• Wide operating temperature range from -40°C to +85°C
• UL60950 certified
• IEC/EN60950-1 certified
DC/DC Converter
RKZ-xx2005D
2 Watt
3
SIP7 for
SIC Application
3Y
EAR
wa
The RKZ-xx2005D series features DC/DC converters which are especially designed for SiC mosfet
drivers. The modules are available with input voltages of 5, 12, 15, or 24VDC with two
asymmetric outputs of +20VDC and -5VDC. A special feature of this converter is output power
sharing: the RKZ-xx2005D can be used with equal power (asymmetrical current) or equal current
(asymmetrical power) loads. The modules offer 3kVDC or 4kVDC isolation. The operating
temperature range of -40C to +100°C (with derating) meets harsh environmental requirements.
rranty
Selection Guide
Part
Number
RKZ-052005D
RKZ-122005D
RKZ-152005D
RKZ-242005D
Input
Voltage
(VDC)
5
12
15
24
Output
Voltage
(VDC)
20/-5
20/-5
20/-5
20/-5
Output
Current
(mA)
50/-200
+/-80
50/-200
+/-80
50/-200
+/-80
50/-200
+/-80
Efficiency typ.
typ.
(%)
86
85
86
86
87
max. Capacitive
Load
(1)
(µF)
100/1500
100/1500
100/1500
100/1500
E358085
UL60950-1 certified
CSA C22.2 No. 60950-1-07 certified
IEC/EN60950-1 certified
EN55022 compliant
Notes:
Note1: Max. capacitive load is tested at nominal input voltage and full load.
Model Numbering
RKZ-__2005D/_ _
Input Voltage
Output Voltage
Protection
(3)
Isolation
(2)
Dual
Output
Notes:
Note2: without suffix, standard 3kVDC isolation
add suffix “/H” for higher 4kVDC isolation
Note3: without suffix, without Short Circuit Proetction
add suffix “/P” for continuous short circuit protection
Examples:
RKZ-052005D
RKZ-12005D/HP
=
=
5Vin, 20/-5Vout, without SCP function + standard 3kVDC isolation
12Vin, 20/-5Vout, with continuous SCP function + high 4kVDC isolation
Specifications
(measured at Ta= 25°C, nominal Input and full load after warm-up time unless otherwise noted)
BASIC CHARACTERISTICS
Parameter
Input Voltage Range
Operating Frequency
Minimum Load
Output Ripple and Noise
(4)
Condition
Min.
-10%
20kHz
Typ.
Max.
+10%
0%
70mVp-p
150mVp-p
www.recom-power.com/eval-ref-boards
Notes:
Note4: Ripple and Noise is measured with a 20MHz badnwidth and a 0.1µF ceramic capacitor.
continued on next page
www.recom-power.com
REV.: 3/2017
ECO-1
RKZ-xx2005D
DC/DC Converter
Efficiency vs. Load
100
80
Series
Specifications
(measured at Ta= 25°C, nominal Input and full load after warm-up time unless otherwise noted)
Efficiency [%]
60
40
20
0
5Vin
12Vin
15Vin
24Vin
0
20
40
60
80
100
Load [%]
REGULATIONS
Parameter
Output Voltage Accuracy
Line Voltage Regulation
Load Voltage Regulation
low line to high line, full load and 1%Vin
10% to 100% load
Condition
Values
±5% max.
±1.2% typ.
±5% typ. / ±10% max.
Tolerance Envelope
5Vout
+10%
+10%
Typical Loa
d
20Vout
Output Voltage
+5%
Vnom
+5%
Line
Output Voltage
+5%
+4%
Vnom
Typical Loa
d
Line
-1%
-5%
-0.5%
-5%
10
50
100
10
50
100
Load [%]
Load [%]
PROTECTIONS
Parameter
Short Circuit Protection (SCP)
Isolation Voltage
Isolation Capacitance
Isolation Resistance
ECO-2
REV.: 3/2017
Condition
only with “/P” suffix
I/P to O/P
without suffix
with suffix “/H”
Value
continuous, automatic recovery
3kVDC / 1 second
4kVDC / 1 second
135pF max.
10GΩ min.
www.recom-power.com
RKZ-xx2005D
DC/DC Converter
ENVIRONMENTAL
Parameter
Operating Temperature Range
Operating Humidity
Vibration
MTBF
according to MIL-HDBK-217F
+25°C
+85°C
Series
Condition
free air convection, with derating
non-condensing
Specifications
(measured at Ta= 25°C, nominal Input and full load after warm-up time unless otherwise noted)
Value
-40°C to +100°C
5% - 95% RH max.
MIL-STD-202G
1800 x 10
3
hours
560 x 10³ hours
Derating Graph
(@ nominal Vin at chamber and free air convection)
100
Output Power [%]
80
60
Safe Operating Area
40
20
0
-40
-20
0
20
40
60
80
90
100
120
Ambient Temperature [°C]
85
SAFETY AND CERTIFICATIONS
Certificate Type (Safety)
Information Technology Equipment, General Requirements for Safety
Information Technology Equipment, General Requirements for Safety
RoHs 2
Report / File Number
SPCLVD1602031
E358085
Standard
IEC60950-1, 2nd Edition, 2005
EN60950-1, 2nd Edition, 2006
UL60950-1, 1st Edition, 2007
CAN/CSA C22.2 No. 60950-1-07, 1st Edition, 2006
RoHS 6/6, 2011/65/EU
EMI Compliance
Information technology equipment - Radio disturbance characteristics -
Limits and methods of measurement
Condition
with external filter
Standard / Criterion
EN55022, Class B
EMC filter suggestion for EN55022 Class B
C2
L1
+VIN
C1
+VOUT
MODEL
RKZ-052005D
RKZ-122005D
RKZ-152005D
C1
10µF
4.7µF
4.7µF
2.2µF
C2
L1
4.7µH
22µH
22µH
47µH
Com
470pF, 4kVDC
-VIN
-VOUT
RKZ-242005D
www.recom-power.com
REV.: 3/2017
ECO-3
RKZ-xx2005D
DC/DC Converter
DIMENSION and PHYSICAL CHARACTERISTICS
Parameter
Material
Package Dimension (LxWxH)
Package Weight
Series
Type
Case
Potting
Specifications
(measured at Ta= 25°C, nominal Input and full load after warm-up time unless otherwise noted)
Value
Plastic, (UL94V-0)
Epoxy, (UL94V-0)
19.65 x 7.05 x 10.2mm
2.8g
ebossed logo
Dimension Drawing (mm)
19.6
7.05
0.51
Marking
RKZ-xx2005D/HP
****
10.2
4.10
0.51
Recommended Footprint Details
1 2
5 6 7
1.00 Ø +0.15/-0
1.27
Bottom View
15.24
Top View
2.54
2.0
Pin Connections
Pin #
Dual
1
+Vin
2
-Vin
5
-Vout
6
Com
7
+Vout
Tolerance: xx.x= ±0.5mm
xx.xx= ±0.35mm
Pin:
±0.05mm
INSTALLATION AND APPLICATION
Typical Application Circuit
+Vin
IC1
0.25
2.54
+Vout
DC
+Vin
IC2
C1
DC
-Vin
-Vout
C3
-Vin
IN
IC3
SIC
MOSFET
DRIVER
OUT
+
Q1
D
R3
D1
R4
G
S
D3
SIC Mosfet
Regulator
Signal+ R1
R2
Signal-
OPTO COUPLER
R5
D2
ECO-4
REV.: 3/2017
www.recom-power.com
RKZ-xx2005D
DC/DC Converter
PACKAGING INFORMATION
Packaging Dimension (LxWxH)
Packaging Quantity
Storage Temperature Range
Storage Humidity
Tube
520.0 x 16.5 x 9.3mm
25pcs
-55°C to +125°C
5% to 95% RH
Series
Specifications
(measured at Ta= 25°C, nominal Input and full load after warm-up time unless otherwise noted)
The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The
products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause
loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized
use of RECOM products in such safety-critical applications.
[i=s]This post was last edited by sky999 on 2020-3-30 14:37[/i]According to this circuit, I can't read the remote control signal. VCC is 5V, and pin 5 (DO) is always 2.5V. When the remote control is p...
This car was originally automatic and now it has been changed to manual. But now the line of the mileage meter sensor is gone. Can any master analyze it? Thank you...
Novel Chocolate Flash DriveIt looks very lifelike, and it really looks like chocolate. When using this USB flash drive, keep it away from children. USB flash drive with LCD screenThis product comes wi...
: Process A process is the execution process of a program. The difference between a process and a program: A program is static, it is an ordered collection of instructions saved on the disk, and there...
In early 2002, I started to write a working program for an IC card prepaid electricity meter. The meter used Philips' 8-bit 51-expanded single-chip microcomputer
87LPC764
, and wa...[Details]
The Mobile Industry Processor Interface (MIPI) Alliance is an organization responsible for promoting the standardization of software and hardware in mobile devices. It has released the D-PHY specif...[Details]
All electronic design engineers and scientists have performed electrical signal analysis, or signal analysis for short. Through this basic measurement, they can gain insight into signal details and...[Details]
When choosing a laptop battery, you should consider several factors, such as power, appearance, and quality.
Regarding power, we often see that a manufacturer uses values such as the number ...[Details]
introduction
The emergence of high-performance, low-power embedded CPUs and high-reliability network operating systems has made it possible to implement applications with large amounts of comp...[Details]
1 Introduction
Ultrasonic waves have strong directivity, slow energy consumption, and can propagate over long distances in a medium, so they are used for distance measurement. Ultrasonic detec...[Details]
1. Introduction
At present, most lighting equipment still uses traditional energy for lighting. Making full use of solar energy as the energy supply for lighting equipment is of great si...[Details]
1. System Structure
This system is a simulation system of indoor air-conditioning temperature/humidity control system. The data acquisition and control center collects temperature/humidity...[Details]
Overview:
This paper introduces a method of connecting a CAN-bus network with Ethernet to form a medium-sized remote monitoring/data transmission network.
CAN (Controller Area Network) is ...[Details]
1 Introduction
Water resources are the basic conditions for human survival and the lifeline of economic development. The reality shows that due to the global shortage of water resources and th...[Details]
Many battery-powered systems require a visual indicator to show when the battery needs to be replaced. LEDs are commonly used for this purpose, but they consume at least 10mA of current. This con...[Details]
As a simple and practical input device, buttons have been used in various microcontroller application systems and are ubiquitous. However, the buttons used in different practical occasions are also...[Details]
In today's body control module (BCM) designs, savvy engineers are moving away from electromechanical relays whenever possible. Their next step is to eliminate fuses. But is eliminating fuses a nece...[Details]