EEWORLDEEWORLDEEWORLD

Part Number

Search

M30JM--000046-15KPC

Description
Peizoresistive Sensor, Compound, 0Psi Min, 15000Psi Max, 1%, Cylindrical
CategoryThe sensor   
File Size331KB,7 Pages
ManufacturerTE Connectivity
Websitehttp://www.te.com
Environmental Compliance
Download Datasheet Parametric View All

M30JM--000046-15KPC Overview

Peizoresistive Sensor, Compound, 0Psi Min, 15000Psi Max, 1%, Cylindrical

M30JM--000046-15KPC Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
MakerTE Connectivity
Reach Compliance Codeunknown
Maximum accuracy(%)1%
Other featuresPort Height = 12.06 MM
body height40.64 mm
Body length or diameter22.225 mm
shellSTAINLESS STEEL
Number of digits14
Maximum working current3.5 mA
Maximum operating temperature85 °C
Minimum operating temperature-20 °C
Output interface typeI2C INTERFACE
Output typeDIGITAL OUTPUT
Package Shape/FormCYLINDRICAL
port type1/8-27 NPT
Maximum pressure range15000 Psi
Minimum pressure range
Pressure sensing modeCOMPOUND
Response time3000 µs
Sensor/temperature sensor typePRESSURE SENSOR,PIEZORESISTIVE
Maximum supply voltage5 V
Minimum supply voltage2.7 V
Termination typeCABLE
MSP300
Pressure Transducer
SPECIFICATIONS
Analog Output or 14-Bit Digital Pressure with 11-Bit
Temperature Output
One Piece Stainless Steel Construction
Low Cost
17-4PH or 316L Stainless Steel
Customizable
The MSP300
pressure transducer from the Microfused line of TE
is suitable for measurement of liquid or gas pressure, even for
difficult media such as contaminated water, steam, and mildly
corrosive fluids.
FEATURES
One Piece Stainless Steel
Construction
Ranges up to 15kpsi
Digital Pressure and Temperature
Output or Analog mV/Amplified
Output
±1 %Span Accuracy
UL Certification (analog only)
The transducer pressure cavity is machined from a solid piece of
17-4PH or 316L stainless steel. The standard version includes a
1/4 NPT pipe thread allowing a leak-proof, all metal sealed system.
With excellent durability, there are no O-rings, welds or organics
exposed to the pressure media.
TE’s
proprietary Microfused technology, derived from demanding
aerospace applications, employs micromachined silicon
piezoresistive strain gages fused with high temperature glass to a
stainless steel diaphragm. This approach achieves media
compatibility simply and elegantly while providing an exceptionally
stable sensor without the PN junctions of conventional
micromachined sensors.
This product is geared towards industrial and commercial OEMs
for small to high volume applications. Standard configurations are
suitable for many applications. Please contact factory for your
customization needs.
APPLICATIONS
Pumps and Compressors
Hydraulic/Pneumatic Systems
Automotive Test Systems
Energy and Water Management
Medical Gas Pressure
Leak Detection
Remote Measuring Systems
General Pressure Measurements
SENSOR SOLUTIONS
///MSP300
09/2017
Page 1
Repost: Reminiscing the long road of car selection
I started my business in 2007, made my first fortune in 2009, and bought my first car - Bestune B70. Now, Lao Qi has been my Bestune for more than a year. Whenever I need to go on a short business tri...
管家婆啊 Automotive Electronics
Summary of the usage of DSP series software waiting
[size=4]DSP has a fast instruction cycle, so it is necessary to add a wait when accessing slow memory or peripherals. Waiting is divided into hardware waiting and software waiting, and the waiting of ...
Jacktang DSP and ARM Processors
USB HID device development based on LM3S3748
TI only provides USB HID mouse and keyboard routines. Now I want to know how to modify it to a USB HID device (capable of sending and receiving multi-byte data packets) program...
电子猫 Microcontroller MCU
Upload two Chinese materials for learning EAGLE! ~
Students who are interested can download it and have a look. It is said that many enthusiasts abroad use this, and I seem to have heard that several companies in China are using it....
wanghongyang PCB Design
That great guy has jumped through the safeRtos+socket api of LM3s.
I have been adjusting the socket API program of lwip on TI's own operating system SafeRtos these days, and I often get errors. Can you please tell me what I should pay attention to when setting the lw...
confuciounxk Microcontroller MCU
Quartus has a problem, but this works fine
I defined several regs to store several constants, but due to the inconvenience of "addressing", I defined them as storage registers reg [15:0]mem [8:0]; I had never used this type before, so I used a...
eeleader FPGA/CPLD

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1773  1787  1399  1871  2074  36  29  38  42  24 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号