EEWORLDEEWORLDEEWORLD

Part Number

Search

3100-10V6999

Description
TE CONNECTIVITY / PRODUCTS UNLIMITED - 3100-20U18999CL - CONTACTOR DPST-NO-DM; 240VAC; 40A; PANEL
Categorysemiconductor    Analog mixed-signal IC   
File Size158KB,2 Pages
ManufacturerMACOM
Websitehttp://www.macom.com
Download Datasheet View All

3100-10V6999 Overview

TE CONNECTIVITY / PRODUCTS UNLIMITED - 3100-20U18999CL - CONTACTOR DPST-NO-DM; 240VAC; 40A; PANEL

Catalog 1308242
Issued 3-03
PRODUCTS UNLIMITED
Model 96 - 3100
series
Definite Purpose Contactor
1- or 2-pole, 20-40 FLA
AC Coil
File E75492
File EN60947-4-1:1991
IEC 947-4-1
Users should thoroughly review the technical data before selecting a product part
number. It is recommended that users also seek out the pertinent approvals files of
the agencies/laboratories and review them to ensure the product meets the
requirements for a given application.
Features
• Robust 1- and 2-pole contactors.
• Shunt available on 1-pole models.
• Convenient mounting plate.
Environmental Data
Temperature Range:
Storage and Operating: -40°C – +65°C.
Flammability:
UL 94-HB housing.
Mechanical Data
Contact Data @ 25°C
Arrangements:
1 Form X (SPST-NO-DM) with or without shunt and
2 Form X (DPST-NO-DM).
Maximum Ratings:
See Contact Ratings Table.
Material:
Silver Cadmium Oxide.
Contact Termination:
20, 25, 30 FLA Models
Type:
#10-32 Screw with quad 0.250” (6.35 mm) quick connects.
Wire Size:
16-8 AWG (Stranding must be split for 8 AWG wire.)
Tightening Torque:
25 in.-lbs.
40 FLA Models
Type:
Box Lug with dual 0.250” (6.35 mm) quick connects.
Wire Size:
14-4 Cu/Al AWG
Tightening Torque:
40 in.-lbs.
Coil Termination:
Dual 0.250” (6.35 mm) quick connects.
Arc Cover:
Optional on 20-30 FLA models, standard on 40 FLA models.
Weight:
One Pole Types: 8 oz. (227 g) approximately.
Two Pole Types: 9.6 oz. (273 g) approximately
Coil Data @ 25°C
Voltage:
24 - 277 VAC, 50/60 Hz. See Coil Data Table below.
Insulation Class:
UL Class B (130°C).
Duty Cycle:
Continuous.
Contact Ratings
Full
Load
Amps
20
Number
of
Poles
2
Line
Voltage
240/277
480
600
240/277
480
600
240/277
480
600
240/277
480
600
240/277
480
600
240/277
480
600
240/277
480
600
Locked
Rotor
Amps
120
100
80
150
50
40
150
125
100
150
75
50
150
125
100
240
200
160
240
200
160
Resistive
Amps
Rating
30
30
30
30
30
30
35
35
35
40
40
40
40
40
40
50
50
50
50
50
50
Maximum Horsepower
Voltage
Single
Phase
120
2
240
3
120
240
120
240
120
240
120
240
120
240
120
240
1
2
2
3
1
2
2
3
2
3
2
3
25
1
25
2
30
1
30
2
40
1
40
2
Coil Data
Nominal Coil Voltage
Maximum Pickup Volts
Drop-Out Volts Range
Nominal Inrush VA @ 50 Hz
Nominal Inrush VA @ 60 Hz
Nominal Sealed VA @ 50 Hz
Nominal Sealed VA @ 60 Hz
Nominal DC Resistance - Ohms
Dimensions are shown for
24
18
6 - 15
22.5
20
7
5.25
16.5
1-Pole Models
120
88
20 - 70
22.5
20
7
5.25
420
208/240
177
40 - 140
22.5
20
7
5.25
1850
277
221
50 - 165
22.5
20
7
5.25
2650
24
18
6 - 15
37
35
8
7
11
2-Pole Models
120
88
20 - 70
37
35
8
7
250
208/240
177
40 - 140
37
35
8
7
1000
277
221
50 - 165
37
35
8
7
1600
830
reference purposes only.
Dimensions are in inches over
(millimeters) unless otherwise
specified.
Specifications and availability
subject to change.
www.tycoelectronics.com
Technical support:
Refer to inside back cover.
Please tell me the parameters of the diode in the red circle in the figure
I am a newbie, could you please tell me the parameters and function of the diode in the red circle in the picture?...
543794608 Integrated technical exchanges
How can I use C to implement the functions of these 5 lines of code?
I would like to ask how to use C language to implement this assembly function MOV R0, #8 GO: RLC A MOV P3.0, C DJNZ R0, GO unsigned i; sbit P3_0=P3^0; For example, I want to assign each bit of i=0x14 ...
bingyannan Embedded System
Single chip multitasking programming problem
There is a section of code that uses a for loop to initialize an array. If it is placed in the main function, the entire project runs normally. However, if it is placed in the timer initialization fun...
powerfulstyle 51mcu
Introduction to RF and Wireless Technology (Second Edition)
I spent a long time looking for this textbook. It's quite good....
eastman1986 RF/Wirelessly
232 to 485 problem
Can someone help me? I can communicate using the com port to 485, but I can't connect via the USB port to 485, and I can't communicate using the 485 network card directly. Can anyone help me solve thi...
zgy8864 Embedded System
What are the consequences of forgetting to coat copper when making PCB boards?
A few days ago, due to time constraints, I forgot to cover the copper when I handed the PCB to the manufacturer. Now I can't modify it. What are the consequences? Is the impact serious?...
xunxun2012 PCB Design

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2073  560  1619  1804  794  42  12  33  37  16 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号