Model JEC DC-DC Long Stroke LVDT
Order Code AY321
n
n
n
Stainless Steel
Voltage Regulation
Reverse Polarity Protected
Wiring Code
Dual Supply
Red
Blue
Black
+12 to +20 V Input
-12 to -20 V Input
OV, I/P, O/P Common
Dimensions
M5 x .08
0.35 in.
L
X Nominal
Electric
Zero Point
ø 0.19 in.
Single Supply (*floating)
Red
Blue
Approx.
Armature
Weight
(oz.)
1.0
2.0
2.5
3.0
3.5
4.0
5.0
Outputs
Yellow
Green
0-10 Volt
+/- 5 VDC
+24 to +40 V Input
Supply Negative
ø 0.81 in.
Range
Codes
HP
HQ
HR
HS
HT
HU
HV
Available
Stroke
Ranges
+/- 0.5 in.
+/- 1.0 in.
+/- 2.0 in.
+/- 3.0 in.
+/- 4.0 in.
+/- 6.0 in.
+/- 8.0 in.
L (in.)
6.9
8.0
12.5
16.9
18.7
26.2
33.7
X (in.)
1.7
2.7
3.2
4.7
5.2
7.2
10.2
Approx.
Body
Weight
(oz.)
7.5
9.5
13.0
17.5
22.0
30.0
44.0
*Output common floats at voltage source/ 2
Performance
Stroke Range................+/- 0.5 to 8.0 in.
Non-Linearity (max.)................+/- 0.25% Full Scale
Output Load (min.)................2,000 Ohms with 3-wire supply, 20,000 Ohms with floating supply
Output Impedance................2 Ohms
Output Sensitivity................+/- 5 VDC or 0-10 VDC (field selectable)
Isolation................1,000 V input to output
Polarity................Output is positive for outward stroke
Temperature, Operating................-58° to 176°F
Temperature, Effect
Zero (max.)................0.006% Full Scale/°F
Span (max.)................0.017% Full Scale/°F
Element Type................DC-DC LVDT
Power Supply
Single Supply................+24 to +40 VDC @ 30 mA
Dual Supply................+/-12 to +/-24 VDC @ 30 mA
Ripple................30 mV peak to peak
Electrical Termination................Multiconductor Shielded Cable (6 ft.)
Reverse Polarity Protection................Yes
Material................Stainless Steel
Probe Material................Stainless Steel
Armature Type................Free Unguided
Probe Thread................M5 x 0.8
Weight................See Above Table
Spring Force (max.)................Not Applicable
Environmental
Electrical
Mechanical
348
1-888-282-9891
www.honeywell.com/sensotec
Model JEC
Typical System Diagram
Customer Supplied
Chart Recorder
Alarm Panel
Data Acquisition
Computer
PLC
Model JEC
Mounting Blocks
AA937
High Level Input Display Units
GM-A (note 1)
SC500
SC1000
SC2000
SC3004
Mounting Options
Rod End Bearing
DC Power Supply
Required if high level input
display unit is not being
used.
Options
Fast Track Delivery
Stroke Ranges
+/- 0.5 to 8.0 in.
TM405. Axial Bendix connector
Multiconductor Shielded Cable
on body Radial (side)
TM406. Bendix connector on
(6 ft.)
body
TM49. Axial cable exit
TM511. 13/16 - 32 UNF
L10. +/- 0.1% max. linearity
(less than or equal to +/- 4 in.)
Built to Order
Range Codes
Range
+/-
+/-
+/-
+/-
+/-
+/-
+/-
0.5
1.0
2.0
3.0
4.0
6.0
8.0
in.
in.
in.
in.
in.
in.
in.
Range Code
HP
HQ
HR
HS
HT
HU
HV
Electrical
Termination
Electrical Cable
Orientation
Mounting Threads
Improved
Linearity
Supplied as standard
Notes
1. GM-A should not be used with an amplified LVDT unless
using an external power supply to power the LVDT.
Special Customer Requirements
(Consult Factory)
T.E.D.S. IEEE 1451.4 module
Signature Calibration
-Not RoHS Compliant
How to Order
The order code consists of the product model, the desired range code and the available options.
Sample Code:
AY321
Model Code
HQ
Range Code
L10
Options Code
1-888-282-9891
www.honeywell.com/sensotec
349