EEWORLDEEWORLDEEWORLD

Part Number

Search

FKP3D011502B00MDSD

Description
Film Capacitor, Polypropylene, 100V, 20% +Tol, 20% -Tol, 0.0015uF, Through Hole Mount, RADIAL LEADED, ROHS COMPLIANT
CategoryPassive components    capacitor   
File Size327KB,8 Pages
ManufacturerWIMA
Websitehttps://www.wima.de/
Environmental Compliance  
Download Datasheet Parametric View All

FKP3D011502B00MDSD Overview

Film Capacitor, Polypropylene, 100V, 20% +Tol, 20% -Tol, 0.0015uF, Through Hole Mount, RADIAL LEADED, ROHS COMPLIANT

FKP3D011502B00MDSD Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerWIMA
package instruction,
Reach Compliance Codecompliant
ECCN codeEAR99
capacitance0.0015 µF
Capacitor typeFILM CAPACITOR
dielectric materialsPOLYPROPYLENE
JESD-609 codee3
Installation featuresTHROUGH HOLE MOUNT
negative tolerance20%
Number of terminals2
Maximum operating temperature85 °C
Minimum operating temperature-55 °C
Package shapeRECTANGULAR PACKAGE
method of packingAMMO PACK
positive tolerance20%
Rated (AC) voltage (URac)63 V
Rated (DC) voltage (URdc)100 V
surface mountNO
Terminal surfaceTin (Sn)
Terminal shapeWIRE
WIMA FKP 3
Polypropylene (PP) Film and Foil
Capacitors for Pulse Applications
PCM 7.5 mm to 15 mm
Special Features
˜
Pulse duty construction
˜
Very low dissipation factor
˜
Negative capacitance change
versus temperature
˜
Very low dielectric absorption
˜
According to RoHS 2002/95/EC
D
Electrical Data
Capacitance range:
100 pF to 0.22
m
F (E12-values on request)
Rated voltages:
63 VDC, 100 VDC, 250 VDC, 400 VDC,
630 VDC, 1000 VDC
Capacitance tolerances:
±20%, ±10%, ±5%
Operating temperature range:
–55+ C to +100+ C
Test specifications:
In accordance with IEC 60384-13
and EN 131 800
Climatic test category:
55/100/56 in accordance with IEC
Insulation resistance
at +20+ C:
5 x 10
5
(mean value: 1 x 10
6
M¸)
Measuring voltage:
U
r
= 63 V: U
test
= 50 V/1 min.
U
r
100 V: U
test
= 100 V/1 min.
Test voltage:
2 U
r
, 2 sec.
Maximum pulse rise time:
1000 V/
m
sec for pulses equal to the
rated voltage
Dielectric absorption:
0.05 %
Temperature coefficient:
–200 x 10
-6
/+ C (general guide)
Dissipation factors
at +20+ C: tan
d
at f
C0.1
mF
0.1
mF
P
C
0.22
mF
3 x 10
-4
6 x 10
-4
Typical Applications
For high frequency applications e.g.
˜
Sample and hold
˜
Timing
˜
LC-Filtering
˜
Oscillating circuits
˜
Audio equipment
1 kHz
4 x 10
-4
10 kHz
5 x 10
-4
100 kHz
10
x 10
-4
Construction
Dielectric:
Polypropylene (PP) film
Capacitor electrodes:
Metal foil
Internal construction:
Voltage derating:
A voltage derating factor of 1.35 % per K
must be applied from +85+ C for DC
voltages and from +75+ C for AC
voltages.
Reliability:
Operational life 300 000 hours
Failure rateP 5 fit (0.5 x U
r
and 40+ C)
Plastic film
Metal foil electrode
Terminating wire
Mechanical Tests
Pull test on leads:
10 N in direction of leads according to
IEC 60068-2-21
Vibration:
6 hours at 10 ... 2000 Hz and 0.75 mm
displacement amplitude or 10 g in
accordance with IEC 60068-2-6
Low air density:
1kPa = 10 mbar in accordance with
IEC 60068-2-13
Bump test:
4000 bumps at 390 m/sec
2
in
accordance with IEC 60068-2-29
Packing
Available taped and reeled.
Detailed taping information and graphs
at the end of the catalogue.
Encapsulation:
Solvent-resistant, flame-retardant plastic
case with epoxy resin seal, UL 94 V-0
Terminations:
Tinned wire.
Marking:
Colour: Red. Marking: Black.
Epoxy resin seal: Yellow
For further details and graphs please
refer to Technical Information.
54
01.10
What are the similarities and differences between conventional PLC and safety PLC?
Safety programmable logic controllers (PLCs) are designed for special-purpose machines and equipment for critical control and safety applications. These controllers are usually part of a safety instru...
plc Industrial Control Electronics
MSP-EXP430G2-LaunchPad Experimenter Board User Guide (Chinese)
MSP-EXP430G2-LaunchPad Experimenter Board User Guide (Chinese)I don't know if anyone has posted this before, haha, if it's a duplicate, please ask the administrator to delete this...
tiankai001 TI Technology Forum
How do I connect the SQLCE of WINCE on the PDA to the SQL on the computer?
I have a SQLCE database on my PDA. I can now use the PULL method in the SQL on my computer to set the parameters to the TRACKINGON method to transfer the table to the SQLCE on the PDA. I can also use ...
fs3328787 Embedded System
Understanding and applying digital-to-analog converters
[b]Some technical indicators of DAC[/b] DAC is the most basic and important mixed signal building block. Its output can be single-ended or differential; the device can be unipolar or bipolar; the tran...
songrisi Analog electronics
Several issues about ADC's iINL and DNL --- as shown in the figure or link https://wenku.baidu.com/view/5e845ffbc...
Several issues about ADC iINL and DNL------as shown in the figure or link https://wenku.baidu.com/view/5e845ffbc8d376eeaeaa31b2.html...
QWE4562009 Integrated technical exchanges
Can you do power consumption design evaluation for AM335X?
My information is all design experience information, which is worth having....
besk DSP and ARM Processors

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1529  546  1814  17  1277  31  11  37  1  26 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号