Single Output Up to 30 Watts AC/DC Desktop Power Supply

Rev A
DTIPU30 Series
Single Output
Up to 30 Watts
AC/DC Desktop Power Supply
FEATURES
APPLICATIONS
Splash Proof
Scanners
100% Burn-in
LCD Monitors
Class I Insulation
Thermal Printers
IEC-320-C14 Input Inlet
Humidity Temperature Meters
Optional Output Connectors Available
Over Voltage Protection (Crowbar Design)
-20°C ~ +70°C Operating Temperature Range
Wide Input Voltage Range: 90 to 264VAC, 47~63Hz
Input Surge Current, Over Voltage, and Over Load Protection
DESCRIPTION
The DTIPU30 series of AC/DC desktop switching mode power supplies provide up to 30 watts of continuous output power. All models have
a single output, universal input voltage range, and an operating temperature range of –20°C ~ +70°C. These supplies are also protected
against input surge current, over voltage, and over load conditions. All supplies are also UL 94V-1 compliant and include an IEC-320-C14
input connector for worldwide applications. All models meet FCC-Part-15 class B and CISPR-22 class B emission limits and are designed
to comply with UL/c-UL (UL 60950-1), TUV/GS (EN 60950-1), and new CE requirements. These supplies are 100% burn-in tested.
SPECIFICATIONS:
DTIPU30 Series
All specifications are based on 25°C, Nominal Input Voltage, and Maximum Output Current unless otherwise noted.
We reserve the right to change specifications based on technological advances.
SPECIFICATION
INPUT (V
in
)
Operating Voltage Range
Input Frequency
Input Current (Low Line)
Input Current (High Line)
Inrush Current (Low Line)
Inrush Current (High Line)
Safety Ground Leakage Current
Start-Up Time
OUTPUT (V
o
)
Output Voltage
Load Regulation
Line Regulation
Output Power
Output Current
*Ripple
& Noise (peak to peak)
Transient Response Time
Hold-Up Time
Temperature Coefficient
PROTECTION
Over Voltage Protection
Over Current Protection
GENERAL
Efficiency
Dielectric Withstanding Voltage
For Primary to Secondary
Dielectric Withstanding Voltage
For Primary to Ground
Isolation Resistance
ENVIRONMENTAL
Operating Temperature
Storage Temperature
Relative Humidity
MTBF
PHYSICAL
Weight
Dimensions (L x W x H)
Warranty
SAFETY
EMI Requirements for CISPR-22
EMI Requirements for FCC PART-15
TEST CONDITIONS
Min
90
47
Nom
Max
264
63
0.8
0.5
15
30
0.75
2
Unit
VAC
Hz
A
A
A
A
mA
s
VDC
%
%
W
A
%
ms
ms
%/°C
%
%
%
VDC
VDC
MΩ
Io = Full Load, Vin = 115VAC
Io = Full Load, Vin = 230VAC
Io = Full Load, 25°C, Cool Start, Vin = 115VAC
Io = Full Load, 25°C, Cool Start, Vin = 230VAC
Io = Full Load, Vin = 240VAC
Io = Full Load, Vin = 100VAC
Vin = 230VAC
Io = Full Load
Vin = 90 to 264VAC
Full Load, Vin = 90VAC
Io = Full Load to Half Load, Vin = 100VAC
Io = Full Load, Vin = 100VAC
All Outputs
0.3
12
26
0.5
1
See Rating Chart
3
7
0.5
1
0
30
See Rating Chart
0.5
1
4
12
-0.04
+0.04
112
110
132
150
75
85
Io = Full Load, Vin = 230VAC
Primary to Secondary
Primary to Ground
Test Voltage = 500VDC
Derates linearly from 100% Load at 40°C to 50% load at 70°C
Operating Temperature at 25°C, Calculated per MIL-HDBK-217F
65
4242
2121
50
-20
-40
5
+70
+85
95
100,000 hours
°C
°C
%
Approximately 265 ~ 280 grams
4.65 x 2.05 x 1.36 inches
118.0 x 52.0 x 34.5 mm
2 years
Vin = 220VAC
Vin = 110VAC
B
B
Class
Class
*Note: The Ripple & Noise for output voltages under 3.3VDC is 2% max.
Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833
603-778-2300 www.wallindustries.com Fax 603-778-9797
Regarding the battery life of mobile phones,
From nickel-cadmium to nickel-metal hydride to lithium batteries, the battery revolution is encountering bottlenecks due to slow progress in high-density and high-efficiency energy storage media - thi...
qwqwqw2088 Energy Infrastructure?
A new definition of smart community
[align=left]Smart community is not a new concept. According to the different focuses of various industries, smart communities often focus more on the digitization of property-related systems in the co...
3459799010 Industrial Control Electronics
Questions about writing C language programs in CCS environment? ? ? Please help me
I am currently writing a program using a 28035 MCU on the CCS3.3 development platform. I need to convert floating point data into string data, and I found this subroutine in the stdlib.h file of the C...
huwei_harry Microcontroller MCU
About the timer of 51 single chip microcomputer
Let me talk about the functions that my program wants to achieve: the timer 0 of the microcontroller works in counting mode, and the initial value of the counter is set so that a timer interrupt is ge...
chiwawa Embedded System
Siemens/cinterion wireless module information sharing
Siemens/cinterion wireless module information sharing Following TC35i/mc39i/mc55, Siemens/cinterion has launched mc37i/mc52i/mc55i. As a regular agent of Siemens in the Asia-Pacific region (agent cert...
kuaibin2006 RF/Wirelessly
Personal income tax
I am declaring my personal income tax recently. By the way, I want to ask if civil servants and public institution staff have to pay personal income tax. For example, civil servants in first-tier citi...
Fred_1977 Talking

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1776  116  2228  2781  901  36  3  45  56  19 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号