Strain Guage Sensor, Absolute, -15Psi Min, 135Psi Max, 0.15%, 1-11V, Cylindrical
CategoryThe sensor    Sensor/transducer   
File Size507KB,4 Pages
ManufacturerGems Sensors & Controls
Download Datasheet Parametric View All

2200DA1G5IPA2JB Overview

Strain Guage Sensor, Absolute, -15Psi Min, 135Psi Max, 0.15%, 1-11V, Cylindrical

2200DA1G5IPA2JB Parametric

Parameter NameAttribute value
Is it Rohs certified?incompatible
Reach Compliance Codeunknow
Maximum accuracy(%)0.15%
shellSTAINLESS STEEL
Nominal offset1V
Maximum operating temperature125 °C
Minimum operating temperature-40 °C
Output range1-11V
Output typeANALOG VOLTAGE
Package Shape/FormCYLINDRICAL
port type9/16 MALE
Maximum pressure range135 Psi
Minimum pressure range-15 Psi
Pressure sensing modeABSOLUTE
Sensor/Transducer TypePRESSURE SENSOR,STRAIN GUAGE
Maximum supply voltage35 V
Minimum supply voltage1.5 V
Termination typeDIN 9.4MM W/MATE
Base Number Matches1
RC4 key cracking assistance (chip symmetric encryption key)
We have a chip that has worked fine for several years. Later, the manufacturer stopped supplying it, so we asked someone to get it. When we got it back, we found that it didn't work (we suspected that...
weizhongc Integrated technical exchanges
Share a file to convert hexadecimal code program
In the afternoon, I was debugging the enet_io project discussed by the heroes above. I had no tools to convert web pages and image files to code, so I wrote one myself. It was developed with .NET 2.0,...
fengzhang2002 Microcontroller MCU
Asking for a signal conversion question
I need a circuit now. The input signal is the capacitor charging signal, and the output is the ramp signal of the same time. As shown in the figure, the input signal is the red one, and after passing ...
ncubrian Analog electronics
Renesas R7F0809 used in contrast-induced acute kidney injury risk assessment calculator
I. Basis for the Project Contrast-induced acute kidney injury (CIAKI) is a common complication after interventional surgery. Its occurrence not only prolongs the patient's hospitalization time and inc...
zhangjsh Renesas Electronics MCUs
VC++ Serial Port Debugging Assistant
I hope everyone can help me find the bugNetizens have put forward valuable suggestions. The function of receiving and sending byte statistics has been added. The new version is on the 9th floor. I hop...
william228 MCU
【Design Tools】Xilinx COE File Generation Tool
Xilinx COE file generation tool....
GONGHCU FPGA/CPLD

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 236  590  2915  468  746  5  12  59  10  16 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号