EEWORLDEEWORLDEEWORLD

Part Number

Search

SPU50-5

Description
60W Desk Top Switching Power Supplies For I.T.E.
File Size324KB,2 Pages
ManufacturerVolgen
Websitehttp://www.volgen.com/
Download Datasheet Compare View All

SPU50-5 Overview

60W Desk Top Switching Power Supplies For I.T.E.

SPU50 SERIES
60W Desk Top Switching Power Supplies For I.T
.E.
Description:
The SPU50 series of AC/DC switching mode power supplies
provide 60 Watts of continuous output power. All supplies are
UL 94V-0 compliant, include IEC-320-C14 input for
worldwide applications. All models meet FCC Part-15 class B
and CISPR-22 class B emission Limits and are designed to
comply with UL, C-UL, TUV and CE requirements. All units are
100% burned in and tested.
Features:
Wide Input Voltage 90 to 264 VAC,47 to 63 Hz
IEC-320-C14 Input Inlet
Output Voltage Available From 5VDC Thru 50VDC
Optional Output Connector (See appendix)
Input Surge Current, Over Voltage And Over Load protection
Single Output
Splash proof
Class I Insulation
Two years warranty
Safety Approvals :
Electrical Characteristics:
Sym.
Vin
Fin
Wo
Vo
Io
Iil
Iih
Irl
Irh
Eff
CB
Test Conditions
Min.
90
47
Vin=90 to 264VAC
0
Parameter
Input Voltage
Input Frequency
Output Power Range
Output Voltage Range
Output Current Range
Input Current (Low Line)
Input Current (High Line)
Low Line Inrush Current
High Line Inrush Current
Efficiency
Typ.
Max.
264
63
60
Unit
VAC
Hz
W
V
A
A
A
A
A
%
%
%
%
%
mS
mS
See rating chart
See rating chart
Io=Full load, Vin=115VAC
Io=Full load, Vin=230 VAC
Io=Full load, 25°c, Cool start,
Vin=115VAC
Io=Full load, 25°c, Cool start,
Vin=230VAC
Io=Full Load, Vin=230VAC
Io=Full Load
Vin=230VAC
112
110
Io=Full Load to Half Load,Vin=100VAC
Io=Full Load, Vin=100VAC
Io=Full Load, Vin=100VAC
Full Load, Vin=90VAC
Io=Full Load, Vin=240VAC
All output
-0.04
16
0.3
1
0.5
0.5
2
1
0.75
0.04
12
26
75
83
0.5
3
1.6
1.0
15
30
88
1
5
132
150
4
REG-i Line Regulation
REG-o Load Regulation
OVP
OCP
Ttr
Over Voltage Protection
Over Current Protection
Transient Response
Thold Hold-Up Time
Ts
Vrn
Ilk
Tc
Start Up Time
Ripple & Noise (Pe ak to Peak)
Safety Ground Leakage Current
Temperature Coefficient
S
%
mA
%/°c
Environmental :
Sym.
Toper
Tstg
Hr
Pd
Parameter
Operating Temperature
Storage Temperature
Relative Humidity
Test Conditions
Min.
0
-40
5
Typ.
Max.
70
85
95
Unit
°c
°c
%
Derate linearly from 100% load at 40°c to 50% load at 70°c

SPU50-5 Related Products

SPU50-5 SPU50-1 SPU50-1-1 SPU50-2 SPU50-3 SPU50-4 SPU50-6 SPU50-7 SPU50-8 SPU50-9
Description 60W Desk Top Switching Power Supplies For I.T.E. 60W Desk Top Switching Power Supplies For I.T.E. 60W Desk Top Switching Power Supplies For I.T.E. 60W Desk Top Switching Power Supplies For I.T.E. 60W Desk Top Switching Power Supplies For I.T.E. 60W Desk Top Switching Power Supplies For I.T.E. 60W Desk Top Switching Power Supplies For I.T.E. 60W Desk Top Switching Power Supplies For I.T.E. 60W Desk Top Switching Power Supplies For I.T.E. 60W Desk Top Switching Power Supplies For I.T.E.
Discussion on easy-to-error syntax of non-blocking assignment
Please advise everyone! I found that there is a section of the routine in the CD like this: always @(dac_sta or wr_act ) begin dac_load_r <= 1'b1; bit_counter_rst <= 1'b0; dac_sta_next <= dac_idle; ca...
older123 FPGA/CPLD
TI 9B96 development board deadlock problem solution
After using TI development boards for a while , I found that TI chips are easy to lock up. Someone around me has locked up, and many people on the Internet have also locked up. Fortunately, I also had...
youki12345 Microcontroller MCU
Find an ISP expert
I am determined to learn ISP technology, but I know nothing about microcontrollers. I would like to ask for your advice and where should I start. I am sincerely willing to learn from you!...
wo1301 Embedded System
2011 National Competition Retest List
[i=s] This post was last edited by paulhyde on 2014-9-15 03:48 [/i] 2011 National Competition Retest ListQuestion AQuestion CQuestion E[i=s] This post was last edited by paulhyde on 2014-9-15 03:48 [/...
wstt Electronics Design Contest
Ask lanchpad about the default clock
I soldered the 32K crystal oscillator with the lanchpad. The register is in the default state. What are ACLK, MCLK, and SMCLK at this time? ? Thank you. ....
weihei TI Technology Forum
Is there anyone on the forum who has done vector control of high voltage motors?
Discussion on vector control algorithm, everyone is welcome to discuss!...
eeleader Industrial Control Electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1259  984  2010  1369  67  26  20  41  28  2 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号