °C to +85 °C
250VAC; 6(1,5)A, 30K ops. : FTR-LY(A;P)A...(Y;V) +85 °C
250VAC; 3(1,5)A, 100K ops. : FTR-LY(A;P)A...(Y;V) +85 °C
Type
CSA
VDE
40006591
C22.2 No. 14
LR 40304
EN 61810-1 (VDE 0435-Part 201)
2004-07
EN 60730-1 (VDE 0631-Part 1)
EN 61984 (VDE 0627)
EN 60335-1 (VDE 0700-Part 1)
-
3
FTR-K1 SERIES
FTR-LY SERIES
n
CHARACTERISTIC DATA
4
FTR-K1 SERIES
FTR-LY SERIES
n
DIMENSIONS
Straight terminal type
l
Dimensions
l
Schematics
l
PC board mounting
hole layout
(BOTTOM VIEW)
Right angle type
l
Dimensions
l
Schematics
l
PC board mounting
hole layout
(BOTTOM VIEW)
Unit: mm
* This terminal is not applicable for 1 form A type.
5