EEWORLDEEWORLDEEWORLD

Part Number

Search

DTIPU45-105

Description
Up to 50 Watts Single, Dual, & Triple Outputs AC/DC Desktop Power Supply
File Size187KB,3 Pages
ManufacturerWall Industries,Inc.
Websitehttps://www.wallindustries.com/
Download Datasheet View All

DTIPU45-105 Overview

Up to 50 Watts Single, Dual, & Triple Outputs AC/DC Desktop Power Supply

Rev. A
DTIPU45 Series
Up to 50 Watts
Single, Dual, & Triple Outputs
AC/DC Desktop Power Supply
FEATURES
Splash Proof
Scanners
Class I Insulation
LCD Monitors
Two Year Warranty
Thermal Printers
IEC-320-C14 Input Inlet
Humidity Temperature Meters
Optional Output Connectors
Single, Dual, and Triple Outputs
Over Voltage Protection (Crowbar Design)
-20°C~+70°C Operating Temperature Range
Wide Input Voltage Range: 90~264VAC, 47~63Hz
Input Surge Current, Over Voltage, and Over Load Protection
APPLICATIONS
DESCRIPTION
The DTIPU45 series of AC/DC switching mode power supplies provide up to 50 watts of continuous output power. Models have a universal
input range and are available with single, dual, or triple outputs. Some features include -20°C ~ +70°C operating temperature and input
surge current, over voltage, and over load protection. All supplies are UL94V-1 compliant and include an IEC-320-C14 input for worldwide
applications. These supplies meet FCC Part-15 class B and CISPR-22 class B emission limits and are designed to comply with UL/c-UL
(UL 60950-1), TUV/GS (EN 60950-1), and new CE requirements. All units are 100% burn-in tested.
SPECIFICATIONS:
DTIPU45 Series
All specifications are based on 25°C, Nominal Input Voltage, and Maximum Output Current unless otherwise noted.
We reserve the right to change specifications based on technological advances.
SPECIFICATION
INPUT (V
in
)
Input Voltage
Input Frequency
Input Current (Low Line)
Input Current (High Line)
Inrush Current (Low Line)
Inrush Current (High Line)
Safety Ground Leakage Current
Start-Up Time
OUTPUT (V
o
)
Output Voltage Range
Load Regulation
Line Regulation
Output Power Range
Output Current Range
*Ripple
& Noise (peak to peak)
Transient Response
Hold-Up Time
PROTECTION
Over Voltage Protection
Over Current Protection
GENERAL
Efficiency
Dielectric Withstanding Voltage
For Primary to Secondary
Dielectric Withstanding Voltage
For Primary to Ground
Isolation Resistance
ENVIRONMENTAL
Operating Temperature
Storage Temperature
Relative Humidity
Temperature Coefficient
MTBF
PHYSICAL
Weight
Dimensions
Warranty
SAFETY
EMI Requirements for CISPR-22
EMI Requirements for FCC PART-15
TEST CONDITIONS
Min
90
47
Nom
Max
264
63
1.35
0.8
15
30
0.75
2
Unit
VAC
Hz
A
A
A
A
mA
s
%
%
W
%
ms
ms
%
%
%
VDC
VDC
MΩ
Io = Full Load, Vin = 115VAC
Io = Full Load, Vin = 230VAC
Io = Full Load, 25°C, Cool Start, Vin = 115VAC
Io = Full Load, 25°C, Cool Start, Vin = 230VAC
Io = Full Load, Vin = 240VAC
Io = Full Load, Vin = 100VAC
Vin = 230VAC
Io = Full Load
Vin = 90 to 264VAC
Full Load, Vin = 90VAC
Io = Full Load to Half Load, Vin = 100VAC
Io = Full Load, Vin = 110VAC
0.3
12
26
0.5
1
0
See Rating Chart
3
15
0.5
1
50
See Rating Chart
0.5
1
4
132
150
83
88
16
112
110
Io = Full Load, Vin = 230VAC
Primary to Secondary
Primary to Ground
Test Voltage = 500VDC
Derate linearly from 100% Load at 40°C to 50% load at 70°C
All Outputs
Operating temperature at 25°C, Calculated per MIL-HDBK-217F
75
4242
2121
50
-20
-40
5
-0.04
70
85
95
+0.04
100,000 hours
°C
°C
%
%/°C
Approximately 535 ~ 560 grams
5.75(L) x 2.99(W) x 1.69(H) inches
146.0(L) x 76.0(W) x 43.0(H) mm
2 years
Vin = 220VAC
Vin = 110VAC
B
B
Class
Class
*Note: The Ripple & Noise for output voltages under 3.3VDC is 2% max.
Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833
603-778-2300 www.wallindustries.com Fax 603-778-9797
How to download programs via serial port on lpc1759
The information says that lpc1759 can use the serial port to download programs, but it cannot be an ordinary three-wire serial port. It must have rts and dtr, but I don't know how to connect them. I d...
jg06 NXP MCU
The webpage cannot be opened normally
Hello, why can't I open the download center?...
linshixiu Suggestions & Announcements
How to open the project file with Keil4?
These .c and .H files belong to the same project. How can I use Keil to directly open the entire project?...
fengchaohao stm32/stm8
How to set the type of member variables to CTime
I want to set the member variable corresponding to the control to CTime, but when using MFC ClassWizard to add a member variable, there is no CTime option in the Variable type option in the Add Member...
monica150373637 Embedded System
Can the blog support Markdown syntax?
I feel that using Markdown syntax is good. It is also very convenient to write. The forum already supports Markdown syntax. Can you also use Markdown syntax in the blog? This way the format is clearer...
chenht7 Suggestions & Announcements
PCB and PCB LAYOUT (dry goods sharing)
...
ylyfxzsx Download Centre

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2568  409  516  33  1737  52  9  11  1  35 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号