EEWORLDEEWORLDEEWORLD

Part Number

Search

54122-419-56-1150LF

Description
Board Connector, 112 Contact(s), 2 Row(s), Male, Straight, 0.1 inch Pitch, Solder Terminal, Locking, Black Insulator, Receptacle
CategoryThe connector    The connector   
File Size107KB,1 Pages
ManufacturerAmphenol
Websitehttp://www.amphenol.com/
Environmental Compliance
Download Datasheet Parametric View All

54122-419-56-1150LF Overview

Board Connector, 112 Contact(s), 2 Row(s), Male, Straight, 0.1 inch Pitch, Solder Terminal, Locking, Black Insulator, Receptacle

54122-419-56-1150LF Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
MakerAmphenol
Reach Compliance Codecompliant
body width0.19 inch
subject depth0.453 inch
body length5.6 inch
Body/casing typeRECEPTACLE
Connector typeBOARD CONNECTOR
Contact to complete cooperationSN ON NI
Contact completed and terminatedMatte Tin (Sn) - with Nickel (Ni) barrier
Contact point genderMALE
Contact materialPHOSPHOR BRONZE
contact modeRECTANGULAR
Contact styleSQ PIN-SKT
Insulation resistance5000000000 Ω
Insulator colorBLACK
insulator materialTHERMOPLASTIC
JESD-609 codee3
Manufacturer's serial number54122
Plug contact pitch0.1 inch
Match contact row spacing0.1 inch
Installation option 1LOCKING
Installation methodSTRAIGHT
Installation typeBOARD
Number of connectorsONE
PCB row number2
Number of rows loaded2
Maximum operating temperature125 °C
Minimum operating temperature-65 °C
PCB contact patternRECTANGULAR
PCB contact row spacing2.54 mm
Plating thickness79u inch
Rated current (signal)3 A
GuidelineUL, CSA
reliabilityCOMMERCIAL
Terminal length0.12 inch
Terminal pitch2.54 mm
Termination typeSOLDER
Total number of contacts112
PDM: Rev:K
STATUS:
Released
Printed: Mar 10, 2011
.
LightSpeed VCT64 row CT bed lifting fault repair
Shaanxi Jiuxiang Electronic Technology Co., Ltd. Engineer: Yu Qinqing Machine model: LightSpeed VCT Fault phenomenon: The bed cannot rise normally. The fault of this machine is manifested as the bed d...
迎春 Medical Electronics
Three-phase brushless sensorless DC motor tester
The three-phase brushless sensorless DC motor tester is Feiying Jiale's latest generation of testing instruments specifically for three-phase brushless Hall sensorless DC motors. This product has stro...
fyjl520 Test/Measurement
Do you wear a mask when you go out on a smoggy day?
[font=微软雅黑][size=3] Today, the capital is covered with smog again. When I came to work this morning, I saw many people wearing familiar "equipment" again:cold: There are round ones, square ones... It ...
eric_wang Talking
[Sipeed LicheeRV 86 Panel Review] 3-System Burn-in Test
This article introduces the system burning method of LicheeRV 86 development board Burning environment construction First, download the burning software , the address is here: https://dl.sipeed.com/sh...
DDZZ669 Domestic Chip Exchange
[Unbearable BUG] Solve the problem that Chronos watches cannot read time (Copy System Time)
I just got the Chronos watch and found this BUG. I saw many people in the forum encountered this problem, now I learned TCL and found the reason. The principle is as follows: Chronos Control Center (C...
southwolf1813 Microcontroller MCU
Ask about the flyback reflected voltage
The input voltage is 85-265V. Is the reflected voltage a variable that changes with the input voltage? If the maximum duty cycle is set by yourself, how do you calculate the transformer turns ratio?...
wangguangping LED Zone

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 467  2629  2654  1482  2747  10  53  54  30  56 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号