Available as “HR” (high reliability) screened per MIL-PRF-19500, JANTX level. Add “HR” suffix to base part number.
Available as non-RoHS (Sn/Pb plating), standard, and as RoHS by adding “-PBF” suffix. Part numbers listed indicate a tolerance of ±20% with guaranteed limits on only, VZ, IR and
VF.
Devices with guaranteed limits on all six parameters are indicated by suffix A for ±10% tolerance, suffix B for a ±5% tolerance, suffix C for a 2% tolerance and suffix D for a 1%
tolerance.
MAXIMUM RATINGS
Operating and Storage Temperature
DC Power Dissipation
Power Derating
Forward Voltage @ 200mA
-65°C to + 200°C
500 mW
3.33 mW/C° above 25°C
1.1 Volts
ELECTRICAL CHARACTERISTICS
(T
A
= 25°C unless otherwise specified)
Test
Current
I
ZT
mA
Max Zener Impedance
(2)
A&B Suffix Only
Max Reverse Leakage Current
A, B, & D Suffix
Only
I
R
V
R
µA
@
Volts
A
1N5221
1N5222
1N5223
1N5224
1N5225
1N5226
1N5227
1N5228
1N5229
1N5230
1N5231
1N5232
1N5233
1N5234
1N5235
1N5236
1N5237
1N5238
1N5239
1N5240
1N5241
1N5242
1N5243
1N5244
1N5245
1N5246
1N5247
1N5248
1N5249
1N5250
1N5251
1N5252
1N5253
1N5254
1N5255
1N5256
1N5257
1N5258
1N5259
1N5260
2.4
2.5
2.7
2.8
3.0
3.3
3.6
3.9
4.3
4.7
5.1
5.6
6.0
6.2
6.8
7.5
8.2
8.7
9.1
10
11
12
13
14
15
16
17
18
19
20
22
24
25
27
28
30
33
36
39
43
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
9.5
9.0
8.5
7.8
7.4
7.0
6.6
6.2
5.6
5.2
5.0
4.6
4.5
4.2
3.8
3.4
3.2
3.0
30
30
30
30
29
28
24
23
22
19
17
11
7.0
7.0
5.0
6.0
8.0
8.0
10
17
22
30
13
15
16
17
19
21
23
25
29
33
35
41
44
49
58
70
80
93
1200
1250
1300
1400
1600
1600
1700
1900
2000
1900
1600
1600
1600
1000
750
500
500
600
600
600
600
600
600
600
600
600
600
600
600
600
600
600
600
600
600
600
700
700
800
900
100
100
75
75
50
25
15
10
5.0
5.0
5.0
5.0
5.0
5.0
3.0
3.0
3.0
3.0
3.0
3.0
2.0
1.0
0.5
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.95
0.95
0.95
0.95
0.95
0.95
0.95
0.95
0.95
1.9
1.9
2.9
3.3
3.8
4.8
5.7
6.2
6.2
6.7
7.6
8.0
8.7
9.4
9.5
10.5
11.4
12.4
13.3
13.3
14.3
16.2
17.1
18.1
20
20
22
24
26
29
31
B,C &D
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
2.0
2.0
3.0
3.5
4.0
5.0
6.0
6.5
6.5
7.0
8.0
8.4
9.1
9.9
10
11
12
13
14
14
15
17
18
19
21
21
23
25
27
30
33
Non Suffix
I
R
@ V
R
Used For
Suffix A
µA
200
200
150
150
100
100
100
75
50
50
50
50
50
50
30
30
30
30
30
30
30
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
Max Zener Voltage
Temp. Coeff.
(A&B Suffix Only)
α
VZ
(%/°C)
(3)
-0.085
-0.085
-0.080
-0.080
-0.075
-0.070
-0.065
-0.060
±0.055
±0.030
±0.030
+0.038
+0.038
+0.045
+0.050
+0.058
+0.062
+0.065
+0.068
+0.075
+0.076
+0.077
+0.079
+0.082
+0.082
+0.083
+0.084
+0.085
+0.086
+0.086
+0.087
+0.088
+0.089
+0.090
+0.091
+0.091
+0.092
+0.093
+0.094
+0.095
Part Number
(1)
Nominal
Zener Voltage
V
Z
@ I
ZT
Volts
Z
ZT
@ I
ZT
Ohms
Z
ZT
@ I
ZK
=0.25mA
Ohms
Rev. 20120712
High-reliability discrete products
and engineering services since 1977
1N5221-1N5281
SILICON ZENER DIODES
Max Zener Impedance
A&B Suffix Only
(2)
I
R
µA
Max Reverse Leakage Current
A, B, & D Suffix
Only
V
R
@
Volts
A
B,C&D
36
39
43
46
47
52
56
62
68
69
76
84
91
99
106
114
122
129
137
144
152
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
+0.095
+0.096
+0.096
+0.097
+0.097
+0.097
+0.098
+0.098
+0.099
+0.099
+0.110
+0.110
+0.110
+0.110
+0.110
+0.110
+0.110
+0.110
+0.110
+0.110
+0.110
Non Suffix
I
R
@ V
R
Used For
Suffix A
µA
Max Zener Voltage
Temp. Coeff.
(A&B Suffix Only)
α
VZ
(%/°C)
(3)
Part Number
(1)
Nominal
Zener Voltage
V
Z
@ I
ZT
Volts
Test
Current
I
ZT
mA
Z
ZT
@ I
ZT
Ohms
105
125
150
170
185
230
270
330
370
400
500
750
900
1100
1300
150
170
190
2200
2400
2500
Z
ZT
@ I
ZK
=0.25mA
Ohms
1000
1100
1300
1400
1400
1600
1700
2000
2200
2300
2600
3000
4000
4500
4500
5000
5500
5500
6000
6500
7000
1N5261
1N5262
1N5263
1N5264
1N5265
1N5266
1N5267
1N5268
1N5269
1N5270
1N5271
1N5272
1N5273
1N5274
1N5275
1N5276
1N5277
1N5278
1N5279
1N5280
1N5281
47
51
56
60
62
68
75
82
87
91
100
110
120
130
140
150
160
170
180
190
200
2.7
2.5
2.2
2.1
2.0
1.8
1.7
1.5
1.4
1.4
1.3
1.1
1.0
0.95
0.90
0.85
0.80
0.74
0.68
0.66
0.65
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
34
37
41
44
45
49
53
59
65
66
72
80
86
94
101
108
116
123
130
137
144
NOTE 1: The electrical characteristics are measured after allowing the device to stabilize for 20 seconds when mounted with a 3/8” minimum lead length from the case.
NOTE 2: The zener impedance is derived from the 60HZ ac voltage, which results when an ac current having an r.m.s. value equal to 10% of the DC zener current
(I
ZT
or I
ZK
) is superimposed on I
ZT
or I
ZK
. Zener impedance is measured at two points to insure a sharp knee on the breakdown curve, thereby eliminating unstable units.
NOTE 3: Temperature coefficient (α
VZ
). Test conditions for temperature coefficient are a follows:
a.
I
ZT
= 7.5 mA, T
1
= 25°C,
T
2
= 125°C (1N5221A, thru 1N5242A, B.)
b.
I
ZT
= Rated I
ZT
, T
1
= 25°C,
T
2
= 125°C (1N5243A, B thru 1N5281A, B.)
Device to be temperature stabilized with current applied prior to reading breakdown voltage at the specified ambient temperature.
[i=s]This post was last edited by yangxz on 2022-5-9 14:37[/i][RVB2601 Creative Application Development] + Smart SwitchProject Background ( 100-200words )Today, smart home applications are widely used...
[size=12px]RB4, RB3, RB2 are set as ports and analog input is set. Channels are also selected as AN4, AN3, AN2. The trigger signal is global software edge trigger. The ADC function is also enabled, bu...
The purpose and function of each layer of PADS--Ye Mao PCB Studio
TOP Top layer for routing and placing components BOTTOM Bottom layer for routing and placing components LAYER-3 to LAYER-120 Ordinary ...
Project: Power Meter
Background: The company already has instruments with MSP430 as the controller. On this basis, the main control chip is replaced with LPC1100 series controller to improve performan...
[i=s]This post was last edited by elvike on 2017-1-13 00:43[/i] I have never had the concept of version management. I would save files every day after making certain progress. As a result, more and mo...
In the motor control, TIM1 is used for 50us timing, USART1 interrupt is used to communicate with PC, the USART1 interrupt program receives data from PC and the timing interrupt generates PWM correctly...
PV DC fuses are safety devices used to protect PV panels, inverters, and DC loads. To ensure their safety and reliability, they must be UL248 certified.
Before applying for UL248 certifi...[Details]
Abstract:
With the increasing complexity of smart vehicle electrical and electronic architectures, the full lifecycle management of vehicle electronic control components faces multiple challe...[Details]
The problem of dynamic sealing of equipment always exists with the operation of the equipment. Today, we have specially sorted out the various commonly used sealing forms, usage scope and character...[Details]
Electric vehicles are currently gaining momentum, but this is just a facade. Fuel-powered vehicles remain unchallenged. While electric vehicles boast unique advantages in environmental emissions an...[Details]
With the rapid advancement of automation technology, collaboration between robots is no longer just science fiction. Imagine dozens of machines moving goods in a warehouse without interfering with ...[Details]
introduction
The concept of the smart home is gradually developing and gaining market acceptance. We believe its ultimate form lies in the interconnection of all home appliances through open i...[Details]
With the continuous development of the industrial automation industry, we are seeing an increasing number of intelligent devices using flexible, efficient, and precise robotic arms to p...[Details]
In daily life, power transformers have different functions and uses due to different usage scenarios. The most common ones can be divided into: control transformers, isolation transformers, rectifi...[Details]
The MCX E series is the most reliability- and safety-focused series in NXP's extensive MCX product portfolio.
With the launch of this series, NXP has further enriched its 5V-compatible MCU pr...[Details]
In the period after the switching power supply achieved the "20 kHz" revolution in the 1970s, although improvements and enhancements were made in circuit technology, the development level of the se...[Details]
Methods of DC motor speed regulation:
1. The voltage regulator can be used to change the input voltage and speed directly, which is often used for large kilowatt-level motors.
2. Thyristo...[Details]
Common methods for troubleshooting roller press bearing wear include repair welding, thermal spraying, brush plating, and scrapping and replacement. However, these methods are often subject to asse...[Details]
With the gradual popularization of new energy vehicles in recent years, more and more people have been able to access and purchase electric vehicles. The structure of electric vehicles is composed ...[Details]
On August 21, it was reported that Intel's new generation of AI chip Jaguar Shores was recently exposed for the first time.
According to photos shared by Andreas Schilling, the Jaguar Shores t...[Details]
Wearable technology is taking off, with applications evolving rapidly, from smartwatches to fitness trackers and even smart wigs! Bluetooth Smart is at the center of this revolution. This is the se...[Details]