EEWORLDEEWORLDEEWORLD

Part Number

Search

DTIPU25B-110

Description
25 Watt Single Output AC/DC Desktop Power Supply
File Size196KB,3 Pages
ManufacturerWall Industries,Inc.
Websitehttps://www.wallindustries.com/
Download Datasheet View All

DTIPU25B-110 Overview

25 Watt Single Output AC/DC Desktop Power Supply

Rev A
DTIPU25 Series
25 Watt
Single Output
AC/DC Desktop Power Supply
FEATURES
Splash Proof
2 Year Warranty
B Type: Class II Insulation
Optional Output Connectors
A & C Types: Class I Insulation
3 Types of Inlet Connectors Available
Approved as Limited Power Source (LPS)
Wide Input Voltage 90~264VAC, 47~63Hz
-20°C~+70°C Operating Temperature Range
Type A
Type B
Type C
DESCRIPTION
The DTIPU25 Series of AC/DC switching mode single output power supplies provides 25 watts of continuous output power. All models have a
single output, universal input voltage range, and an operating temperature range of -20°C ~ +70°C. This series also has three types of AC inlet
connectors to choose from: Type A (IEC-320-C14), Type B (IEC-320-C8), or Type C (IEC-320-C6). All supplies are UL 94V-1 compliant. All models
meet FCC Part-15 class B and CISPR-22 class B emission limits and are designed to comply with UL/cUL (UL 60950-1), TUV/GS (EN 60950-1)
and new CE requirements. All units are Energy Star compliant and 100% burn-in tested.
SPECIFICATIONS:
DTIPU25 Series
All specifications are based on 25°C, Nominal Input Voltage, and Maximum Output Current unless otherwise noted.
We reserve the right to change specifications based on technological advances.
SPECIFICATION
INPUT (V
in
)
Operating Voltage Range
Input Frequency
Input Current (Low Line)
Input Current (High Line)
Inrush Current (Low Line)
Inrush Current (High Line)
Safety Ground Leakage Current
(A & C Types Only)
Safety Ground Leakage Current
(B Type Only)
Start-Up Time
TEST CONDITIONS
Min
90
47
Nom
Max
264
63
0.4
0.25
15
30
0.75
0.25
0.5
Unit
VAC
Hz
A
A
A
A
mA
mA
s
Io = Full Load, Vin = 115VAC
Io = Full Load, Vin = 230VAC
Io = Full Load, 25°C, Cool Start, Vin = 115VAC
Io = Full Load, 25°C, Cool Start, Vin = 230VAC
Io = Full Load, Vin = 240VAC
Io = Full Load, Vin = 240VAC
Io = Full Load, Vin = 100VAC
12
26
0.5
0.15
0.25
OUTPUT (V
o
)
Output Voltage Range
Load Regulation
Line Regulation
Output Power Range
Output Current Range
Ripple & Noise (peak to peak)
Transient Response Time
Hold-Up Time
Vin = 230VAC
Io = Full Load
Vin = 90 to 264VAC
Full Load, Vin = 90VAC
Io = Full Load to Half Load, Vin = 100VAC
Io = Full Load, Vin = 110VAC
1
0
See Rating Chart
3
5
0.5
1
25
See Rating Chart
0.5
1
4
14
16
Nil
110
Io = Full Load, Vin = 230VAC
Primary to Secondary
Primary to Ground
Test Voltage = 500VDC
No Load, Vin = 240VAC
Derate linearly from 100% Load at 40°C to 50% load at 70°C
75
4242
2121
50
0
-20
-40
5
-0.04
0.4
0.5
85
150
95
%
%
W
%
ms
ms
%
%
%
VDC
VDC
MΩ
W
°C
°C
%
%/°C
12
PROTECTION
Over Voltage Protection
Over Current Protection
GENERAL
Efficiency
Dielectric Withstanding Voltage
For Primary to Secondary
Dielectric Withstanding Voltage
For Primary to Ground
(A & C Types Only)
Isolation Resistance
No Load Power Consumption
ENVIRONMENTAL
Operating Temperature
Storage Temperature
Relative Humidity
Temperature Coefficient
MTBF
70
85
95
+0.04
300,000 hours
All Outputs
PHYSICAL
Weight
Dimensions
Input Inlet
Warranty
Approximately 170 grams
A Type:
4.11 x 1.65 x 1.22 inches
B & C Types:
3.90 x 1.65 x 1.22 inches
IEC-320-C14, IEC-320-C8, IEC-320-C6
2 years
Vin = 220VAC
Vin = 110VAC
B
B
Class
Class
SAFETY
CISPR (EMI Requirements for CISPR-22)
FCC (EMI Requirements for FCC Part-15)
Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833
603-778-2300 www.wallindustries.com Fax 603-778-9797
What type of emulator is onboard the CC3200 LAUNCHPAD?
I read the instructions of CC3200 LAUNCHPAD and imported its routines, but I have a question about choosing the simulator. I don't know what simulator it is and which one to choose in the CCS project....
dontium Wireless Connectivity
Problems with returning virtual addresses when using NdisAllocateMemory()
Why is the virtual address returned by NdisAllocateMemory() in the range 0xD000 0000-0xE000 0000? This address space is not defined in g_oalAddressTable and config.bib....
lnsbb2008 Embedded System
LCD multi-level menu display
[i=s] This post was last edited by maclao on 2016-4-15 16:05 [/i] Now I can complete the basic menu operation of the key. I want to add the polling page display when there is no key action. The displa...
maclao 51mcu
Please help, I am a novice
I am not an electronics major, but I work in medical equipment. Due to work needs, I often come into contact with electronics and circuits. Are there any introductory tutorials and books that I can le...
kiolnm Medical Electronics
C Data Structure Information
...
lhx654321 Embedded System
Is there anyone who has done a high frequency injection control algorithm for PMSM?
Some time ago, I made a zero-low speed control simulation of sine wave injection and square wave injection, and recently I want to implement it in code. The code realizes high-frequency injection indu...
jelijck77 Motor Drive Control(Motor Control)

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2632  88  204  803  1304  53  2  5  17  27 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号