2200CGH1001F2EB

Description
Strain Guage Sensor, Gage, 0Psi Min, 1000Psi Max, 0.15%, 1-6V, Cylindrical
CategoryThe sensor    Sensor/transducer   
File Size507KB,4 Pages
ManufacturerGems Sensors & Controls
Download Datasheet Parametric View All

2200CGH1001F2EB Overview

Strain Guage Sensor, Gage, 0Psi Min, 1000Psi Max, 0.15%, 1-6V, Cylindrical

2200CGH1001F2EB Parametric

Parameter NameAttribute value
Is it Rohs certified?incompatible
Reach Compliance Codeunknow
Maximum accuracy(%)0.15%
shellSTAINLESS STEEL
Nominal offset1V
Maximum operating temperature50 °C
Minimum operating temperature-20 °C
Output range1-6V
Output typeANALOG VOLTAGE
Package Shape/FormCYLINDRICAL
port typeG1/4 MALE
Maximum pressure range1000 Psi
Minimum pressure range
Pressure sensing modeGAGE
Sensor/Transducer TypePRESSURE SENSOR,STRAIN GUAGE
Maximum supply voltage35 V
Minimum supply voltage1.5 V
Termination typeMETAL CABLE GLAND
Base Number Matches1
About RAMIMAGE and ROMIMAGE
NK 8C100000 01EB0000 RAMIMAGE ROMSTART=8C100000 RAMIMAGE and ROMSTART overlap in virtual address. I know this is correct. But I don't know why?...
hanxu Embedded System
Who can introduce the functions of several public files of STM32 cortex-M3
Could anyone tell me what these files are used for? stm32f10x_vector.c, cortexm3_macro.s, stm32f10x_flash.icf,stm32f10x_nor.icf,stm32f10x_extsram.icf, stm32f10x_ram.icf. Thanks! It would be best if yo...
xiaotian189 stm32/stm8
Graduation thesis help~~~~
I am writing a paper on designing an electronic scale using a single-chip microcomputer. I hope someone can help me find some examples. Thank you. Email: lzw798@163.com...
lizhouwen MCU
I would like to ask a question about the analog circuit of the oscilloscope signal acquisition front end.
[size=4][backcolor=rgb(239, 245, 249)]This circuit is at the front end of the input of a simple oscilloscope. The function should be to select the AC sampling mode and the DC sampling mode, and to div...
6688hyc Analog electronics
Model 2602 SourceMeter System Setup for LIV Testing
The entire LIV test can be written as a test sequence or script. In this script, the SMUA channel of the Model 2602 is programmed to perform a current sweep from 0 to 100 mA , with 100 steps of 1 mA ....
Jack_ma Test/Measurement
How does Allegro create a thermal pad with vias?
Dear forum friends, when I used Allegro to make [color=#0066cc]package[/color] recently, I needed to use a heat dissipation pad with vias. One idea I had was: use Pad Designer to create a pad, and mak...
文心雕龙7 PCB Design

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 81  2650  692  1879  2256  2  54  14  38  46 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号